HomeMy WebLinkAbout0217_21221.2
Section 2. Of this Amendment
Section 12.1.4 "MATERIALS AND USES:" is hereby amended so as to include
within the uses permitted for "plastic pipe, minimum schedule 40" shall be
as follows:
Building Sewer, Outside
Building Drain
Soil Stack
Drainage Branches
Vent Stack
Vent Branches
Building to Storm Sewer
Building to Storm Drain
Special Wastes
Indirect Wastes
Section 3. of this Amendment
Chapter 22 "GAS PLUMBING", Sub -section 22.2.2 under General Regulations
captioned "Outside Gas Lights" is hereby amended to read as follows:
22.2.2 Outside Gas Lights: Type "K" copper tubing may be used for
underground piping in outside gas light installation. Polyethylene
plastic pipe or tubing conforming with specification ASTtI D2513-67
Standards Specification for Thermoplastic gas pressure pipe,
tubing and fittings, may also be used for conveying natural gas
underground to outside appliances such as gas lights and grills.
The material shall be Polyethylene, Type III Grade 3 Class C
(PE3306) and Type II, Grade 3 Class B (PE2306), ASTM Stand D1248-68.
Said materials shall be installed in accordance with ANSI Standard
Code for pressure piping B31.8-1968 Edition.
Section 4. of this Amendment
If any provision of this Amendment to the Plumbing Code, or the application
thereof to any person or circumstances, is held invalid, the remainder of
this amendment, and the application of such provisions to other persons
or circumstances, shall not be affected thereby. All ordinances or portions
of ordinances in conflict' herewith are hereby repealed.
PASSED AND APPROVED this 10th day of August, 1970.
ATTEST:
Claud Eads, City Secretary
Jay C. Sloan, Mayor, City of Georgetown