Loading...
HomeMy WebLinkAbout0252_250250 at Alley pavements shall be a minimum of twelve feet in width of flexible base six inches thick, and a single course inverted penetration topping or equal. d. ,"here a public sanitary sewer is reasonably accessible, each lot within a subdivided area shall be provided with a connection to such sanitary sewer. The minimum size for mains shall be approved by the City Managero y4hen any subdivision is planned that is not reasonably accessible to a public sanitary sewer, it shall provide either for the use of septic tanks or an individual sewage treatment plant as followss (1) Septic Tanks In all subdivisions planned for septic tank use the minimum lot area shall be twelve thousand square feet per single family dwelling* peptic tanks shall be installed on each lot concurrent with any development thereon and the design of such system and the method of installation shall conform in all respects to the requirements of the City health Officer and the Public Health Service Publication No. 526. The City Health Officer shall have the authority to vary the lot area re- quirement where satisfactory and evidence is presented indicating that soil conditions are such as to warrant a modification. (2) Individual Sewage Treatment Plantes In all subdivisions planned to be serviced by an individual sewage treatment plant, lots may be of standard area and sewers shall be installed to serve each lot. The Plant providing such sewage disposal facilities shall be constructed in accordance with the regulations and requirements of the State Board of Heilth and the approval and under the supervision of the City Health Officer and the City Manager. e. Nater Liness (1) Nhere an approved public water supply is reasonably accessible or.procurgble, each lot within the subdivided area shall be provided with access to such water supply. The layout shall be designed to form a loop system. No main shall be smaller than vix inches and the minimum size for service lines shall be two inches, stubs may be extended to serve a maximum of twenty lots. (2) In areas where a public water supply is not available, the subdivider shall construct wells in such a manner than an adequate supply of potable water shall be available to every lot in -.the subdivision. Such water supply system shall be constructed under the supervision of the City Health Officer and shall comply with all regulations of the 6tate Board of Health in regard to such system, as well as providing pipe sizes and layout requirements of Paragraph (1) above. f. Utility Lines, Where it shall be determined by the City Manager that larger mains or lines are required in order to provide for the future, extension of the utility system beyond the limits of the subdivision in question, the City shall assume the responsibility for any additional cost. g. Drainage shall be provided by surface construction as approved by the City Manager. h, In the area outside the one and one-half mile boundary and within the 5 _ mile area, curbs, gutters, and sidewalks may be eliminated. VI. PLATS A0 DATA A. Preliminary Plate and Data for Conditional Approvalt The preliminary plat shall be drawn on a scale of one hundred feet to the inch or larger and shall show the following. 1. The title, north point, direction of prevailing breeze, scala and date, 2. The name of the owner or owners and the engineer or surveyor.