HomeMy WebLinkAbout0088_0002/ C. Horn Court exceeds 600' maximum length for cul-de-sac and should be connected to Snyder Court and the request for variance not granted. Similar redesign should be considered for Hyer Court and Merritt Court. IV. Recommend providing street access to adjacent properties to the north, east and southeast. V. Variance must be requested and justified for proposed reduction of off-street parking re- quirements for three bedroom units. VI. Additional water storage facilities are re- quired to adequately accommodate the development. VII. Water Availability Note shall apply to this subdivision (ie. No building permits shall be issued until the proposed water treatment facil- ities are operational or an acceptable alternate source is provided.). VIII. The preliminary site plan and/or support docu- ments should provide all informational require- ments of Section 2.809 of P.U.D. Ordinance. IX. The site plan, typical lot layout, and archi- tectural illustrations should be co-ordinated to provide an accurate indication of all facets of the development. X. A landscape plan should be submitted. RECOMMENDATION: The plat and site plan should be resubmitted with all informational requirements of the P.U.D. Ordinance met and the above comments satisfied. N