HomeMy WebLinkAbout0130_0016Section 191-8 'Every building hereafter erected,
altered or enlarged within the Fire Limits, shall be en-
closed on all sides with walls constructed wholly of stone,
well burned brick, or reinforced concrete, and shall have
the roof, also the roof and sides of all roof strictures,
covered with incumbustible material.
All cornices shall be of incombustible material.
Section 191-0 No structure whose walls are wholly,
or in part, constructed of wood, shall, hereafter, be built
or moved into the Fire Limits as herein designated or as
they may hereafter be established, except as follows:
(A) Temporary one story frame buildings for use of
builders.
(B) Small outhouses not exceeding 100 square feet in
area and 8 feet in height, not located within 30 feet of any
other building, nor within 5 feet of any lot or line.
Any existing frame or iron-cl&d building within the
Fire Limits, which may hereafter be damaged by fire, decay,
or otherwise# to an amount greater than one half its present
value exclusive of the foundation shall not be repaired or
rebuilt, but shall be removed.
Section 191-D Gas connections to stove and similar
heating devices shall be made of rigid metal pipes. For small
portable gas heating devices, flexible metal or rubber tubing
may be used when there is no valve or other shut-off on the
device.
Section 191-E That this Ordinance shall be cumulative
of all other ordinances heretofore pa,sed on this subject,
except wherein it conflicts with them, in which event this
ordinance shall govern.
PAS= duly 14th, 1930.
ATTEST: M.L. Cates,
Secretary,
M.F. Smith,--
Llayor.
1930
11