Loading...
HomeMy WebLinkAboutORD 08.10.1970 - Plumbing Code AmendmentMP411 A'NT A),1014DINIENIT TO TIM PLUMBING CODE OF THE CITY OF GEOIIIGEXOWNT, Tl,,V'iliS, AMENDING CHAPTER 12 BY ADDING A NEW SECTION, 12.1.3.11 AMENDING SECTION 12.1.4 AND AMENDING CIL4PTE'R 22, SECTION 22.2.2 BE 11' ORDAINED that the Plumbing Code of the City of Georgetowny Texas; en- acted October 141 1963, is hereby amended as follows: Section 1. of this amendment Chapter 12 of said Plumbing Code, "MATEUIALS - QUALITY AND WEIGHT" is hereby amended by adding thereto the following: "12.1.3.1 Nothwithstanding anything in said Plumbing Code it is pereby provided that plastic pipe and fittings may .be installed as hereinafter provided and3such pipe and fittings shall be approved by the City Council acting by and through its plumbing inspector. Such plastic pipe may be used for drain, waste, vents, building and/or house sewers, indirect waste and storm drains, throughout all types of buildings. Such pipe shall be schedule 40 AIB36 or PVC, 1AVV as specified in Commercial Standard 270-65 or 272-65. Pipe and fittings shall be identified as provided in the above. Standard and shall bear the seal of the National Sanitation Foundation. Pipe for storm drains and indirect wastes will meet the requirements of CS 207-60 for PV& or CS 218-59 for ABS,j All plastic pipe and fittings shall be marked as follows: Manufacturer's Name I'VE-1-Schedule 40-CS-272-65-NSF-DWV Fittings PVC-l-NSF-1DfW111AT ABS Schedule 40-CS-270-65-NSF-DUN All'S, Fittings 40-CS-27O-65&NSF-13WV Markings shall be visible for inspection on both Pipe and Fittings of PVC and ABS All underground piping within buildings shall be imbedded in six (6) C-7 inches of sand below, above, and to both sides of the pipe. The Plumbing Inspector of the City of Georgetown may determine at any time if additional. protection is necessary. Such pipe materials shall be used in accordance with manufacturers' recommended practices and procedures, but in no case shall they be less restrictive than as outlined in Commercial Standard 272-65-270-65 or the recommendations of the National Sanitation Foundation Standards. Provisions of the expansion and support of the pipe shall be as recommended by these standards.'' 212 Section 2. Of this Amendment Section 12.1.4 "MATERIALS AND USES:" is hereby amended so as to include within the uses permitted for "plastic pipe, minimum schedule 40" shall be as follows: Building Sewer, Outside Building Drain Soil Stack Drainage Branches Vent Sack Vent Branches Building to Storm Sewer Building to Storm Drain Special Wastes Indirect bastes Section 3. of this Amendment Chapter 22 "GAS LU1 L`dG", Sub -section 2.2.2 under General Regulations captioned "Outside Gas Lights" is hereby amended to read as follows: 22.2.2 Outside Gas Lights: Type "K" copper tubing may be used for underground piping in outside gas light installation. Polyethylene plastic pipe or tubing conforming with specification AS UM D23-67 Standards Specification for Thermoplastic gas pressure pipe, tubing and fittings, may also be used for conveying natural gas underground to outside appliances such as gas lights and grills. The material shall be Polyethylene, Type III Grade 3 Class C (PE3 06) and'Type II, Grade 3 Class B (PE2306), ASTM Stand D1 48-68. Said materials shall be installed in accordance with -ANSI Standard Code for pressure piping B 3 .8-1968 Edition. Section 4. of this Amendment If any provision of this Amendment to the Plumbing Code, or the application' thereof o any person or circumstances, is held invalid, the remainder o this amendment, and the application of such provisions to other persons or circumstances, sall not be affected thereby. All ordinances or portions of ordinances in conflict". herewith are hereby repealed. PASSED AND APPROVED this 10th day of August, 1970. A TTL 'T: Jay C. Sloan, Mayor, City of Georgetown Claud Es, City Secretary