Loading...
HomeMy WebLinkAboutAgenda_P&Z_12.06.2016Notice of Meeting for the Planning and Zoning Commission of the City of Georgetown December 6, 2016 at 6:00 PM at 101 E. Sev enth Street, Georgetown, Texas 78626 The City o f G eo rgeto wn is committed to comp lianc e with the Americans with Dis abilities Ac t (ADA). If yo u req uire as s is tanc e in participating at a p ublic meeting d ue to a disability, as d efined und er the ADA, reas onab le as s is tance, ad ap tatio ns , or acc o mmo d ations will b e provid ed up o n req uest. P leas e c o ntact the City Sec retary's Office, at leas t three (3) days prior to the sc hed uled meeting d ate, at (512) 930-3652 o r City Hall at 113 Eas t 8th Street fo r add itional info rmation; TTY us ers ro ute through Relay Texas at 711. Call to O r de r P le dge of All egi anc e Comme nts fr om the Chair - We lc ome and M ee ting P r oce dur e s Action fr om Exe cutive Session As of the de adli ne , no per sons we r e si gne d up to spe ak on i tems other than those poste d on the agenda. Consent Agenda The Statutory Cons ent Agenda inc ludes non-c o ntro versial and ro utine items that may be acted up o n with one s ingle vo te. An item may b e pulled from the Cons ent Agenda in o rd er that it b e dis c us sed and acted up o n individ ually as part of the Regular Agenda. A Co nsideration of the Minutes from the Novemb er 1, 2016 P &Z meeting. Karen Frost, Rec o rd ing Secretary Legislativ e Regular Agenda B Public Hearing and possible actio n o n a Replat of a Final Plat, being 5 ac res of Whitetail Sec tion 2, Lo t 37, loc ated at 406 Doe Run. (FP-2016-019) Juan Enriq uez, Planner C Public Hearing and possible actio n o n a req ues t to Rezone Lot 1, Bloc k F, S ummit at Rivery Park Phases 5 & 6, lo cated at 1101 Woodlawn Avenue to amend the Summit at Rivery Park P lanned Unit Development (P UD) Dis tric t. (REZ-2016--027, Sheraton Georgetown) Valerie Kreger, AICP, Principal Planner D Public Hearing and possible actio n o n a req ues t to Rezone ap p ro ximately 78.29 ac res in the Ad d is on Survey, loc ated near the intersec tion of Inner Loop and East Univers ity Avenue. (REZ-2013-016, Georgetown 120 Ho ld ings ) Jo rd an Maddox, AICP, Principal Planner E Dis cus s ion Items : Update on the Unified Development C o d e Advis o ry Committee (UDC AC ) meetings . (Commis s ioner Bargainer) Update on the Geo rgeto wn Transp o rtatio n Ad visory Board (GTAB) meetings . Page 1 of 80 Ques tio ns o r c o mments from Commis s io ners-in-Training about the ac tio ns and matters c o nsidered on this agenda. Remind er of the next P lanning and Zoning Co mmis s io n meeting on December 20, 2016 at Co unc il Chamb ers loc ated at 101 East 7th Street, s tarting at 6:00 p m. Adjournment CERTIFICATE OF POSTING I, Shelley No wling, C ity S ecretary fo r the C ity of Geo rgeto wn, Texas , d o hereby c ertify that this Notice of Meeting was p o s ted at City Hall, 113 E. 8th Street, a p lace read ily acc es s ible to the general p ublic at all times , on the ______ d ay o f __________________, 2016, at __________, and remained so p o s ted fo r at leas t 72 c o ntinuo us ho urs p receding the sc heduled time o f s aid meeting. ____________________________________ S helley No wling, City Sec retary Page 2 of 80 City of Georgetown, Texas Planning and Zoning December 6, 2016 SUBJECT: Cons id eration o f the Minutes fro m the November 1, 2016 P&Z meeting. Karen F ro s t, Recording Sec retary ITEM SUMMARY: FINANCIAL IMPACT: NA SUBMITTED BY: ATTACHMENTS: Description Type P&Z Minutes _11.01.2016 Backup Material Page 3 of 80 P&Z Minutes Page 1 of 4 November 1, 2016 City of Georgetown, Texas Planning and Zoning Commission Meeting Minutes Tuesday, October 4, 2016 at 6:00 PM Council and Courts Building 101 East 7th Street, Georgetown, Texas 78626 Commissioners present: Josh Schroeder, Chair; Kevin Pitts, Vice-Chair; Tim Bargainer, Alex Fuller and Andy Webb Commissioner(s) Absent: John Marler Commissioners in Training: Gary Leissner, Aaron Albright Commissioner(s) in Training Absent: na Staff Present: Sofia Nelson, Planning Director; Valerie Kreger, Principal Planner; Jordan Maddox, Principal Planner; Juan Enriquez, Planner; Carolyn Horner, Planner; Matt Synatschk, Planner; and Karen Frost, Recording Secretary. A. Chair Schroeder called the meeting to order at 6:00 p.m. and lead the Pledge of Allegiance. Chair Schroeder stated the order of the meeting and that those who speak must turn in a speaker form to the recording secretary before the item that they wish to address begins. Each speaker is permitted to address the Commission once for each item, for a maximum of three (3) minutes, unless otherwise agreed to before the meeting begins. B. As of the deadline for this agenda, no persons were signed up to speak on items other than what was posted on the agenda. Consent Agenda The Statutory Consent Agenda includes non-controversial and routine items that may be acted upon with one single vote. An item may be pulled from the Consent Agenda in order that it be discussed and acted upon individually as part of the Regular Agenda. C. Consideration of the Minutes from the October 18, 2016 P&Z meeting. Stephanie McNickle, Recording Secretary Motion by Commissioner Pitts to approve the consent agenda including the minutes from the October 18, 2016, Planning and Zoning meeting. Second by Commissioner Bargainer. Approved 5 – 0 – 1 (Marler absent) Legislative Regular Agenda D. Public Hearing and possible action on a request to Rezone approximately 74.415 acres of the David Wright survey located at 2101 Airport Road from C-3 General Commercial to IN Industrial. (REZ-2016-030, Project Cat) Sofia Nelson, Planning Director Nelson presented the staff report. This rezoning matches the Future Land Use Plan and staff recommends approval. The Public Hearing was opened and closed with no speakers coming forth. Motion by Pitts, second by Fuller to recommend approval to the City Council for the rezoning. Motion approved 5 – 0 – 1 (Marler absent) Page 4 of 80 P&Z Minutes Page 2 of 4 November 1, 2016 E. Public Hearing and possible action on a request to Rezone 3.5 acres of San Gabriel Estates, Block 1, Lot 22A located at 700 Booty’s Crossing Road from the Agriculture (AG) District to the Neighborhood Commercial (CN) District. (REZ-2016-024, Faith Impact Church) Juan Enriquez, Planner Enriquez presented the staff report. He stated a tree survey will be required for the Site Plan review. Staff recommends approval. The Public Hearing was opened and closed with no speakers coming forth. Motion by Fuller, second by Webb to recommend approval to the City Council for the rezoning. Motion approved 5 – 0 – 1 (Marler absent) Item I was taken here, out of order by action of the Chair. See action below. At the end of Item I, Chair Schroeder left the dais and the meeting declaring a conflict of interest on the remaining items. Vice-Chair Pitts ran the remainder of the meeting. F. Public Hearing and possible action on a request to Rezone approximately 83.5 acres in the W. Roberts Survey located north of Fairway Lane and south of Shell Road, from the Agriculture (AG) District to the Residential Single-Family (RS) and Local Commercial (C-1) Districts. (REZ-2016-025, Hidden Oaks at Berry Creek) Carolyn Horner, AICP, Planner Horner presented the staff report, stating the proposed zoning district matches the Future Land Use Plan and recommending approval. She also stated that there will be Hwy 195 access to the residential and commercial portions of the subdivision. Vice-Chair Pitts opened the Public Hearing. Gary Starzinski of 30305 St. Andrews had questions about the development and concerns about the flood control and types of housing being proposed that could possibly affect their property values. Ercel Brashear of 30401 St. Andrews stated he feels the zoning request is appropriate for the area but wants resolution of the existing and future water issues. He showed a video clip of rushing water through the neighborhood from a heavy rain event. He wants to go on record with his concerns and direction to be given to staff to work to alleviate this problem. Paul Nelson of 30308 St. Andrews spoke concerning the flooding issues, stating that the video showed one event, but that they seem to be getting worse with each storm. He appreciates the development of quality homes but says there needs to be some way to move the water across the land in a more efficient way without washing away their properties. The public hearing was closed with no more speakers. Tim Moltz, the engineer for the applicant spoke to the concerns. He stated the developer is providing water quality and detention ponds and are working on the storm water to be taken out Fairway Lane to St. Andrews and downstream, all underground and reducing the amount of sheet flow on those streets. He also stated the construction access for Phase 1 of this subdivision would come from Shell Road and for Phase 2 would come from Hwy 195. No access would be driving through Berry Creek subdivision. David Munk, the city Development Engineer stated that he had worked with TxDot to Page 5 of 80 P&Z Minutes Page 3 of 4 November 1, 2016 address the water issues. According to reports from TxDOT, the runoff was not caused by Hwy 195. There was further discussion by the Commissioners and Munk stated he would continue to work with the neighborhood. He assured the commission that the new developer would be taking care of their own storm water runoff. The preliminary plat will come to the commission for further review in the future. Motion by Bargainer, second by Fuller to recommend approval to the City Council for the rezoning. Approved 4 – 0 – 2 (Marler absent and Schroeder recused.) G. Public Hearing and possible action on a request to Rezone approximately 10.058 acres in the Frances A Hudson Survey located at 555 Rabbit Hill Road from the Agriculture (AG) District to the Business Park (BP) District. (REZ-2016-026, Enterprise Pipeline) Matt Synatschk, Planner Synatschk presented the staff report stating the Business Park zoning district would allow the variety that is sought for this use and provide a buffer between the I35 commercial districts and the residential districts to the east. Staff recommends approval of this application. Vice-Chair Pitts opened the Public Hearing. Brett Miler, 4310 Highway 29 west, owns the adjacent property and is concerned not only about his property values, but the health and safety of having a pump station in the city limits. He is concerned about the aesthetics and the noise that are associated with a pump station. Vice-Chair Pitts closed the Public Hearing with no other speakers coming forth. Jordan Maddox addressed the concerns of the speaker. He explained that when the applicant first came in, the property was not in the city limits, but that it was annexed in for the city to have controls over the zoning and development of the property. The developer of this property purchased extra acres to provide greater setbacks, is providing a housing structure for the pumps, is adding a large landscape buffer to alleviate noise and site issues and is developing above and beyond the code standards. Motion by Bargainer, second by Webb to recommend approval to the City Council for the rezoning. Approved 4 – 0 – 2 (Marler absent and Schroeder recused.) H. Public Hearing and possible action to Rezone Lot 1, Block F, Summit at Rivery Park Phases 5 & 6, located at 1101 Woodlawn Avenue to amend the Summit at Rivery Park Planned Unit Development (PUD) District. (REZ-2016-027, Sheraton Georgetown) Valerie Kreger, AICP, Principal Planner This item was pulled by staff. I. Public Hearing and possible action on a request to Rezone approximately 165.65 acres described as 142.80 acres in the N. Porter and A. Flores Surveys, 0.68 acres, 5.07 acres, and 12.31 acres in the N. Porter Survey and 4.79 acres, being Blocks 1 – 3 of the North Georgetown Additions, located between Austin Ave. and N. College St. south of FM 971, from the Residential Single-family (RS) and Local Commercial (C-1) Districts to the Public Facilities (PF) District. (REZ-2016-029, San Gabriel Park) Valerie Kreger, AICP, Principal Planner Page 6 of 80 P&Z Minutes Page 4 of 4 November 1, 2016 Kreger presented the staff report and application. The public park is being rezoned as a “housekeeping” item to bring the park into compliance with the current use. It received the RS zoning district as a default zoning district many years ago and with future updates to the park being funded and planned, the zoning district needs to be consistent with the use. Staff is recommending approval of the rezoning. Schroeder asked if there would be any impact on existing businesses that serve or sold alcohol. Kreger responded that the uses in place in and around the park would not be changed. Chair Schroeder opened the public hearing. Jennifer Gwinn of 803 N. Myrtle St. had questions about the effect of the changes on her property that backs up to a section of the park. She was directed to talk to staff separately regarding her specific questions. The Public Hearing was closed with no other speakers coming forth. Motion by Bargainer, second by Fuller to recommend approval to the City Council for the rezoning. Motion approved 5 – 0 – 1 (Marler absent) J. Presentation and Discussion on Williams Drive Study. Jordan Maddox, AICP, Principal Planner Maddox explained that the Commission would have a joint meeting with the Georgetown Transportation Advisory Board on November 15th to discuss the Williams Drive Corridor Study. He suggested members and public go to transportation.georgetown.org to review the proposals and discussions that are occurring. He stated the final report is due at the end of March. More information to come. K. Discussion and possible action regarding the potential Planning and Zoning meeting schedule for the 2017 calendar year. The calendar for 2017 was presented to the commission. The meetings will still be on the first and third Tuesdays at 6:00 p.m. with the exception of specific holidays. Motion by Fuller, second by Webb to approve the 2017 schedule of meetings. Approved 4 – 0 – 2 (Marler absent and Schroeder recused.) L. Discussion items: • Update on the Unified Development Code Advisory Committee (UDCAC) meetings. (Commissioner Bargainer) No report was given. • Update on the Georgetown Transportation Advisory Board (GTAB) meetings. • Questions or comments from Commissioner-in-Training about the actions and matters considered on this agenda. No questions. • Joint GTAB and P&Z meeting November 15, 2016 • Reminder of the next Planning and Zoning Commission meeting on December 6, 2016 at Council Chambers located at 101 East 7th Street, starting at 6:00 p.m. Motion to Adjourn by Fuller, second by Bargainer at 7:24 p.m. ____________________________________ ____________________________________ Josh Schroeder, Chair P&Z Commissioner Page 7 of 80 City of Georgetown, Texas Planning and Zoning December 6, 2016 SUBJECT: Public Hearing and p o s s ib le ac tion on a Replat of a Final Plat, b eing 5 ac res o f Whitetail S ectio n 2, Lot 37, loc ated at 406 Do e Run. (FP-2016-019) Juan Enriquez, Planner ITEM SUMMARY: Background: This rep lat of a final plat c reates two (2) resid ential lots . Acc es s to the s ite is o ff of Doe Run. No parkland is required as a res ult of this sub d ivision. Public Comments: As req uired by the Unified Develo p ment Co d e, all o wners of p ro p erty within a 200 foot radius of the s ubjec t p ro p erty that are within the original s ubdivis io n were no tified of the rep latting applic ation (10 notices mailed ) and a legal notice advertis ing the p ublic hearing was plac ed in the S un News p aper (Novemb er 20, 2016). Public hearing s igns were not p o s ted o n-s ite s inc e they are not req uired b y the UDC fo r p latting. To date, s taff has not rec eived any written or verbal c o mments in s upp o rt o r agains t the rep latting app lic atio n. Recommended motion: Approve the Replat of Whitetail Sec tion 2, Lo t 37 FINANCIAL IMPACT: None studied at this time. SUBMITTED BY: Juan Enriq uez, Planner and Sofia Nelson, CNU-A, P lanning Directo r ATTACHMENTS: Description Type s taff memo Cover Memo Attachment 1 - Location Map Backup Material Attachment 2 - Whitetail Sec 2, Lot 37 Resubdivis ion Plat Backup Material Page 8 of 80 Georgetown Planning Department Staff Report Whitetail Section 2, Lot 37 Resubdivision Page 1 of 2 Report Date: November 15, 2016 File No: FP-2016-019 Project Planner: Juan Enriquez, Planner Item Details Project Name: Whitetail Sec 2, Lot 37 Resubdivision Project Address: 406 Doe Run Total Acreage: 5 acres Legal Description: Whitetail Section 2, Lot 37 Applicant: Roy Gonzales, Texas Land Surveying, Inc. Property Owner(s): Keith E. Moore & Angelina L. Urista Contact: Roy Gonzales, Texas Land Surveying, Inc. Plat Summary Proposed Lots: Two (2) single-family lots Proposed Streets: None Heritage Trees: None Site Information The property is located within Georgetown’s Extra-Territorial Jurisdiction (ETJ) in a primarily rural single-family neighborhood near the northeast corner of Whitetail Drive and Doe Run, south of Leander Road and east of Interstate 35. The property is flat, primarily undeveloped with an existing single-family residence which will remain. The property has approximately 330 feet of public street frontage along Doe Run. There are no heritage trees on-site. History The property is located within Georgetown’s ETJ and has no zoning regulations. However, the replat of this property is subject to Texas Local Government Code 212 Subchapter A (Regulation of Subdivisions), Unified Development Code (UDC) Sections 3.08 (Subdivision of Land) and 6.01 (Residential Standards) regulations. UDC Section 3.08 states that an application for replatting a property that is or has been subject to single or two family restrictions or zoning within the last 5 years, requires a public hearing and approval by the Planning & Zoning Commission. Therefore, this application is presented at a public hearing for P&Z approval. Utilities Water will be served by an on-site well. Electric service is provided by PEC and sanitary sewer requirements will be handled by On-Site Septic Facilities (OSSF). Page 9 of 80 Planning Department Staff Report Whitetail Sec 2, Lot 37 Resubdivision Page 2 of 2 Transportation The site’s primary inbound and outbound access is on Doe Run through a private driveway. The new lot will also have inbound and outbound access via Doe Run through a new 30 foot private driveway. Trip generation will not be reviewed with the subdivision application since a two lot subdivision will not trigger the need for a Traffic Impact Analysis. Parkland Dedication No parkland is required as a result of this subdivision. There are no parkland fees for less than four residential lots. Staff Analysis The proposed Replat meets all of the requirements of the UDC and is presented for approval. Public Comments As required by the Unified Development Code, all owners of property within a 200 foot radius of the subject property that are within the original subdivision were notified of the replatting application (10 notices mailed) and a legal notice advertising the public hearing was placed in the Sun Newspaper (November 20, 2016). Public hearing signs were not posted on-site since they are not required by the UDC for platting. To date, staff has not received any written or verbal comments in support or against the replatting application. Attachments Attachment 1 – Location Map Attachment 2 – Whitetail Sec 2, Lot 37 Resubdivision Page 10 of 80 Leander Rd §¨¦35 §¨¦35 §¨¦35 L e a n d e r R d Westingho u s e R d (R iver/S t r e a m ) FP-2016-019 Attachment 1 Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only ¯ Location Map 0 0.5 1 1.5Mi LegendSiteParcelsCity LimitsGeorgetown ETJ Page 11 of 80 +(6*+5&1%7/'06&1'5016%106#+06*'4'&56#/2'&5'#.1(6*'70&'45+)0'&5748';14+6+5#070#76*14+<'&+..')#.%12; 6':#5.#0&5748';+0)+0%#557/'501.+#$+.+6;(41/6*'75'1(#0;70#76*14+<'&+..')#.&1%7/'06 Attachment 2 - Whitetail Sec 2 - Lot 37 Resubdivision Page 12 of 80 +(6*+5&1%7/'06&1'5016%106#+06*'4'&56#/2'&5'#.1(6*'70&'45+)0'&5748';14+6+5#070#76*14+<'&+..')#.%12; 6':#5.#0&5748';+0)+0%#557/'501.+#$+.+6;(41/6*'75'1(#0;70#76*14+<'&+..')#.&1%7/'06 Page 13 of 80 City of Georgetown, Texas Planning and Zoning December 6, 2016 SUBJECT: Public Hearing and p o s s ib le ac tion on a reques t to Rezone Lo t 1, Bloc k F, Summit at Rivery Park Phas es 5 & 6, loc ated at 1101 Wo o d lawn Avenue to amend the Summit at R ivery P ark Planned Unit Develo p ment (PUD) Dis trict. (REZ-2016--027, S herato n Geo rgeto wn) Valerie Kreger, AICP, P rinc ip al Planner ITEM SUMMARY: Background: The ap p licant is req ues ting an amendment to the Summit at Rivery Park PUD to alter the signage regulations spec ifically applic able to the mo nument sign fo r the Sheraton at Georgeto wn Ho tel and Conferenc e Center. The current signage s tand ard s within the PUD’s Development Plan allo w fo r s ix frees tand ing mo nument s igns within the o verall S ummit d evelopment with a maximum height of 8 feet eac h and maximum of 48 s q uare feet p er s ign fac e. The p ro p o s ed language would allow one ad d itional mo nument s ign spec ifically o n the hotel s ite with a maximum height o f 12 feet, maximum width of 6 feet, and maximum s ign fac e of 58 square feet (eac h). The req uested amendment d o es no t p ro p o s e any changes to the land us es or other d evelopment s tand ards that would affect any s ep arate agreement assoc iated with the Summit at Rivery P ark d evelopment. This is the fifth amend ment to the Summit at Rivery P ark PUD s inc e its original approval in 2007. Public Comment: To date, s taff has received no written pub lic c o mments , altho ugh staff has received numero us p hone inquiries . Staff Recommendation: Staff rec o mmend s approval of the reques t to amend the Summit at Rivery P ark PUD. FINANCIAL IMPACT: None studied at this time. SUBMITTED BY: Valerie Kreger, AICP, Principal Planner, and S o fia Nels o n, CNU-A, Planning Direc tor ATTACHMENTS: Description Type Staff Report Cover Memo Attachments 1-3 - Location, Future Land Use, and Zoning Maps Backup Material PUD Development Plan Exhibit Page 14 of 80 Georgetown Planning Department Staff Report Summit at Rivery Park PUD, 5th Amendment Page 1 of 5 Report Date: November 30, 2016 File No: REZ-2016-027 Project Planner: Valerie Kreger, AICP, Principal Planner Item Details Project Name: Summit at Rivery Park PUD, 5th Amendment Location: 1101 Woodlawn Ave. Acreage: 4.2 acres Zoning: Planned Unit Development (PUD) Applicant’s Request The applicant is requesting an amendment to the Summit at Rivery Park PUD to alter the signage regulations specifically applicable to the monument sign for the Sheraton at Georgetown Hotel and Conference Center. The current signage standards within the PUD’s Development Plan allow for six freestanding monument signs within the overall Summit development with a maximum height of 8 feet each and maximum of 48 square feet per sign face. The proposed language would allow one additional monument sign specifically on the hotel site with a maximum height of 12 feet, maximum width of 6 feet, and maximum sign face of 58 square feet (each). The requested amendment does not propose any changes to the land uses or other development standards that would affect any separate agreement associated with the Summit at Rivery Park development. This is the fifth amendment to the Summit at Rivery Park PUD since its original approval in 2007. Site Information Physical Characteristics: The 4.2-acre property is located on the east side of Woodlawn Boulevard, just north of IH 35, backing up to Rivery Park. The property is developed with the Sheraton at Georgetown Hotel and Convention Center and parking garage. The property drops in elevation on the east side towards Rivery Park and the North Fork San Gabriel River. Surrounding Properties: The properties adjacent to this site include Rivery Park, the Rivery Park Apartments and two commercial lots – one currently under construction – that are also part of the Summit at Rivery Park PUD. Page 15 of 80 Planning Department Staff Report Summit at Rivery Park PUD, 5th Amendment Page 2 of 5 The surrounding zoning, existing uses and future land uses include: Property History The property was annexed into the City limits in 1986 and was part of the original Rivery Concept Plan and was later included in The Rivery Park Development agreement executed in 2002. In December 2007, the property was rezoned from C-3 to PUD and made part of a Tax Increment Reinvestment Zone (TIRZ). The PUD was amended in September 2010, November 2011, September 2012 and December 2013. Additionally, several agreements were approved in December 2013 including a GEDCO Performance Agreement, a GTEC Performance Agreement, a Tax Increment Financing (TIF) Agreement, a Master Development Agreement, and a Joint Use, Access and Lease Agreement, related to construction and financing of the conference center, parking garage, and public infrastructure needed to support the development. Location Zoning Future Land Use Existing Use North Summit at Rivery Park PUD Regional Commercial Undeveloped (future Brownstones) South Summit at Rivery Park PUD Regional Commercial Rivery Park Apartments East C-3, General Commercial Open Space Rivery Park West Summit at Rivery Park PUD Regional Commercial Developing/ undeveloped commercial lots Page 16 of 80 Planning Department Staff Report Summit at Rivery Park PUD, 5th Amendment Page 3 of 5 2030 Comprehensive Plan The 2030 Plan land use designation is Regional Commercial, which supports uses that draw a regional market, such as major shopping centers, tourist attractions and supporting accommodations that rely on convenient access from major highways. The 2030 Plan Growth Tier Map designation is Tier 1A, which is the portion of the City where infrastructure systems are in place, or can be economically provided, and where the bulk of the City’s growth should be guided over the near term. Zoning District The PUD, Planned Unit Development District, is intended to allow flexibility in planning and designing for unique or environmentally sensitive properties, which are to be developed in accordance with a common development scheme or planned associations of uses. PUD zoning is designed to accommodate various types of development, including a combination or mix of uses. The PUD zoning district may also provide for variations from the standard UDC requirements allowing for creation of a unique product. The C-3 base district is a regional commercial zoning district that is intended for major thoroughfares and intersections. The C-3 District is the most expansive commercial district in the UDC, allowing uses such as retail, office, restaurants, hotels, and apartments, among others. Utilities Electric, water, and wastewater for this development are served by the City of Georgetown. The requested PUD amendment will not result in an increase in the demand for utilities at this site. Transportation Access to the hotel is taken from Woodlawn Avenue, Hintz Road, as well as a public access easement along the property’s southern boundary. A review of traffic impacts was not deemed necessary with this application due to the limited nature of the requested changes to the Summit at Rivery Park PUD. Staff Analysis The Sheraton at Georgetown is a 7-story 221 room hotel with a conference center and parking garage. The UDC’s signage regulations allow for a 6-foot 48 square foot sign, which is appropriate in most situations since the maximum building height of any of the standard zoning districts is 60 feet (generally 5 stories). The adopted Summit at Rivery Park PUD provides for a 2-foot increase in sign height while maintaining the 48 square foot sign face as a standard for all the monument signs throughout the development, regardless of building size. Staff finds that with the increased height and size of the hotel, the increased sign height and size is proportional and appropriate. The proposed PUD revision is limited to signage which does not change the overall scope of the project as currently allowed within the PUD and therefore does not change the development’s conformance with the 2030 Plan and intent of the Future Land Use designation. Additionally, the Page 17 of 80 Planning Department Staff Report Summit at Rivery Park PUD, 5th Amendment Page 4 of 5 revision does not affect any of the agreements between the City and the developer related to development of the hotel, conference center, parking garage, public infrastructure and related uses. UDC Section 3.06.030 establishes the following criteria for zoning changes: The application is complete and the information contained within the application is sufficient and correct enough to allow adequate review and final action This application was reviewed by staff and deemed to be complete. The zoning change is consistent with the Comprehensive Plan The PUD amendment does not change the zoning’s consistency with the 2030 Plan. The zoning change promotes the health, safety or general welfare of the City and the safe orderly, and healthful development of the City The amendment facilitates appropriate development standards for this project and therefore the orderly and healthful development of the City. The zoning change is compatible with the present zoning and conforming uses of nearby property and with the character of the neighborhood The amendment is compatible with the overall vision and character of the Summit at Rivery Park PUD. The property to be rezoned is suitable for uses permitted by the District that would be applied by the proposed amendment. The amendment does not propose to alter any of the uses currently permitted by the PUD. Findings Based on all the information presented, staff has made the following findings: 1. The signage amendment does not change the PUD’s consistency with the 2030 Plan’s Regional Commercial land use category. 2. The increased sign height and size is proportional and appropriate to the 7-story hotel and the development character of the Summit at Rivery Park PUD. 3. The revision does not affect any of the agreements related to development of the hotel, conference center, parking garage, public infrastructure and related uses. Staff Recommendation Staff is recommending approval of the application based on the above findings. Public Comments Public notice was mailed to property owners of 61 properties either within the overall boundaries of the Summit at Rivery PUD or within 200 feet of the property subject to the PUD amendment. Public notice was posted in the Sun newspaper on November 20, 2016, and signs were placed on site. Page 18 of 80 Planning Department Staff Report Summit at Rivery Park PUD, 5th Amendment Page 5 of 5 There have been no written public comments received at the time of this report, although staff has received numerous phone inquiries. Attachments Exhibit 1 – Location Map Exhibit 2 – Future Land Use Map Exhibit 3 – Zoning Map Exhibit A – Development Plan Page 19 of 80 N I H 3 5 R I V E RY B L V D N A U S T I N A V E S IH 3 5 S W I L L I A M S D R Zoning Information REZ-2016-027 Exhibit #3 Coordinate System: Texas State Plane/Central Zone/NAD 83/US Feet Cartographic Data For General Planning Purposes Only Legend Site Parcels City Limits Georgetown ETJ ¯ 0¼½ MiPage 20 of 80 1 PLANNED UNIT DEVELOPMENT FOR THE SUMMIT AT RIVERY PARK Modified August 25, 2016 for Signage Amendment 1. DEFINITIONS 1.1 All definitions referenced in the Unified Development Code of the City of Georgetown, Ordinance No. 2003-15, as subsequently amended and codified in Title 17 of Georgetown Code of Ordinances (the “Code”), shall apply to interpretation of the terms of this Planned Unit Development for the Summit at Rivery Park (this “PUD”). Any terms not defined in this Development Plan shall be construed by applying the Random House Webster’s Unabridged Dictionary, subject to the approval of such interpretation by the director of Planning and Development Services of the City of Georgetown. 2. PROPERTY 2.1 This PUD applies to approximately 31.94 acres of land located within the jurisdictional limits of the City of Georgetown, Texas described by metes and bounds and by plat (for the portions platted) on Exhibit “A” and herein defined as the “Property.” 3. APPROVAL CRITERIA 3.1 This PUD modification has been initiated by the Director pursuant to the Memorandum of Understanding between the City and Novak Brothers LLC and Hines Interests Limited Partnership dated May 14, 2013, as amended, and Section 3.06.020.A.4 of the Code. This PUD is intended to conform to the approval criteria of Sections 3.06.030 and 3.06.040 of the Code. Section 3.06.030 of the Code provides that the following criteria shall be considered by City Council for zoning changes: (a) The application is complete and the information contained within the application is sufficient and correct enough to allow adequate review and final action; (b) The zoning change is consistent with the Comprehensive Plan; (c) The zoning change promotes the health, safety, or general welfare of the City and the safe, orderly, and healthful development of the City; (d) The zoning change is compatible with the present zoning and conforming uses of nearby property and with the character of the neighborhood; and (e) The property to be rezoned is suitable for uses permitted by the District that would be applied by the proposed amendment. Page 21 of 80 2 Section 3.06.040 of the Code provides that, in addition of consideration of the foregoing criteria of Section 3.06.030, the following applicable criteria shall be considered by City Council for approving this PUD: (a) An orderly and creative arrangement of all land uses with respect to each other and to the entire community; (b) A planned and integrated comprehensive transportation system providing for a separation of pedestrian and vehicular traffic, to include facilities such as roadways, bicycle ways and pedestrian walkways; (c) The provisions of cultural or recreational facilities for all segments of the community; (d) The location of general building envelopes to take maximum advantage of the natural and manmade environment; and (e) The staging of development in a manner which can be accommodated by the timely provision of public utilities, facilities and services. 4. DEVELOPMENT ZONES 4.1 General. For the purposes of this PUD, the Property is divided into five (5) Development Zones as shown on Exhibit “B”, being Zone A, Zones B1, B2, and B3, and Zone C. 4.2 Zone A. Zone A consists of approximately 8.190 acres of land described as Block H of Phase 5 of The Summit at Rivery Park Preliminary Plat, shown on Exhibit “B”. Zone A consists of the southern one-third of the land comprising the Property and is the development zone closest in proximity to Interstate 35. Zone A is separated from the remainder of the land comprising the Property by the proposed new Woodlawn and Hershey Avenues. Zone A shall be designed and developed for multifamily residential development. A site plan for the multifamily residential development was submitted on 09/27/2013 (SP-2013-022). 4.3 Zone B1. Zone B1 consists of approximately 4.196 acres of land described as Block F of Phase 5 of The Summit at Rivery Park Preliminary Plat, shown on Exhibit “B”. Zone B1 consists of the rear, central portion of the land comprising the Property and is separated from Zone A by the existing access road and easement to Rivery Park and is generally separated from Zone C by the proposed new Hintz Road. Zone B1 is separated from Zones B2 and B3 by the proposed new Woodlawn Avenue. Zone B1 shall be designed and developed for a hotel with at least 221 rooms, a conference center including a ballroom comprised of at least 16,000 square feet, and a multilevel above- ground public parking garage containing at least 336 parking spaces. A site plan for the Hotel/Conference Center/Parking Garage was submitted on 06/05/2013 (SP-2013-009). 4.4 Zone B2. Zone B2 consists of approximately 2.433 acres of land and is generally depicted as Block E of Phase 5 of The Summit at Rivery Park Preliminary Plat, shown on Exhibit “B.” Zone B2 is separated from Zone B1 by the proposed new Woodlawn Avenue and Zone B3 by the proposed extension of Wolf Ranch Parkway and Page 22 of 80 3 is generally separated from Zone C by the proposed new Hintz Road. Zone B2 shall be designed and developed for mixed commercial use and associated surface parking. 4.5 Zone B3. Zone B3 consists of approximately 3.021 acres of land and is generally depicted as Block G of Phase 5 of The Summit at Rivery Park Preliminary Plat, shown on Exhibit “B.” Zone B3 is generally separated from Zones B1 by the proposed new Woodlawn Avenue and Zone B2 by the proposed extension of Wolf Ranch Parkway and is segmented from Zone A by the proposed new Woodlawn and Hershey Avenues. Zone B3 shall be designed and developed for mixed commercial use and associated surface parking. 4.6 Zone C. Zone C consists of approximately 11.0 acres of land and is generally depicted as Phases 1-4 of the Brownstone at the Summit, and Block A of Phase 5 and Phases 6-12 of The Summit at Rivery Park Preliminary Plat, shown on Exhibit “B”. Zone C represents the northern remainder of land comprising the Property and is generally described as the land north of Hintz Road to the eastern edge of the Property. Zone C shall be designed and developed for Brownstone Single Family Residential Development. 4.7 Site Layout. The Site Layout for the Property is also depicted in Exhibit “B”, attached hereto and incorporated herein by reference for all purposes. 4.8 Final Site Plans. All Final Site Plans must substantially conform to the terms and conditions of this PUD and, in all material respects, with the Site Layout attached hereto as Exhibit “B”. Multiple Final Site Plans may be submitted for each Zone if necessary to accommodate phased development of the Property. A site plan for the Hotel/Conference Center/Parking Garage was submitted on 06/05/2013 (SP-2013-009). A site plan for the Apartments was submitted on 09/27/2013 (SP-2013-022). 4.9 Building Height. As applied herein, “Building Height” shall be defined according to Section 7.03.030(D) of the Code, except that individual residences within the Brownstone residential development, as defined in Section 6 of this PUD, may include rooftop shade structures, provided that such structures shall not occupy more than thirty-three (33) percent of the area of the roof and must not be visible from the public street in front of the residence. Heights of all Buildings to be designed and developed in Zone C shall comply with building height limitations prescribed under Table 7.03.020 for the C-3 zoning designation, except that the individual residences within the Brownstone residential development may exceed the limitations under Table 7.03.020 by five (5) feet. Heights of all Buildings to be designed and developed in Zone A and Zones B1, B2, and B3 may vary from and exceed building height limitations prescribed under Table 7.03.020 of the Code, as follows: (a) The Building Height for any Building in Zone A, save and except those described in Paragraph 5.9(b) below, shall not exceed the greater of eight (8) stories of vertical improvements or one hundred twenty (120) feet. Page 23 of 80 4 (b) The Building Height for any Building situated in any zone designed primarily as a free-standing restaurant will not exceed 45 feet, excluding architectural enhancement subject to City approval. (c) The Building Height for any Building in Zone B1 shall not exceed the greater of fifteen (15) stories or two hundred twenty-five (225) feet. (d) The Building Height for any Building in Zones B2 or B3 shall not exceed the greater of fifteen (15) stories or two hundred twenty-five (225) feet. 4.10 Setbacks. Except for those improvements identified in Section 7 of this PUD (relating to signage), all improvements designed and developed on the Property shall be subject to a 25-foot perimeter setback, provided, however, that no setback requirements shall be applicable to any common lot lines between any of the legal lots comprising the Property, and improvements that encroach on such common lot lines may be designed and developed under this PUD, provided that the same otherwise comply with the requirements of this PUD and the Code. Pursuant to Sections 7.03.030(C)(4) and 16.02 of the Code, landscape features, outside gathering areas, walkways, swimming pools adjacent to Rivery Park, walls, and minor utilities, shall be permitted within required setback areas, provided that the same shall not encroach on a public utility easement without a License to Encroach. To the extent defined under the Code, the improvements consisting of these features will be included in impervious cover calculations. 4.11 Impervious Cover. Impervious cover shall not exceed seventy-five (75) percent as applied to the aggregate sum of the building and improvement footprints compared to the comprehensive area of land comprising the Property. Individual site plans for the Property shall tabulate cumulative totals relative to impervious cover for the Property. In no case shall a site plan be approved if it causes the impervious cover on the comprehensive area of land comprising the Property to exceed seventy-five (75) percent. 5. APPLICABILITY OF CITY ORDINANCES 5.1 This PUD addresses certain zoning requirements applicable to all portions of the Property. All design, development, and use criteria not specifically covered by this PUD shall be subject to the applicable provisions of the Code. All design, development and use of the Property shall conform to the PUD described herein and, unless superseded, amended or controverted by the terms of this PUD, to a General Commercial District (C-3), which is the zoning designation most similar to and compatible with the design, development and use proposed for the Property. 5.2 The following uses shall be the only allowed uses of the Property: (a) Zone A – Multi-family residential development; (b) Zone B1 – Hotels and Conference/Event Centers, if in conformance with all applicable provisions of this PUD and all written agreements between the City and the owner of the Property in the PUD pertaining to same; (c) Zones B2 and B3 –Limited Service Hotel and/or residential uses, if located on the second floor or above (prohibited on the ground floor); Page 24 of 80 5 (d) Zone C – Brownstone Residential Development, if in conformance with Section 6 of this PUD; (e) Notwithstanding the foregoing, in addition to the uses set forth and permitted in (a)-(d) above, any Zone can include the following allowable uses– (1) Restaurant (no drive-thru); (2) Bar, tavern or pub; (3) General office (upper-story only); (4) General retail; (5) Personal services; and (6) Parking garages. All other uses are prohibited. In addition, tax-exempt uses are prohibited in every Zone on the Property. 6. BROWNSTONE SINGLE FAMILY RESIDENTIAL 6.1 General. Zone C may be developed with Brownstone single family dwellings. The Brownstones are single family dwellings with shared walls on one or more sides situated on separate, legally platted lots. Home-based businesses as an accessory use as defined in Section 5.02.020.E of the Code are permitted in Brownstones. 6.2 Dwelling Size and Number, Setbacks, Lot Dimensions. Brownstones are zero lot line single family dwellings with no required front, rear or side setbacks. Brownstones Maximum Number of Dwellings Connected on One or More Sides, constituting a block of individually platted homes 6 Lot & Dwelling Width, minimum 18 feet Lot & Dwelling Depth, minimum 40 feet Height, maximum 50 feet Dwelling Size, minimum 1700 square feet 6.3 Design Standards. Brownstones shall contain variation through articulation of front façades, using different building materials, colors, entries and window design. Garages for two vehicles per dwelling will be accessed from Brownstone Alleys or Brownstone Streets. Rooftop outdoor living areas are expressly permitted. A schematic presentation of Brownstone lots and design is shown in Exhibit “D”. 6.4 Site Plans. Individual Site Plans for the brownstone lots within Zone C shall not require Site Plan review and shall be reviewed following the Building Permit review process for single-family residential properties, provided that the buildings conform to the building configurations approved in administrative exception AE-2011-007 on file at the Georgetown Planning Department, and provided that a Site Plan will be required and Page 25 of 80 6 reviewed for all other properties and open space lots within Zone C. The site plan approval for an open space lot shall be required prior to the approval of the building plan for the adjacent brownstone lot. Any final Site Plan must also conform in all material respects to the Site Layout, all applicable Exhibits, and this PUD document. 7. MASTER SIGN PLAN 7.1 A comprehensive signage plan for the development of the Property (the “Master Sign Plan”) shall be required. The Master Sign Plan serves to implement signs uniformly as a means of clear visual communication, and is intended to cause the designs of any signs on the Property to be complementary to the natural environment, and to improve pedestrian and vehicular safety. Signs may only convey the name of the businesses and the products or services offered within the Property, provided, however, that temporary construction signs, signs advertising portions of the Property for sale or lease, and temporary signs announcing special events on any portion of the Property shall be permitted. Monument signs, walls, fencing, architectural features, as well as sign design and lettering, along the public right-of-way adjoining the Property will be homogenous and will consist of a standard design to ensure that the comprehensive signage for the Property does not dominate the streetscape. All signs shall be constructed of materials and colors compatible with those utilized on the Buildings’ facades so as to blend into the environment and the development scheme of the Property in general. Billboard signs shall not be erected on the Property. 7.2 The Master Sign Plan shall be submitted to the City for approval by the Building Official prior to and as a condition for final approval of any site plan for any part of the Property. Signage designed, developed or constructed within the Property shall comply with the approved Master Sign Plan. 7.3 Up to six (6) Monument Signs may be designed, developed and constructed along the public right-of-way of the Property, and may be located along the Property’s boundaries in direct proximity of the planned entrances to the Property. Monument Signs shall not be subject to a 25-foot setback from the public right-of way, shall be limited to eight (8) feet in Building Height with a maximum of forty-eight (48) square feet for each of the two (2) permitted sign faces per Monument Sign, and will be installed in such areas as to maximize the public safety of owners, tenants, and invitees of and to the Property, and to enhance the efficiency of vehicular and pedestrian traffic to and from the Property. Monument Signs shall comply with minimum setbacks prescribed in Table 10.06.010 of the Code. 7.4 Low-Profile Signs may be used in lieu of Monument Signs. Low-Profile Signs must not exceed ten (10) feet in Building Height and are otherwise subject to the same limitations applicable to Monument Signs. Low-Profile Signs shall not be subject to a 25- foot setback from the public right-of way. Low-Profile Signs shall comply with minimum setbacks prescribed in Table 10.06.010 of the Code. Page 26 of 80 7 7.5 As the Property represents an integrated and comprehensive mixed use development which is distinct from adjoining developments, architectural features, walls or fencing, not to exceed ten (10) feet in height, may be used at one or more entries fronting Rivery Boulevard to delineate the development and to display the development name and logo. The name of the development and its logo may be used on entry improvements in lieu of Monument Signs, providing that individual business names or logos shall not allowed on any entrance improvements. The maximum area of lettering attached to the architectural features, walls or fencing shall not exceed 48 square feet on each side of the entry. In order to tie the Property together, similar architectural features, walls or fencing may be used along Rivery Boulevard, providing such features do not obstruct vehicular view corridors and do not exceed height requirements prescribed in Section 7.05.010 of the Code. The variance between the maximum heights allowed for entry improvements and the architectural features, walls or fencing along Rivery Boulevard may be achieved by graduating the height between the two maximum heights. The development logo, without the development name, may be used on architectural features, walls or fencing along Rivery Boulevard as a design feature and not be considered signage. Architectural features, walls or fencing, and the attached signage at entries, shall not be subject to a 25-foot setback from the public right-of way and shall be included in the Master Sign Plan. 7.6 Internal Directional Signs and Wayfinding Signs of similar design and colors are allowed throughout the Property and shall be permitted in addition to the Property’s signs along the public right-of-way. Directional Signs shall conform to the specifications set forth in Section 10.03.020 of the Code. Wayfinding Signs which are of a style and size as Municipal Wayfinding Signs may include the names of businesses located on the Property. The number of Internal Directional and Wayfinding Signs will not exceed what is sufficient to provide safe and efficient use of the Property. Directional, wayfinding, and information signage for the public parking garage located in Zone B1 shall be as required by the City in its sole discretion. 7.7 In general, Electronic Message Centers and unshielded Neon Signs shall not be permitted to be designed, developed or constructed on the Property; provided, however, that a maximum of three (3) Electronic Message Centers may be allowed in outdoor public areas internal to the Property provided that the same are not visible from the public right-of-way on Rivery Boulevard and the same otherwise do not impair the safety or wellbeing of the public or any owner, tenant, or invitee of any portion of the Property; and provided further that encased Neon Signs shall be permitted on restaurant building facades provided the same are situated at least one hundred feet (100’) from the public right-of-way on Rivery Boulevard. Electronic Message Centers will be situated so as not to be disruptive to internal vehicular traffic and will principally be used to inform visitors to the Property of activities, events or festivals planned or occurring throughout the community. 7.8 The Hotel, Conference Center, public Parking Garage and Buildings in Zones A, B1, B2, and B3 may be accessed by several proposed driveways from Rivery Boulevard and pedestrian access ways from Rivery Park. Wall signs based upon each Page 27 of 80 8 Building’s primary entrance and Building Façade as defined by Section 16.02 shall be expressly permitted under this PUD pursuant to Section 10.06.030(C) of the Code. Under this PUD, one wall sign secured to the top level of each of the respective Buildings which can be viewed from each view corridor is expressly permitted for the proposed hotel, conference center, and Buildings in Zones A, B1, B2, and B3. The proposed hotel is subject to three (3) view corridors, and therefore a maximum of three (3) wall signs shall be permitted on these improvements. The Buildings situated near the Property’s southerly and easterly boundary lines are subject to two (2) view corridors, and therefore a maximum of two (2) wall signs shall be permitted on these improvements. Wall signs will also be allowed on the parking garages in Zones A, B1, B2, and B3. Specifications for these signs will not exceed those outlined in Section 10.06.030(C)(1) and Table 10.06.010 of the Code, and shall otherwise remain subject to the specifications set forth in the finally approved Master Sign Plan. 7.9 In addition to the six (6) Monument Signs allowed in Section 7.3 along the Property’s boundaries and at the entrances to the Property from the Rivery Boulevard, one (1) additional Monument Sign shall be allowed in front of the Hotel and Conference Center to enhance the efficiency of the vehicular and pedestrian traffic as they approach the main entrance to the Hotel and Conference Center. This one Monument Sign shall be located in the landscaped island located in front of the Hotel and public Parking Garage. The sign shall be limited to twelve feet (12’-0”) in height and six feet (6’-0”) in width with a maximum sign area of 58 square feet for each of the two (2) permitted sign faces. 8. STORM WATER DRAINAGE MAP, WATER QUALITY, AND GREY WATER 8.1 Storm Water Detention. The natural flow of storm water drains across the Property from the south and southwest to the North Fork of the San Gabriel River or to natural drainage channels that discharge to said river. Detention structures are typically required to mitigate the increase in storm water runoff associated with any increase in impervious cover resulting from development; however, due the Property’s location adjacent to the San Gabriel River, detention structures are not required as any increase in runoff will not impact any property or structures downstream of the Property. A comparison of the developed runoff hydrograph of the Property to the pre-development hydrograph of the Property and to the river hydrograph must show that the development of the Property, in accordance with this PUD and the Code, will not impact structures and properties adjacent to the Property or properties downstream of the river. Storm water runoff from the developed area of Zones B1, B2, B3, and C will discharge from the site via overland and/or conveyance through the existing natural channels. The existing natural channels are primarily rock lined with sporadic natural shrubbery. Necessary drainage measures will be implemented to minimize degradation to the vegetation within the natural channels caused by any increased runoff during normal rainfall events. These measures may include providing detention to mitigate increases in runoff for the one-year and two-year occurrence intervals. Page 28 of 80 9 Two existing storm sewer lines traverse the Property from Rivery Boulevard to natural drainage channels that convey storm water to the existing water quality pond. These storm sewer lines were constructed as part of The Rivery Phase One Construction Plans by Urban Design Group as approved on June 4, 2002. The construction plans for the existing storm sewer lines do not indicate any storm sewer inlets to serve the Property. Additional engineering calculations shall be required as part of any site plan review process to determine if adequate capacity exists in the storm sewer lines to serve the Property. The existing topography appears to allow for direct discharge into the adjacent natural drainage channels that lead to the existing water quality pond. 8.2 Water Quality. The Property is located within the Edwards Aquifer Recharge Zone according to the TCEQ USGS Quad Map. The Property must comply with the requirements of Chapter 11 of the Code and the Edwards Aquifer Rules of the Texas Commission on Environmental Quality (TCEQ). Zone A and the eastern 4.29 acres of the combined Zones B1, B2, and B3 contribute to the existing adjacent water quality pond maintained by the City. The existing wet pond is approved and regulated by TCEQ Edwards Aquifer Rules. All areas contributing to the existing water quality pond shall comply with the approved Water Pollution Abatement Plan (WPAP) as amended. However, the pond can be modified to serve a more intense development and/or capture additional areas of the Property, provided that any expansion is approved by the City’s Parks & Recreation Director and meets TCEQ Edwards Aquifer Rules. Pond modifications cannot diminish access to Rivery Park amenities, and existing amenities must be restored or improved following pond modifications.   The remaining tracts of land in Zones B1, B2, B3, and C will require water quality controls in accordance with the TCEQ Edwards Aquifer Rules. The water quality controls may be accomplished by: (a) Natural vegetative filter strips or one (1) additional wet water quality pond located within the City’s property known as Rivery Park – In order for natural vegetative filter strips or one (1) additional wet water quality pond to be viable and approved by the City, plans and analysis will have to be completed to ensure that utilizing the existing park area will: (i) not cause additional erosion within Rivery Park; (ii) not adversely impact the existing natural vegetation (grasses, brush, or trees) within Rivery Park; (iii) meet the minimum requirements established by TCEQ for vegetative filter strips. (b) Sedimentation/filtration or other TCEQ approved controls or by natural vegetative filter strip located within the City’s adjacent water quality pond located adjacent to the Rivery Boulevard Bridge – The existing water quality pond will have to be enlarged to accommodate any additional contributing area in accordance with the requirements of TCEQ and the City engineer. In order for this option to be viable and approved by the City, plans and analysis will have to be completed to ensure that utilizing Page 29 of 80 10 the City’s existing water quality pond along Rivery Boulevard will: (i) not cause additional erosion within Rivery Park; (ii) not adversely impact the existing natural vegetation (grasses, brush, or trees) within Rivery Park; and (iii) meet the minimum requirements established by TCEQ. (c) On-site water quality controls meeting the minimum requirements established by the TCEQ Edwards Aquifer rules – In order for this option to be viable and approved by the City, plans and analysis will have to be completed to ensure that utilizing on-site water quality controls will: (i) not cause additional erosion within Rivery Park; (ii) not adversely impact the existing natural vegetation (grasses, brush, or trees) within Rivery Park; and (iii) meet the minimum requirements established by TCEQ for vegetative filter strips. (d) A combination of two or more of the items above may be utilized to accomplish the required water quality requirements. All water quality control methods, location, and scale are subject to approval by the City by and through its City Engineer. 8.3 Grey Water Line. In the event that any owner of the Property intends to use or access the City’s grey water line in the future, an agreement between the developer and the City of Georgetown regarding access, use and easements will be necessary to enable the developer to access the City’s grey water line, which runs along the bank of the North Fork of the San Gabriel River and which is located in the City’s property known as Rivery Park, for the purposes of irrigation in Rivery Park and on the Property and for other uses as available, permitted, and agreed to by the City of Georgetown. In the event that connection occurs, connection to the City’s grey water line will be positioned along the Property’s most northern boundary so as to be least disruption to parkland on the east, unless otherwise approved by the Development Engineer. 9. ENVIRONMENTAL PROTECTION 9.1 Development on the Property shall comply with all environmental protection standards detailed in Chapter 11 of the Code, except as otherwise specified in this PUD. 10. ROADWAY INFRASTRUCTURE 10.1 The Property has approximately 2,020 feet of frontage along Rivery Boulevard, a divided arterial roadway. Rivery Boulevard has five (5) existing median cuts adjacent to the Property. Existing median cuts are as follows: (a) At the southwestern most corner of the Property, with an accompanying curb cut and public access road to Lot 1-1, Block A, of the Replat of Rivery Park, Lot 1, Block A, and Lot 1-2, Block A, of the Replat of Rivery Park, Lots 1-2 and 1-3, Block A; (b) At the southwest corner of Lot 1, Block A, of Rivery Park II subdivision, with no accompanying curb cut; Page 30 of 80 11 (c) At the proposed new Hershey Avenue as depicted on The Summit at Rivery Park Preliminary Plat, also being the existing curb cut and public access road to Rivery Park; (d) At the proposed extension of Wolf Ranch Parkway as depicted on The Summit at Rivery Park Preliminary Plat; and (e) At the proposed new Hintz Road as depicted on The Summit at Rivery Park Preliminary Plat. 10.2 The City of Georgetown transportation criteria require that a driveway on a divided arterial be separated by a minimum of 305 feet based upon the posted speed limit of 40 miles per hour, unless a waiver is approved by the City Engineer. No additional median cuts or alterations are proposed for this PUD. Curb cuts with internal driveways to access the Property will be utilized at each of the existing median cuts. Subject to a field study according to Section 3 of Chapter 2 of the TxDOT Design Manual showing stopping sight distances and attached as Exhibit “E”. 10.3 A Traffic Impact Analysis dated November 5, 2013 has been performed for this PUD. The Traffic Impact Analysis was not required by the existing PUD as amended and restated hereby. Nothing in this PUD shall require the owner of the Property to implement the Traffic Impact Analysis prior to development of the Property. 10.4 Driveway widths at all entries to the Property shall comply with Section 12.04 of the Code. 11. INTERNAL PEDESTRIAN & VEHICULAR CIRCULATION 11.1 The improvements within this PUD will be designed to maximize pedestrian and vehicular circulation within the Property, and all of the existing median and curb cuts will be integrated therein for ingress and egress from and to the Property. Construction of (i) two (2) additional curb cuts at existing median cuts along Rivery Boulevard in accordance with the Code; and (ii) one (1) additional curb cut without a corresponding median cut shall be permitted under this PUD to provide ingress and egress to and from the Property. The location of the additional curb cut described in (ii) above shall be subject to a field study according to Section 3 of Chapter 2 of the TxDOT Design and to approval by the City Engineer. This PUD will include pedestrian and vehicular circulation plans designed to provide access to all areas within Zone A, Zones B1, B2, and B3, and Zone C, and will incorporate homogenous design features for all Buildings and other improvements and appurtenances within the Property, and to provide reciprocal access between the Property and the City’s contiguous property known as Rivery Park. All designs for internal pedestrian and vehicular circulation shall comply with the Americans With Disabilities Act, as amended, and the Texas Accessibility Standards as codified in the Texas Architectural Barriers Act, Article 9102, Texas Revised Civil Statutes, as amended. Page 31 of 80 12 11.2 After final approval of this PUD, the general alignment of proposed internal pedestrian and vehicular circulation may be modified from that shown in Exhibit “B” to accommodate Building locations on the approved site plan(s) and for the protection of trees and fire safety requirements. It is the intent of this PUD that vehicular streets internal to the Property be considered as public streets. Design Details for public streets on the Property are depicted in Exhibit “C”, which is attached hereto and incorporated herein as part of this PUD. Public streets within the Property shall be designated as Mixed Use Streets, Brownstone Streets, and Brownstone Alleys. 11.3 The horizontal and vertical curves in the Brownstone Streets and the Brownstone Alleys in Zone C shall be designed and posted for 20 miles per hour. 11.4 Utility depth in the Brownstone Streets cannot exceed ten (10) feet. Street trees will be planted in a manner which prevents root growth from interfering with underground utilities, sidewalks and curbs or other public infrastructure. Locations for street trees and utilities will be specified in plats and construction plans. 11.5 The Brownstone Alleys shall be maintained at no cost to the City. 11.6 Fire-rated vehicular access will be provided on at least two sides of the multi- story hotel(s). Alternate materials, such as grasscrete, may be used to provide access. 11.7 Individual site plans may utilize traffic calming methods in all Zones of the Property to slow traffic and to ensure pedestrian safety. 11.8 Planned pedestrian walkways on the Property will feature outdoor amenity areas and will be designed to connect to amenities located in the City’s property known as Rivery Park. Pedestrian access between Rivery Park and the Property is planned via at least two outdoor amenity areas. Pedestrian access must also be provided from Rivery Park to the public parking garage. 11.9 Vehicular access between the Property and Rivery Park will be maintained at all times via a roadway which will connect to a parking area in Rivery Park. The park access road may be relocated to the south side of the Property, providing that any relocation include a parking area with the same or an additional number of parking spaces as the existing parking area in Rivery Park. The park access road will be well marked for the public and noted by signage located on the Property’s perimeter and adjacent to Rivery Boulevard. 12. PARKING REQUIREMENTS 12.1 In Zone A, the parking shall comply with off-street parking and guest parking requirements for household living as prescribed in Table 9.02.030(A) of the Code. Parking requirements may be reduced if a Parking Study justifying the reduction is submitted with the Site Plan and approved by City Council. Page 32 of 80 13 12.2 A Rivery Hotel and Conference Center Parking Analysis was presented to the City Council on August 13, 2013 (the “Parking Analysis”) for Zone B; therefore, the following parking requirements shall apply in Zone B: Zone B1: Pursuant to the Rivery Hotel and Conference Center Parking Analysis presented to the City Council on August 13, 2013 (the “Parking Analysis”), a minimum of 336 parking spaces must be provided in a multilevel above-ground public Parking Garage located in Zone B1. An additional 27 parking spaces must also be provided to serve the uses in Zone B1, but may be provided as surface parking spaces in Zones B1, B2 or B3. Any additional off-site parking (over and above the minimum number of on-site parking spaces required in Zone B1), must comply with Section 9.02.050(B) of the Code. Zones B2 and B3: At least 445 parking spaces, plus any portion of the 27 surface parking spaces that are not located in Zone B1, must be in Zones B2 and B3. These spaces can be surface parking lot spaces or spaces in a parking garage; provided however, that the public Parking Garage servicing Zone B1 cannot be used to satisfy the requirement to provide parking spaces in Zones B2 and B3. Parking requirements may be reduced within Zones B2 and B3 by up to twenty percent (20%), if an updated Parking Analysis justifying the reduction is presented to and approved by City Council. 12.3 In Zone C, the Brownstone residential development, as defined in Section 6 of this PUD, parking shall comply with off-street parking and guest parking requirements for household living as prescribed in Table 9.02.030(A) of the Code. 12.4 Parking space dimensions for off-street parking in all Zones shall meet dimensions prescribed in Section 9.03.020 of the Code, except that drive aisle widths within a multi-level parking structure may be reduced to 24-feet. 13. LANDSCAPING, PRIVATE OPEN SPACE, COMMON RECREATION AREA & OUTDOOR AMENITY AREAS 13.1 Landscape Areas. Landscape requirements for this PUD shall meet all applicable requirements in Chapter 8 of the Code, unless otherwise stated. Bufferyards do not apply to this Property pursuant to Section 8.04.060 of the Code. The non-residential landscaping requirements of Chapter 8 of the UDC shall be applied to the Property. Individual site plans for the Property shall tabulate cumulative totals relative to landscaping for the Property. Street landscaping on the public streets within the Property shall fall under the landscape requirements for A and B Streets and for Alleys under the Zoning Regulations for Mixed Use Zoning Districts in order to accommodate the intended density of this PUD’s mixed use development. Page 33 of 80 14 13.2 Landscaping for individual brownstone lots shall be addressed on the site plan surrounding the lot and shall not be required on the individual lot. 13.3 Maintenance. The outdoor amenity areas, private open space, common recreation areas, sidewalks, trees, landscaping and irrigation in the rights of way and on the Property must be maintained at no cost to the City. 13.4 Private Open Space. For brownstone lots in Zone C, Private Open Space requirements outlined in Section 6.03.070(C)(3) of the Code shall be met by private rooftop decks on each unit. 13.5 Common Recreation Area. For brownstone development in Zone C, Common Recreation Area requirements outlined in Section 6.06.020 of the Code shall be met by a series of pocket parks internal to Zone C. Pocket parks will include trails and landscaped sitting areas and may include picnic areas or game court areas. In total, these pocket parks and Amenity Area “1” as detailed in Section 13.6(a) of this PUD shall satisfy requirements for Common Recreation Area in Zone C by meeting the combined total for square feet required per dwelling. These areas shall be reviewed and constructed in conjunction with the adjacent site plan. Common Recreation Area for any stand-alone multifamily development shall be addressed with the site plan review for that development. 13.6 Amenity Areas. The amenity areas within the Property shall be designed so as to complement and not conflict with the natural environment of the Property. The Property shall contain at least three (3) Amenity Areas. Each of these areas will incorporate a theme of natural elements and architecture to support this purpose. Amenity Areas “3” and “4” shall satisfy all requirements for Public Open Space and Common Recreation Area in Zone A and Zones B1, B2, and B3. Suggested Amenity Areas are depicted in Exhibit “B” as follows: (a) Amenity Area “1” – The Central Green, located in Zone C: This area will comprise a large, grassy open area between Buildings. Any improvements in this area will be constructed with materials and finishes that are compatible with those on adjacent Buildings within the Property. The design of this area may encompass gathering and sitting areas which will be visually attractive from within the Buildings adjacent to this area. This area may incorporate water feature(s) that complement an urban plaza and which may be artful in nature. (b) Amenity Area “3” – The Overlook Sector, located along the eastern perimeter of Zone A and Zone B1 of the Property: The Overlook Sector will serve as an extension of the outdoors to adjacent Buildings within the Property and designs for this area may include seating and viewing areas to serve pedestrians on the walkways that encircle the development areas of the Property. The design for this area will also comprise one of two major pedestrian walkways between the Property and Rivery Park. Hardscape Page 34 of 80 15 elements will be constructed with materials and finishes that complement the adjacent Buildings within the Property. The design of this area may include gathering and sitting areas along the eastern perimeter of the Property, and may include connectivity and access to other Amenity Areas. (c) Amenity Area “4” – The Pedestrian Plaza Sector, located on both sides of the vehicular street running in front of the hotel and conference center and connecting the Buildings in Zone A and Zones B1, B2, and B3 with the Central Green in Zone C: This area will serve as arrival areas and connections to and between the Buildings. This area shall be designed to provide for efficient pedestrian movement between all areas of the Property and may include viewing areas and corridors. Hardscape elements will be constructed with materials and finishes that complement the adjacent Buildings within the Property. The design of this area may include gathering and sitting areas, and may include connectivity and access to Amenity Area “1”. The design for this area shall also preserve the existing 37-inch caliper Live Oak creating a large shady plaza for outdoor seating. The seating area will provide a gathering spot overlooking Rivery Park and the North Fork of the San Gabriel River below. This area may incorporate water feature(s) that complement an urban plaza and which may be artful in nature. 13.7 Parkland Dedication. Fees will be paid in lieu of parkland dedication in an amount equal to $250 per new dwelling unit, except that, for each structure containing more than four (4) dwelling units, the fee shall be $200 per dwelling unit. For the purposes of this PUD and the calculation of fees, individually platted Brownstone dwellings in Zone C are considered individual dwelling units and parkland dedication fees shall be paid prior to final plat recordation. 13.8 Size and Design Approval. Specific size and design of pocket parks and amenity areas may vary from depictions in Exhibit “B”, but will be approved by the City as part of the individual site plans of any adjacent property. 13.9 Rivery Park Enhancements. Scope and design of enhancements to Rivery Park are as stated in the Parkland Improvements Agreement dated June 26, 2013 by and between the City and Brae Group, Ltd., and the Project Plan and Financing Plan for the Rivery Park Tax Increment Reinvestment Zone, as amended. 14. TREE PRESERVATION 14.1 A Tree Preservation Plan for the entire development, including mitigation, shall be submitted to and approved by the City Council prior to the approval of any additional Site Plan. 15. BUILDING DESIGN & MATERIALS Page 35 of 80 16 15.1 With the exception of the Brownstone residential development in Zone C, as defined in Section 6 of this PUD, all Buildings designed for and constructed on the Property will comply with the Non-Residential Design Standards set forth in Section 7.04 of the Code unless otherwise provided for in this PUD. Any stand-alone multifamily constructed in Zone A shall also meet any applicable requirements of Chapter 6 of the UDC in addition to the applicable regulations of Chapter 7. 16. EXTERIOR LIGHTING 16.1 Exterior Lighting on the Property and its Buildings will comply with the requirements set forth in Section 7.05 of the Code related to outdoor lighting unless otherwise described in this PUD. 17. PUD MODIFICATIONS 17.1 This PUD represents the allowable uses and design standards for the five Zones contained within the Property. Notwithstanding anything to the contrary in the Code, modifications to any provision of this PUD, the Site Layout, or Final Site Plan for the Hotel, Conference Center, or public Parking Garage, must be approved by City Council. 18. LIST OF EXHIBITS 18.1 The following exhibits are attached hereto and incorporated herein by reference: (NOTE: Letter sized copies of each oversized exhibit must also be submitted.) A. Legal description of the Property. B. Site Layout, showing Zone boundaries, Park access, amenity areas and general pedestrian and vehicular circulation. C. Schematic Presentation of Street Design Details. D. Schematic Presentation of Brownstone lots and design. E. Field Study Showing Stopping Sight Distances. Page 36 of 80 17 EXHIBIT A – THE PROPERTY The Final Plat of BROWNSTONE AT THE SUMMIT PHASE 1, as recorded in Document Number 2011047662 of the Official Public Records of Williamson County, Texas, also being a replat of 0.604 acres previously described as part of Lot 4, Block “A”, THE RIVERY PARK II, a subdivision in Williamson County, Texas, according to the map or plat thereof recorded in Cabinet AA, Slides 20-23, Plat Records of Williamson County, Texas; The Final Plat of BROWNSTONE AT THE SUMMIT PHASES 2 – 4, as recorded in Document Number 2013070833 of the Official Public Records of Williamson County, Texas, also being a replat of 1.023 acres previously described as part of Lot 4, Block “A”, THE RIVERY PARK II, a subdivision in Williamson County, Texas, according to the map or plat thereof recorded in Cabinet AA, Slides 20-23, Plat Records of Williamson County, Texas; and The Final Plat of THE SUMMIT AT RIVERY PARK PHASES 5 – 6, as recorded in Document Number 2013116146 of the Official Public Records of Williamson County, Texas, also being a replat of 24.07 acres previously described as part of Lot 4, Block “A”, and Lots 1, 2, 3, 5, 6, and 7, Block “A”, THE RIVERY PARK II, a subdivision in Williamson County, Texas, according to the map or plat thereof recorded in Cabinet AA, Slides 20-23, Plat Records of Williamson County, Texas, Lot 2, Block “A”, RIVERY PARK, a subdivision in Williamson County, Texas according to the map or plat thereof recorded in Cabinet W, Pages 212-214 of the Plat Records of Williamson County, Texas. The remaining portion, not otherwise described above, of The Summit at Rivery Park Preliminary Plat approved by the City’s Planning & Zoning Commission on October 31, 2012, being an unrecorded plat further described as: A portion of Lot 4, Block “A”, and Lots 1, 2, 3, 5, 6, and 7, Block “A”, THE RIVERY PARK II, a subdivision in Williamson County, Texas, according to the map or plat thereof recorded in Cabinet AA, Slides 20-23, Plat Records of Williamson County, Texas; and Lot 2, Block “A”, RIVERY PARK, a subdivision in Williamson County, Texas according to the map or plat thereof recorded in Cabinet W, Pages 212-214 of the Plat Records of Williamson County, Texas. Page 37 of 80 Page 38 of 80 C Page 39 of 80 D Page 40 of 80 E Page 41 of 80 City of Georgetown, Texas Planning and Zoning December 6, 2016 SUBJECT: Public Hearing and p o s s ib le ac tion on a reques t to Rezone approximately 78.29 acres in the Addison Survey, loc ated near the inters ectio n o f Inner Lo o p and Eas t University Avenue. (R EZ-2013-016, Geo rgeto wn 120 Holdings) Jordan Maddox, AIC P, P rinc ip al P lanner ITEM SUMMARY: Zoning Pro pos al Summary The s ubjec t property is loc ated in the eastern quad rant of the c ity, near the inters ec tion of Inner Lo o p and East Univers ity Ave. T he p ro p erty was zoned C-3 with c o nditio ns in 2007 and the proposed PUD retains s o me of the o riginal c o nditio ns while providing fo r a greater mix of uses and dens ities . S ingle-family and multi-family are p ro p o s ed to be ad d ed to the c o mmercial/retail entitlements, with a flexib ility to mix produc t typ es and sizes . T he ap p licant and s taff have worked to ens ure that the City c an purs ue a fire s tatio n o n the s ite as well as an innovative arrangement fo r p ublic parkland. Pub lic Notice Pub lic Notice was provid ed by newspaper, letters , and signs o n the property in ac cordance with State Law and the Unified Development Code Pub lic Comments No o fficial co mments have b een received as of the writing o f this rep o rt Staff Recommendatio n Staff is recommending ap p ro val o f the p ro pos ed PUD Rec o mmended Motio n Rec o mmend to the City Counc il approval of the proposed PUD rezo ning. FINANCIAL IMPACT: . SUBMITTED BY: Jordan Maddo x, AIC P, P rinc ip al P lanner ATTACHMENTS: Description Type Location Map Backup Material Propos ed PUD Development Plan Exhibit Propos ed PUD Exhibits Exhibit Background Exhibits Backup Material Staff Report Backup Material Page 42 of 80 W University Ave E U n i v e r s i t y A v e NAustinAve Southw este r n B l v d E U n i v e r s it y A v e NE Inner Loop SE Inner Loop NColleg e St N Au s t in Av e ¬«130 S Austi n Ave ")971 EMorro w St N orth w estBlvd REZ-2013-016Exhibit #1 Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only ¯ Location Map 0 0.5 1Mi Le ge ndSiteParcelsCity LimitsGeorgetown ETJ Page 43 of 80 EXHIBIT A GTOWN 120 HOLDINGS Planned Unit Development Development Plan A. PROPERTY The GTOWN 120 HOLDINGS Planned Unit Development District is located within the jurisdictional limits of the City of Georgetown, Texas, which land consists of four (4) lots and encompasses approximately 78.2899 acres, OUT OF THE ADDISON, WM. SURVEY, WILLIAMSON COUNTY, TEXAS, which are collectively herein defined as the “Property”, and which are legally described as follows: GTOWN 120 HOLDINGS LP, et al. AW0021 AW0021 - Addison, Wm. Sur., ACRES 76.2491 DOC. #2013014417 | O.P.R.W.C. | 76.249 acres GTOWN 120 HOLDINGS LP, et al. AW0021 AW0021 - Addison, Wm. Sur., ACRES 0.66 DOC. #2013014417 | O.P.R.W.C. | 0.66 acres GTOWN 120 HOLDINGS LP, et al. AW0021 - Addison, Wm. Sur., ACRES 1.2909, (ROW EASEMENT) DOC. # 2013014417 | O.R.W.C. | 1.2909 acres GTOWN 120 HOLDINGS LP, et al. AW0021 - Addison, Wm. Sur., ACRES 0.09, (ROW EASEMENT) DOC. #2013014417 | O.R.W.C. | 0.09 acres B. PURPOSE This PUD is intended to conform to the approval criteria of Sections 3.06.030 and 3.06.040 of the Code. Section 3.06.030 of the Code provides that the following criteria shall be considered by City Council for zoning changes: 1. The application is complete and the information contained within the applica tion is sufficient and correct enough to allow adequate review and final action; 2. The zoning change is consistent with the Comprehensive Plan; 3. The zoning change promotes the health, safety, or general welfare of the City and the safe, orderly, and healthful development of the City; 4. The zoning change is compatible with the present zoning and conforming uses of nearby property and with the character of the neighborhood; and 5. The property to be rezoned is suitable for uses permitted by the District that would be applied by the proposed amendment. Page 44 of 80 Section 3.06.040 of the Code provides that, in addition of consideration of the foregoing criteria of Section 3.06.030, the following applicable criteria shall be considered by City Council for approving this PUD: 1. A variety of housing types, employment opportunities, or commercial services to achieve a balanced community; 2. An orderly and creative arrangement of all land uses with respect to each other and to the entire community; 3. A planned and integrated comprehensive transportation system providing for a separation of pedestrian and vehicular traffic, to include facilities such as roadways, bicycle ways, and pedestrian walkways; 4. The provisions of cultural or recreational facilities for all segments of the community; 5. The location of general building envelopes to take maximum advantage of the natural and manmade environment; and 6. The staging of development in a manner which can be accommodated by the timely provision of public utilities, facilities, and services. This PUD serves to augment and/or modify the standards for development outlined in the City’s Unified Development Code (UDC) in order to implement the vision for the property and insure a cohesive, quality development not otherwise anticipated by the underlying base zoning district. In accordance with UDC Section 4.06.010.C “Development Plan Required”, this Development Plan titled Exhibit A is a summary of the development and design standards for the property. C. PLATTING REQUIREMENTS All development subject to this PUD shall process and have approved (and recorded) Preliminary and Final Plats per the subdivision platting regulations of the Unified Development Code. Exemptions from Required Plat under Section 3.08.020 shall not be exercised. D. DEVELOPMENT ZONES For the purposes of this PUD, the Property is divided into three (3) Development Zones as shown on Exhibit D, being Zone A, Zone B, and Zone C. The Development Zones are defined as follows:  Zone A – Zone A represents approximately 10.98 acres of land generally depicted as the southern section of the Property, south of the Major Collector.  Zone B – Zone B consists of approximately 27.81 acres of land and is generally depicted as the middle section of the Property, north of the Major Collector.  Zone C – Zone C consists of approximately 39.49 acres of land and is generally depicted as the northern section of the Property. Page 45 of 80 E. APPLICABILITY AND BASE ZONING In accordance with UDC Section 4.06.010.A “Compatibility with Base Zoning District”, all development of the property shall conform to the base zoning district of each Development Zone unless otherwise noted within this Development Plan. The base zoning district for each zone shall be as follows:  Zone A – General Commercial District (C-3)  Zone B – Residential Single-Family (RS). .  Zone C – High Density Multifamily (MF-2) Except for those requirements specifically deviated by this Development Plan, all development standards established in the most current version of the UDC at time of development shall be applicable, including amendments or ordinances adopted after the date of this PUD. In the case that this Development Plan does not address a specific item, the City of Georgetown UDC and any other applicable Ordinances shall apply. In the event of a conflict between the regulations of this PUD and the regulations of the base zoning district, the PUD shall control. F. CONCEPTUAL LAND USE PLAN A Conceptual Land Use Plan has been attached to this Development Plan as Exhibit B to illustrate the land use and design intent for the property. The Conceptual Land Use Plan is intended to serve as a guide to illustrate the general vision and design concepts and is not intended to serve as a final document. Approval of this PUD, Development Plan, and Conceptual Land Use Plan does not constitute approval of a Site Development Plan per Section 3.09 of the UDC. G. PERMITTED/EXCLUDED LAND USES & RESIDENTIAL UNIT COUNTS 1. Zone A. The permitted Specific Uses shall be per the C-3 District except as follows: a) Additional Allowed Uses: Automotive Rental Facility (maximum 20 rental vehicles subject to limitations of UDC Section 5.04.020.S). b) Prohibited Uses: Multifamily uses; Group Living uses; Cemeteries; Self-Storage Facilities; Manufactured Housing Sales; Automotive Sales; Outdoor Automotive Parts and Accessories Sales; Recreational Vehicle Sales, Rental or Service; Transportation and Utility Services uses. c) Limitations: See UDC Chapter 5 limitations for the C-3 district. 2. Zone B. The permitted Specific Uses shall be per the RS district except as follows: a) The principal use will be a maximum of 160 Single-family Detached Dwelling units. Page 46 of 80 b) Additional Allowed Uses: Townhouse; Detached Multifamily Dwelling Units; Upper-story Residential; Commercial Day Care; General Restaurant; Drive- through Restaurant; Health Services uses; General Office; General Retail; Personal Services; Dry Cleaning Service (Drop-off Only); Laundromat; Printing, Mailing and Reproduction Services; Fitness Center; Banking and Financial Services; Consumer Repair; Fuel Sales (subject to the limitations of UDC Section 5.04.020.T); Car Wash. c) Prohibited Uses: Cemeteries; Transportation and Utility Services uses. d) Limitations: 1) At least 5,000 square feet of non-residential uses shall be built within Zone B. 2) Non-residential uses are limited to the first 200 feet from NE Inner Loop. 3) The floor-to-area ratio of non-residential uses shall not exceed 0.5. 4) Lots containing single-family uses shall be setback at least 50 feet from NE Inner Loop. 5) Lots containing detached multifamily uses shall be setback at least 25 feet from NE Inner Loop. 6) All of these uses shall meet the standards and limitations of the C -1 District. 3. Zone C. The permitted Specific Uses shall be per the MF-2 district except as follows: a) Additional Allowed Uses: Townhouse; Detached Multifamily Dwelling Units; General Restaurant; General Office; General Retail; Personal Services; Dry Cleaning Service (Drop-off Only); Fitness Center. b) Prohibited Uses: Transportation and Utility Services uses. c) Limitations: 1) Non-residential uses are limited to the first 200 feet from NE Inner Loop. 2) The floor-to-area ratio of non-residential uses shall not exceed 0.5. 3) See Section P regarding Open Space.. H. DIMENSIONAL & DESIGN STANDARDS The dimensional and design standards for development shall conform to those of the base zoning district of the Development Zone except as stated below. 1. General. a) Townhouse development in Zone B and Zone C shall comply with the dimensional and design standards of the Townhouse (TH) zoning district as outlined in UDC Section 6.03.070, except as modified in this Development Plan. b) Detached multifamily development in Zone B shall comply with the dimensional and design standards of the Low Density Multifamily (MF-1) Page 47 of 80 zoning district as outlined in UDC Section 6.03.080, except as modified in this Development Plan. c) Non-residential development in Zone B and Zone C shall comply with the dimensional and design standards for the Local Commercial (C-1) zoning district as outlined in UDC Section 7.03, except as modified in this Development Plan. 2. Density. a) Detached multifamily uses in Zone B shall not exceed 14 units per acre. b) Multifamily uses in Zone C shall not exceed 24 units per acre. 3. Building Setbacks. The building setbacks on the Property shall be as follows: a) Buildings and parking for non-residential uses shall be set back a minimum of 50 feet from the westernmost boundary of the Property for all Development Zones. b) Buildings and parking for all uses shall be set back a minimum of 25 feet along Inner Loop Road in all Development Zones. c) Side and rear setbacks for detached multifamily development in Zone B shall be 10 feet adjacent to single-family residential development.. d) Internal building setbacks are not required between residential and non- residential uses within this development when developed as part of a mixed- use project (multi-lot unified development) that satisfies all other use requirements (parking, etc.). 4. Building Height. The maximum building heights on the Property shall be in accordance with the base zoning district of the Deve lopment Zone except as stated below. a) Maximum building height for Zone C is 55’ as defined by the 2012 IBC. 5. Building Design. a) All development except single-family detached dwelling units and detached multifamily structures shall comply with the Building Design Standards in UDC Section 7.04. b) The minimum building separation between multifamily and accessory structures in Zone B or Zone C shall be 10 feet. c) The maximum multifamily dwelling units per building in Zone C shall be 36 units. 6. Fencing. a) A minimum 6-foot tall masonry wall shall be required for any single-family detached dwelling units or townhouse development area within 100 feet of NE Inner Loop. Page 48 of 80 b) Fenced areas within Zone C shall be exclusive of the Private Open Space Lot; it shall not be fenced off and shall remain accessible to the general public. 7. Exterior Lighting. Exterior Lighting on the Property and its buildings will comply with the requirements set forth in Section 7.05 of the UDC related to outdoor lighting unless otherwise described in this PUD. I. PARKING. Parking on the Property shall be in conformance with Chapter 9 of the UDC except as otherwise stated in this Development Plan. a) Parking for multi-family will be:  1.5 spaces for 1 bedroom units  2.0 spaces for 2 bedroom units  2.5 spaces for 3 bedroom units  5% of the total required spaces for guest parking J. VEHICULAR ACCESS AND CIRCULATION 1. General. a) The improvements within this PUD will be designed to maximize pedestrian and vehicular circulation within the Property. b) This PUD will include pedestrian and vehicular circulation plans designed to provide access through all areas within the Property. c) After final approval of this PUD, the general alignment of proposed internal pedestrian and vehicular circulation may be modified from the proposed rendering shown in Exhibit B to accommodate Building locations on the approved Site Development Plan(s) and for the protection of trees and fire safety requirements. Design Details for public streets on the Property shall conform to Chapter 12 of the UDC. 2. Roadways. a) Three (3) roadway intersections are allowed on Inner Loop Road, one being the Major collector requirement b) Design of roadway intersections listed above shall be determined as per the approved TIA. c) Residential development shall allow for a connection to the future Major Collector. 3. Driveway Access. a) Connectivity to the private drive (Wilbarger) along the Western edge of the property is not required as it will gain access from the Future Collector. No Page 49 of 80 connectivity is required to adjacent properties for this development. No lots shall take access from Wilbarger private drive. b) Secondary access to Zone C multi-family shall be provided through single family Zone B at minimum per fire code . K. TREE PRESERVATION Tree Preservation on the Property shall be in conformance with Chapter 8 of the Unified Development Code unless otherwise stated in this Development Plan . Due to: 1. The concentration of Heritage Trees in one location on the property in Zone C 2. The set-aside of private open space Of the fifty (50) identified Heritage Trees, up to three (3) heritage trees may be removed without further approvals and by following the standard mitigation requirements during site plan process. Building placement and setbacks may be adjusted in order to save trees. Due to the uncertainty of the final water quality and detention plans, the Urban Forester shall have full responsibility for approval of all tree removal and mitigation, including heritage trees, associated with these facilities. L. LANDSCAPE AND BUFFER REQUIREMENTS Landscaping on the Property shall be in conformance with Chapter 8 of the UDC unless otherwise stated in this Development Plan. 1. Bufferyards. Bufferyards shall not be required except when non-residential development is adjacent to existing external single-family development. 2. Residential Landscaping. Residential landscaping shall be in accordance with UDC Section 8.03 and the City’s Water Conservation Ordinance. 3. Landscape Maintenance. A property owners’ association will maintain landscaping and irrigation in the rights of way and common areas on the Property. M. SIGNAGE Signage on the Property shall be in conformance with Chapter 10 of the Unified Development Code unless otherwise stated in this Development Plan or in a Master Sign Plan for the Property. 1. A Master Sign Plan, meeting the requirements of Chapter 10 of the UDC, shall be required for this development at time of Site Plan. This PUD proposes additional signage standards that, where in conflict with the provisions of Chapter 10, shall prevail. The Master Sign Plan will serve to implement signs uniformly as a means of clear visual communication, and is intended to cause the designs of any signs on the Page 50 of 80 Property to be complementary to the natural environment, and to improve pedestrian and vehicular safety. 2. Up to four (4) Development Identification Signs may be designed, developed and placed in a median in the public right-of-way of the Major Collector of the Property and at the four (4) corners of the development, more specifically within the median or on the two corners at Inner Loop at the Major Collector intersection, at the Northernmost edge and the Southernmost edge of the property adjacent to NE Inner Loop, subject to site triangle analysis and approval of a License to Encroach. Subdivision Entry Signs on the property shall not be subject to a 5-foot setback from the public right-of way, provided the signage does not obstruct the site triangles. Where advertising four (4) or more tenants, each Development Identification Sign may be a maximum of ten (10) feet in height and be allowed a maximum of eighty (80) square feet for each of the four (4) permitted sign faces to advertise the tenants of the development. Refer to Exhibit J for Signage details. N. IMPERVIOUS COVERAGE Impervious coverage on the Property shall be in conformance with Chapter 11 of the Unified Development Code unless otherwise stated in this Development Plan. Due to the fact that Water Quality and Detention f acilities, if required, will be regional and located in a separate parcel, development of all remaining parcels will not be limited spatially by individual ponds. Impervious cover for the open space lot will be allocated by a percentage increase per land use in accordance with the following: MAXIMUM IMPERVIOUS COVER ALLOWED PER LAND USE LAND USE ALLOWABLE I.C. Parkland 30% Residential (multi-family) 60% Residential (single family) 55% Non-residential 80% O. STORMWATER Stormwater management on the Property shall be in conformance with Chapter 11 of the Unified Development Code unless otherwise stated in this Development Plan. Water Quality. A portion of the Property is located within the Edwards Aquifer Recharge Zone according the TCEQ USGS Quad Map. The Property must comply with the requirements of Chapter 11 of the UDC and the Edwards Aquifer Rules of the Texas Commission on Environmental Quality (TCEQ). Water Quality and Detention are allowed Page 51 of 80 and may be located within the slopes adjacent to the tributary with the approval of TCEQ and the City. P. PARKLAND DEDICATION REQUIREMENTS The parkland dedication requirements of UDC Section 13.05 will be met by the provision of a minimum of 2.0 acres of public park land, and improvements to the parkland per below. 1. Public Parkland Calculations: a) Two (2.0) acres of parkland will be provided for the 160 maximum single - family detached dwelling units (includes single family unit structures developed in a multifamily regime, be it rental or ownership) proposed to be developed in Zone B. The acreage is based on the calculations of: b) One (1.0) acre for every 50 dwelling units = 3.2 acres; c) A deduction of 60 dwelling units, per the UDC Section 8.05.020(A.2) allowance for a 15 lot reduction of dedicated parkland for the preservation of a Heritage Tree, for which four (4) will be included in the parkland and thus owned, maintained, and preserved by the City. d) A net dedication of 2.0 acres. Parkland Dedication fee-in-lieu contributions for Multifamily Dwelling Units developed in Zone C shall be covered by the improvements noted below in subsection (3.). Parkland Dedication fee-in-lieu contributions for any non-single-family detached dwelling units/structures developed in Zone B or Zone C shall pay $250 per unit into Parkland Zone 13 at the time of Final Plat recordation creating the lot(s) for those unit(s). 2. Timing of Land Dedication: The dedication of the above calculated parkland shall be dedicated with the first Final Plat for development subject to this PUD, following all of the applicable subdivision regulations, in particular public access. Applicant may request a waiver or variance to waive lot frontage for parkland tract at the time of first Final Plat if the plat is within Zone 3. In such a circumstance, a public street in public right-of-way shall be provided prior to the the improvements and timing thereof, as described in subsection 5. 3. Improvements to the Parkland: The following constitutes the improvements to be provided by the developer: a) Improvements shall include, but not be limited to: playground equipment, picnic areas, pavilions, trails, etc. Parkland improvement plans must be approved by the Parks Director. A minimum installed value of $60,000, as qualified by the Parks Director, will be used toward the above described improvements. Page 52 of 80 b) Public access via a platted, dedicated roadway of, at a minimum, a Local Street Standard per the UDC and/or other City development regulations, shall be provided. c) Public parking of at least six (6) off-street parking spaces, located and designed in conjunction with the City Development Engineer through the Preliminary Plat Infrastructure Construction Plan review process, shall be provided within the calculated Parkland and immediately accessible to the public street or as parallel spaces along the access road to the park. 4. Trail/Sidewalk access to Parkland: A 10’ trail shall be provided in some combination of sidewalk on one side (determined by the developer in agreement with the City Development Engineer and/or Transportation staff) of a roadway providing public vehicular access to the parkland and/or through open space from Inner Loop commensurate with the parkland improvements in lieu of the required sidewalk per UDC Table 12.03.020. A sidewalk on the side of the street opposite this trail is required per the UDC. 5. Timing of Improvements to the Parkland The above described improvements shall be completed, and the parkland open to the public, and any and all obligations, deeds, etc. related to the parkland conveyed to the City, prior to the sooner of June 1, 2019, or Final Certificate of Occupancy for the last multi-family building in Zone 3, or the issuance of the 30th single-family residential building permit, whichever comes first. Q. Private Open Space Lot: Within Zone C, a non-development lot of no less than 20.00 acres, designated as private open space in the lot summary table on the plat, shall be created on a preliminary and Final Plat. A note on the preliminary and final plats creating this lot shall state “Lot [x] shall be reserved for the purpose of a natural trail as described in Ordinance 2016 -xxx, and shall contain no development features of or for any other lot within this subdivision, notwithstanding drainage easements, structures or other utility structures (including lift stations).” R. Common Amenity Area. The Common Amenity Area requirements of UDC Section 6.06.020 will be met by integrating the following amenities on -site: 1. On-site pool and clubhouse (multi-family only). Page 53 of 80 2. The trail described in (P.) above may count as one (1) of the required on-site Common Amenity/Recreation Area requirements. S. PUD MODIFICATIONS In conformance with Section 4.06.010.D.3 of the UDC, modifications to this Development Plan shall require City Council approval of an amendment to this PUD processed pursuant to Section 3.06 of the UDC, except, where the Director of Planning determines s uch modifications to be minor, the Director may authorize such modifications. Minor modifications may include changes to Development Zones sizes (up to 5% by acreage),building sizes, uses, or locations providing those modifications conform to the general intent of this PUD, uses authorized by this PUD, or to applicable provisions of the UDC and any other applicable regulations. T. FIRE STATION A 2.0 Acre Fire Station site will be dedicated as shown on Exhibit B and at the time requested by the City. In the event that the City decides against constructing a fire station at this location, the 2- acre property shall be allowed the uses and design standards of the underlying C-3 zoning district and as specified in Zone A. U. LIST OF EXHIBITS Exhibit A – This PUD Development Plan Exhibit B - Conceptual Land Use Plan & Circulation Exhibit C - Property Map with Existing Tract or Lot Lines Designated Exhibit D - Property Map with Zone Designations Outlined Exhibit E - Property Map with Building Setbacks Outlined Exhibit F - Tree Survey and Tree Details Exhibit G - Field Notes Identifying the Property Exhibit H - Existing Natural Features Exhibit I - Signage Details Page 54 of 80 SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . 1 76 6 . 5 8 3 3 " l o 2 76 6 . 5 9 1 7 " l o 3 76 6 . 2 8 2 5 " e l m 4 7 6 5 . 7 7 19 " e l m 5 76 5 . 3 7 1 5 " e l m 7 7 6 4 . 9 2 1 6 " e l m 8 7 6 4 . 5 8 22 " e l m 14 7 6 5 . 5 2 1 8 " e l m 1 7 7 6 5 . 8 5 19 " l o 2 0 7 6 6 . 2 5 1 4 " l o 2 7 7 6 5 . 1 9 1 4 " l o 2 9 7 6 5 . 0 4 1 8 " e l m 3 3 76 4 . 9 5 1 7 " l o 34 76 6 . 5 1 2 4 " l o 3 6 7 6 6 . 5 8 20 " l o 3 7 7 6 6 . 3 5 1 3 " e l m 3 8 7 6 6 . 2 8 1 2 " l o 42 7 6 5 . 6 6 19 " e l m 43 7 6 6 . 5 2 18 " l o 44 7 6 7 . 4 4 1 7 " l o 45 7 6 7 . 5 3 2 8 " l o 4 6 76 7 . 5 9 2 2 " l o 4 8 76 7 . 8 3 2 5 " l o 49 7 6 8 . 0 8 2 3 " l o 52 76 9 . 1 4 3 4 " l o 5 3 7 6 8 . 4 6 24 " l o 5 4 76 5 . 9 0 2 6 " l o 5 5 7 6 5 . 7 9 28 " l o 5 7 7 5 9 . 6 9 17 " l o 6 0 7 6 4 . 8 6 1 8 " l o 6 2 7 6 2 . 6 4 lo t r e e s t a n d 6 6 76 6 . 9 8 14 " l o 67 76 6 . 8 7 2 2 " l o 6 8 7 6 5 . 3 0 2 2 " l o 6 9 7 6 8 . 1 0 17 " l o 7 1 76 7 . 6 6 1 8 " l o 7 2 76 7 . 3 5 2 7 " l o 74 77 0 . 1 2 2 0 " e l m 7 5 7 6 8 . 8 9 3 2 " l o 7 6 7 6 8 . 1 4 13 " l o 7 7 7 6 7 . 9 2 34 " l o 78 76 8 . 5 9 2 0 " l o 7 9 7 6 5 . 7 4 1 5 " l o 80 7 6 3 . 7 4 12 " e l m 81 75 9 . 0 9 tr p l l o 8 2 76 0 . 7 2 1 7 " l o 83 7 5 9 . 1 2 17 " e l m 8 4 76 2 . 0 2 d b l l o 8 6 76 5 . 8 6 2 1 " l o 87 76 9 . 0 8 1 4 " e l m 88 76 7 . 5 3 16 " e l m 9 1 7 6 3 . 1 4 1 7 " e l m 10 2 7 5 4 . 2 3 1 8 " l o 10 3 7 5 6 . 9 4 24 " l o 1 0 4 75 7 . 6 6 2 0 " l o 1 0 5 75 5 . 8 9 1 8 " l o 1 0 7 7 6 3 . 7 3 2 2 " l o 1 0 8 75 6 . 9 0 tr p l l o 1 0 9 7 6 3 . 2 5 q u i n t l o 11 1 75 3 . 4 9 2 4 " l o 1 1 2 75 5 . 6 2 d b l l o 1 1 3 7 6 0 . 4 3 16 " e l m 11 4 7 6 1 . 1 2 1 8 " e l m 1 1 5 7 5 7 . 2 2 2 7 " l o 1 1 7 75 7 . 7 7 19 " e l m 11 8 7 4 3 . 4 6 12 " e l m 1 1 9 74 9 . 1 6 1 9 " e l m 12 4 7 6 3 . 9 7 1 5 " e l m 1 2 5 7 2 2 . 3 4 tr p l e l m 1 2 9 6 9 1 . 6 0 d b l l o 1 3 3 7 2 7 . 6 8 13 " e l m 1 3 5 7 3 2 . 1 9 d b l e l m 13 9 7 4 4 . 7 7 1 6 " p o 1 4 2 7 7 1 . 7 5 1 3 " e l m 14 7 77 1 . 5 5 28 " p o 14 9 7 6 7 . 7 3 1 5 " p o 1 5 0 7 6 0 . 0 9 1 8 " p o 15 6 7 6 6 . 5 1 d b l e l m 1 5 7 7 6 9 . 5 1 1 9 " e l m 1 5 8 76 9 . 8 0 1 7 " e l m 16 1 7 7 2 . 9 6 3 5 " l o 16 2 7 7 3 . 5 8 35 " l o 1 6 3 77 3 . 9 1 3 6 " l o 16 4 7 7 2 . 8 9 4 3 " l o 16 5 7 7 2 . 1 0 2 2 " l o 16 8 7 7 2 . 5 9 2 0 " e l m 1 6 9 76 8 . 4 9 1 6 " e l m 17 6 7 7 6 . 5 4 d b l l o 17 7 7 7 8 . 4 1 27 " l o 1 7 9 7 7 2 . 3 2 23 " l o 1 8 0 75 4 . 9 1 1 2 " e l m 94 7 5 3 . 0 0 3 2 " l o 6 7 6 5 . 1 4 1 2 " e l m 9 76 3 . 6 0 2 1 " l o 1 0 7 6 2 . 7 9 d b l l o 1 1 76 2 . 7 9 16 " e l m 1 2 7 6 2 . 1 5 24 " l o 13 7 6 4 . 1 4 d b l l o 1 5 76 5 . 8 8 16 " l o 1 6 7 6 6 . 4 7 tr p l l o 1 8 7 6 6 . 1 1 d b l l o 1 9 76 5 . 3 6 1 2 " l o 21 7 6 7 . 3 1 d b l l o 2 2 76 5 . 4 0 1 6 " l o 2 3 76 5 . 5 2 13 " l o 2 4 7 6 5 . 4 9 13 " l o 2 5 7 6 5 . 2 6 1 2 " e l m 2 6 76 1 . 4 6 14 " e l m 2 8 7 6 1 . 2 9 2 2 " l o 30 76 6 . 9 6 d b l l o 3 1 76 5 . 2 1 d b l l o 32 7 6 5 . 3 0 d b l l o 3 5 76 7 . 2 3 d b l l o 3 9 7 6 6 . 5 8 14 " l o 4 0 7 6 6 . 5 9 17 " l o 4 1 7 6 6 . 2 1 1 6 " e l m 47 7 6 8 . 8 2 d b l l o 5 0 7 6 8 . 6 6 37 " l o 51 7 6 8 . 2 3 32 " l o 5 6 7 6 0 . 1 2 3 2 " l o 5 8 76 3 . 5 3 d b l l o 59 7 6 4 . 8 0 d b l l o 61 7 6 1 . 6 8 d b l l o 6 3 7 6 1 . 5 5 lo t r e e s t a n d 64 76 1 . 1 3 lo t r e e s t a n d 6 5 7 6 1 . 6 2 lo t r e e s t a n d 7 0 76 7 . 7 8 2 7 " l o 8 5 76 2 . 6 8 2 9 " l o 89 7 6 8 . 9 8 2 4 " l o 9 0 7 6 3 . 2 4 d b l e l m 9 2 76 3 . 2 0 1 5 " e l m 1 0 1 7 5 3 . 8 4 d b l l o 1 0 6 76 1 . 6 4 d b l l o 1 1 0 75 4 . 9 6 1 4 " l o 1 1 6 76 5 . 1 9 1 5 " l o 1 2 3 7 6 0 . 4 0 2 1 " e l m 1 4 1 7 7 0 . 1 7 1 4 " e l m 1 4 3 7 6 9 . 8 2 16 " p o 1 4 4 7 6 7 . 7 5 12 " e l m 1 4 8 7 7 1 . 3 5 21 " p o 1 5 1 7 5 8 . 5 3 2 1 " p o 1 5 2 75 1 . 0 1 1 4 " e l m 1 5 3 74 7 . 4 5 1 6 " l o 15 4 76 4 . 2 1 2 3 " l o 15 5 7 6 2 . 4 7 1 4 " e l m 15 9 7 6 6 . 0 0 1 3 " e l m 1 6 6 7 7 2 . 6 3 3 5 " l o 16 7 77 2 . 0 4 41 " l o 17 0 7 6 9 . 4 0 17 " e l m 1 7 1 76 8 . 2 8 1 6 " l o 17 8 76 9 . 9 6 3 8 " l o M A J O R C O L L E C T O R COMMERCIAL CIVIC MULTI-FAMILY LEGEND RESIDENTIAL VEHICULAR CIRCULATION PEDESTRIAN CIRCULATION COMMERCIAL MIXED USE 3.12 AC RESIDENTIAL 24.00 AC MULTI-FAMILY 15.30 ACPARK 2.19 AC OPEN SPACE 21.99 AC FIRE STATION 2.00 AC COMMERCIAL 8.31 AC NE I N N E R L O O P W I L B A R G E R P O I N T Pr o p e r t y M a p w i t h C o n c e p t u a l L a n d U s e P l a n & C i r c u l a t i o n BGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com Page 55 of 80 SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . NE I N N E R L O O P W I L B A R G E R P O I N T PR O P E R T Y M A P W I T H E X I S T I N G T R A C T O R L O T L I N E S D E S I G N A T E D CGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com Page 56 of 80 SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . 1 76 6 . 5 8 3 3 " l o 2 76 6 . 5 9 1 7 " l o 3 76 6 . 2 8 2 5 " e l m 4 7 6 5 . 7 7 19 " e l m 5 76 5 . 3 7 1 5 " e l m 7 7 6 4 . 9 2 1 6 " e l m 8 7 6 4 . 5 8 22 " e l m 14 7 6 5 . 5 2 1 8 " e l m 1 7 7 6 5 . 8 5 19 " l o 2 0 7 6 6 . 2 5 1 4 " l o 2 7 7 6 5 . 1 9 1 4 " l o 2 9 7 6 5 . 0 4 1 8 " e l m 3 3 76 4 . 9 5 1 7 " l o 34 76 6 . 5 1 2 4 " l o 3 6 7 6 6 . 5 8 20 " l o 3 7 7 6 6 . 3 5 1 3 " e l m 3 8 7 6 6 . 2 8 1 2 " l o 42 7 6 5 . 6 6 19 " e l m 43 7 6 6 . 5 2 18 " l o 44 7 6 7 . 4 4 1 7 " l o 45 7 6 7 . 5 3 2 8 " l o 4 6 76 7 . 5 9 2 2 " l o 4 8 76 7 . 8 3 2 5 " l o 49 7 6 8 . 0 8 2 3 " l o 52 76 9 . 1 4 3 4 " l o 5 3 7 6 8 . 4 6 24 " l o 5 4 76 5 . 9 0 2 6 " l o 5 5 7 6 5 . 7 9 28 " l o 5 7 7 5 9 . 6 9 17 " l o 6 0 7 6 4 . 8 6 1 8 " l o 6 2 7 6 2 . 6 4 lo t r e e s t a n d 6 6 76 6 . 9 8 14 " l o 67 76 6 . 8 7 2 2 " l o 6 8 7 6 5 . 3 0 2 2 " l o 6 9 7 6 8 . 1 0 17 " l o 7 1 76 7 . 6 6 1 8 " l o 7 2 76 7 . 3 5 2 7 " l o 74 77 0 . 1 2 2 0 " e l m 7 5 7 6 8 . 8 9 3 2 " l o 7 6 7 6 8 . 1 4 13 " l o 7 7 7 6 7 . 9 2 34 " l o 78 76 8 . 5 9 2 0 " l o 7 9 7 6 5 . 7 4 1 5 " l o 80 7 6 3 . 7 4 12 " e l m 81 75 9 . 0 9 tr p l l o 8 2 76 0 . 7 2 1 7 " l o 83 7 5 9 . 1 2 17 " e l m 8 4 76 2 . 0 2 d b l l o 8 6 76 5 . 8 6 2 1 " l o 87 76 9 . 0 8 1 4 " e l m 88 76 7 . 5 3 16 " e l m 9 1 7 6 3 . 1 4 1 7 " e l m 10 2 7 5 4 . 2 3 1 8 " l o 10 3 7 5 6 . 9 4 24 " l o 1 0 4 75 7 . 6 6 2 0 " l o 1 0 5 75 5 . 8 9 1 8 " l o 1 0 7 7 6 3 . 7 3 2 2 " l o 1 0 8 75 6 . 9 0 tr p l l o 1 0 9 7 6 3 . 2 5 q u i n t l o 11 1 75 3 . 4 9 2 4 " l o 1 1 2 75 5 . 6 2 d b l l o 1 1 3 7 6 0 . 4 3 16 " e l m 11 4 7 6 1 . 1 2 1 8 " e l m 1 1 5 7 5 7 . 2 2 2 7 " l o 1 1 7 75 7 . 7 7 19 " e l m 11 8 7 4 3 . 4 6 12 " e l m 1 1 9 74 9 . 1 6 1 9 " e l m 12 4 7 6 3 . 9 7 1 5 " e l m 1 2 5 7 2 2 . 3 4 tr p l e l m 1 2 9 6 9 1 . 6 0 d b l l o 1 3 3 7 2 7 . 6 8 13 " e l m 1 3 5 7 3 2 . 1 9 d b l e l m 13 9 7 4 4 . 7 7 1 6 " p o 1 4 2 7 7 1 . 7 5 1 3 " e l m 14 7 77 1 . 5 5 28 " p o 14 9 7 6 7 . 7 3 1 5 " p o 1 5 0 7 6 0 . 0 9 1 8 " p o 15 6 7 6 6 . 5 1 d b l e l m 1 5 7 7 6 9 . 5 1 1 9 " e l m 1 5 8 76 9 . 8 0 1 7 " e l m 16 1 7 7 2 . 9 6 3 5 " l o 16 2 7 7 3 . 5 8 35 " l o 1 6 3 77 3 . 9 1 3 6 " l o 16 4 7 7 2 . 8 9 4 3 " l o 16 5 7 7 2 . 1 0 2 2 " l o 16 8 7 7 2 . 5 9 2 0 " e l m 1 6 9 76 8 . 4 9 1 6 " e l m 17 6 7 7 6 . 5 4 d b l l o 17 7 7 7 8 . 4 1 27 " l o 1 7 9 7 7 2 . 3 2 23 " l o 1 8 0 75 4 . 9 1 1 2 " e l m 94 7 5 3 . 0 0 3 2 " l o 6 7 6 5 . 1 4 1 2 " e l m 9 76 3 . 6 0 2 1 " l o 1 0 7 6 2 . 7 9 d b l l o 1 1 76 2 . 7 9 16 " e l m 1 2 7 6 2 . 1 5 24 " l o 13 7 6 4 . 1 4 d b l l o 1 5 76 5 . 8 8 16 " l o 1 6 7 6 6 . 4 7 tr p l l o 1 8 7 6 6 . 1 1 d b l l o 1 9 76 5 . 3 6 1 2 " l o 21 7 6 7 . 3 1 d b l l o 2 2 76 5 . 4 0 1 6 " l o 2 3 76 5 . 5 2 13 " l o 2 4 7 6 5 . 4 9 13 " l o 2 5 7 6 5 . 2 6 1 2 " e l m 2 6 76 1 . 4 6 14 " e l m 2 8 7 6 1 . 2 9 2 2 " l o 30 76 6 . 9 6 d b l l o 3 1 76 5 . 2 1 d b l l o 32 7 6 5 . 3 0 d b l l o 3 5 76 7 . 2 3 d b l l o 3 9 7 6 6 . 5 8 14 " l o 4 0 7 6 6 . 5 9 17 " l o 4 1 7 6 6 . 2 1 1 6 " e l m 47 7 6 8 . 8 2 d b l l o 5 0 7 6 8 . 6 6 37 " l o 51 7 6 8 . 2 3 32 " l o 5 6 7 6 0 . 1 2 3 2 " l o 5 8 76 3 . 5 3 d b l l o 59 7 6 4 . 8 0 d b l l o 61 7 6 1 . 6 8 d b l l o 6 3 7 6 1 . 5 5 lo t r e e s t a n d 64 76 1 . 1 3 lo t r e e s t a n d 6 5 7 6 1 . 6 2 lo t r e e s t a n d 7 0 76 7 . 7 8 2 7 " l o 8 5 76 2 . 6 8 2 9 " l o 89 7 6 8 . 9 8 2 4 " l o 9 0 7 6 3 . 2 4 d b l e l m 9 2 76 3 . 2 0 1 5 " e l m 1 0 1 7 5 3 . 8 4 d b l l o 1 0 6 76 1 . 6 4 d b l l o 1 1 0 75 4 . 9 6 1 4 " l o 1 1 6 76 5 . 1 9 1 5 " l o 1 2 3 7 6 0 . 4 0 2 1 " e l m 1 4 1 7 7 0 . 1 7 1 4 " e l m 1 4 3 7 6 9 . 8 2 16 " p o 1 4 4 7 6 7 . 7 5 12 " e l m 1 4 8 7 7 1 . 3 5 21 " p o 1 5 1 7 5 8 . 5 3 2 1 " p o 1 5 2 75 1 . 0 1 1 4 " e l m 1 5 3 74 7 . 4 5 1 6 " l o 15 4 76 4 . 2 1 2 3 " l o 15 5 7 6 2 . 4 7 1 4 " e l m 15 9 7 6 6 . 0 0 1 3 " e l m 1 6 6 7 7 2 . 6 3 3 5 " l o 16 7 77 2 . 0 4 41 " l o 17 0 7 6 9 . 4 0 17 " e l m 1 7 1 76 8 . 2 8 1 6 " l o 17 8 76 9 . 9 6 3 8 " l o ZONE 'B' 27.81 AC. ZONE 'A' 10.98 AC. ZONE 'C' 39.49 AC. NE I N N E R L O O P W I L B A R G E R P O I N T PR O P E R T Y M A P W I T H Z O N E D E S I G N A T I O N S O U T L I N E D DGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com Page 57 of 80 SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . NE I N N E R L O O P W I L B A R G E R P O I N T Pr o p e r t y M a p w i t h B u i l d i n g S e t b a c k s O u t l i n e d EGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com Page 58 of 80 F Page 59 of 80 GPage 60 of 80 GPage 61 of 80 GPage 62 of 80 GPage 63 of 80 GPage 64 of 80 GPage 65 of 80 GPage 66 of 80 GPage 67 of 80 GPage 68 of 80 GPage 69 of 80 SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . 1 76 6 . 5 8 3 3 " l o 2 76 6 . 5 9 1 7 " l o 3 76 6 . 2 8 2 5 " e l m 4 7 6 5 . 7 7 19 " e l m 5 76 5 . 3 7 1 5 " e l m 7 7 6 4 . 9 2 1 6 " e l m 8 7 6 4 . 5 8 22 " e l m 14 7 6 5 . 5 2 1 8 " e l m 1 7 7 6 5 . 8 5 19 " l o 2 0 7 6 6 . 2 5 1 4 " l o 2 7 7 6 5 . 1 9 1 4 " l o 2 9 7 6 5 . 0 4 1 8 " e l m 3 3 76 4 . 9 5 1 7 " l o 34 76 6 . 5 1 2 4 " l o 3 6 7 6 6 . 5 8 20 " l o 3 7 7 6 6 . 3 5 1 3 " e l m 3 8 7 6 6 . 2 8 1 2 " l o 42 7 6 5 . 6 6 19 " e l m 43 7 6 6 . 5 2 18 " l o 44 7 6 7 . 4 4 1 7 " l o 45 7 6 7 . 5 3 2 8 " l o 4 6 76 7 . 5 9 2 2 " l o 4 8 76 7 . 8 3 2 5 " l o 49 7 6 8 . 0 8 2 3 " l o 52 76 9 . 1 4 3 4 " l o 5 3 7 6 8 . 4 6 24 " l o 5 4 76 5 . 9 0 2 6 " l o 5 5 7 6 5 . 7 9 28 " l o 5 7 7 5 9 . 6 9 17 " l o 6 0 7 6 4 . 8 6 1 8 " l o 6 2 7 6 2 . 6 4 lo t r e e s t a n d 6 6 76 6 . 9 8 14 " l o 67 76 6 . 8 7 2 2 " l o 6 8 7 6 5 . 3 0 2 2 " l o 6 9 7 6 8 . 1 0 17 " l o 7 1 76 7 . 6 6 1 8 " l o 7 2 76 7 . 3 5 2 7 " l o 74 77 0 . 1 2 2 0 " e l m 7 5 7 6 8 . 8 9 3 2 " l o 7 6 7 6 8 . 1 4 13 " l o 7 7 7 6 7 . 9 2 34 " l o 78 76 8 . 5 9 2 0 " l o 7 9 7 6 5 . 7 4 1 5 " l o 80 7 6 3 . 7 4 12 " e l m 81 75 9 . 0 9 tr p l l o 8 2 76 0 . 7 2 1 7 " l o 83 7 5 9 . 1 2 17 " e l m 8 4 76 2 . 0 2 d b l l o 8 6 76 5 . 8 6 2 1 " l o 87 76 9 . 0 8 1 4 " e l m 88 76 7 . 5 3 16 " e l m 9 1 7 6 3 . 1 4 1 7 " e l m 10 2 7 5 4 . 2 3 1 8 " l o 10 3 7 5 6 . 9 4 24 " l o 1 0 4 75 7 . 6 6 2 0 " l o 1 0 5 75 5 . 8 9 1 8 " l o 1 0 7 7 6 3 . 7 3 2 2 " l o 1 0 8 75 6 . 9 0 tr p l l o 1 0 9 7 6 3 . 2 5 q u i n t l o 11 1 75 3 . 4 9 2 4 " l o 1 1 2 75 5 . 6 2 d b l l o 1 1 3 7 6 0 . 4 3 16 " e l m 11 4 7 6 1 . 1 2 1 8 " e l m 1 1 5 7 5 7 . 2 2 2 7 " l o 1 1 7 75 7 . 7 7 19 " e l m 11 8 7 4 3 . 4 6 12 " e l m 1 1 9 74 9 . 1 6 1 9 " e l m 12 4 7 6 3 . 9 7 1 5 " e l m 1 2 5 7 2 2 . 3 4 tr p l e l m 1 2 9 6 9 1 . 6 0 d b l l o 1 3 3 7 2 7 . 6 8 13 " e l m 1 3 5 7 3 2 . 1 9 d b l e l m 13 9 7 4 4 . 7 7 1 6 " p o 1 4 2 7 7 1 . 7 5 1 3 " e l m 14 7 77 1 . 5 5 28 " p o 14 9 7 6 7 . 7 3 1 5 " p o 1 5 0 7 6 0 . 0 9 1 8 " p o 15 6 7 6 6 . 5 1 d b l e l m 1 5 7 7 6 9 . 5 1 1 9 " e l m 1 5 8 76 9 . 8 0 1 7 " e l m 16 1 7 7 2 . 9 6 3 5 " l o 16 2 7 7 3 . 5 8 35 " l o 1 6 3 77 3 . 9 1 3 6 " l o 16 4 7 7 2 . 8 9 4 3 " l o 16 5 7 7 2 . 1 0 2 2 " l o 16 8 7 7 2 . 5 9 2 0 " e l m 1 6 9 76 8 . 4 9 1 6 " e l m 17 6 7 7 6 . 5 4 d b l l o 17 7 7 7 8 . 4 1 27 " l o 1 7 9 7 7 2 . 3 2 23 " l o 1 8 0 75 4 . 9 1 1 2 " e l m 94 7 5 3 . 0 0 3 2 " l o 6 7 6 5 . 1 4 1 2 " e l m 9 76 3 . 6 0 2 1 " l o 1 0 7 6 2 . 7 9 d b l l o 1 1 76 2 . 7 9 16 " e l m 1 2 7 6 2 . 1 5 24 " l o 13 7 6 4 . 1 4 d b l l o 1 5 76 5 . 8 8 16 " l o 1 6 7 6 6 . 4 7 tr p l l o 1 8 7 6 6 . 1 1 d b l l o 1 9 76 5 . 3 6 1 2 " l o 21 7 6 7 . 3 1 d b l l o 2 2 76 5 . 4 0 1 6 " l o 2 3 76 5 . 5 2 13 " l o 2 4 7 6 5 . 4 9 13 " l o 2 5 7 6 5 . 2 6 1 2 " e l m 2 6 76 1 . 4 6 14 " e l m 2 8 7 6 1 . 2 9 2 2 " l o 30 76 6 . 9 6 d b l l o 3 1 76 5 . 2 1 d b l l o 32 7 6 5 . 3 0 d b l l o 3 5 76 7 . 2 3 d b l l o 3 9 7 6 6 . 5 8 14 " l o 4 0 7 6 6 . 5 9 17 " l o 4 1 7 6 6 . 2 1 1 6 " e l m 47 7 6 8 . 8 2 d b l l o 5 0 7 6 8 . 6 6 37 " l o 51 7 6 8 . 2 3 32 " l o 5 6 7 6 0 . 1 2 3 2 " l o 5 8 76 3 . 5 3 d b l l o 59 7 6 4 . 8 0 d b l l o 61 7 6 1 . 6 8 d b l l o 6 3 7 6 1 . 5 5 lo t r e e s t a n d 64 76 1 . 1 3 lo t r e e s t a n d 6 5 7 6 1 . 6 2 lo t r e e s t a n d 7 0 76 7 . 7 8 2 7 " l o 8 5 76 2 . 6 8 2 9 " l o 89 7 6 8 . 9 8 2 4 " l o 9 0 7 6 3 . 2 4 d b l e l m 9 2 76 3 . 2 0 1 5 " e l m 1 0 1 7 5 3 . 8 4 d b l l o 1 0 6 76 1 . 6 4 d b l l o 1 1 0 75 4 . 9 6 1 4 " l o 1 1 6 76 5 . 1 9 1 5 " l o 1 2 3 7 6 0 . 4 0 2 1 " e l m 1 4 1 7 7 0 . 1 7 1 4 " e l m 1 4 3 7 6 9 . 8 2 16 " p o 1 4 4 7 6 7 . 7 5 12 " e l m 1 4 8 7 7 1 . 3 5 21 " p o 1 5 1 7 5 8 . 5 3 2 1 " p o 1 5 2 75 1 . 0 1 1 4 " e l m 1 5 3 74 7 . 4 5 1 6 " l o 15 4 76 4 . 2 1 2 3 " l o 15 5 7 6 2 . 4 7 1 4 " e l m 15 9 7 6 6 . 0 0 1 3 " e l m 1 6 6 7 7 2 . 6 3 3 5 " l o 16 7 77 2 . 0 4 41 " l o 17 0 7 6 9 . 4 0 17 " e l m 1 7 1 76 8 . 2 8 1 6 " l o 17 8 76 9 . 9 6 3 8 " l o NE I N N E R L O O P W I L B A R G E R P O I N T Ex i s t i n g N a t u r a l F e a t u r e s HGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com Page 70 of 80 SIGN INTEGRAL WITH WALL OPTION MEDIAN OR CORNER SIGN OPTION WALL OPTION MA X . 8 ' - 0 " PROJECT LOGO PROJECT LOGO SIGN AREA MAX. 64 S.F. PROJECT LOGO PROJECT LOGO VA R I E S W / D E S I G N 10 ' - M A X . VA R I E S W / D E S I G N VA R I E S W / D E S I G N 4' - M A X VA R I E S W/ D E S I G N NOTE: THIS IS A GRAPHIC REPRESENTATION AND DOES NOT SPECIFY WALL DESIGN OR MATERIALS. NOTE: THIS IS A GRAPHIC REPRESENTATION AND DOES NOT SPECIFY WALL DESIGN OR MATERIALS. PROJECT BOUNDARY FENCING PROJECT BOUNDARY FENCING TRANSITION TO PROJECT ENTRY SIGN PROJECT BOUNDARY FENCING TRANSITION TO PROJECT BOUNDARY FENCING TRANSITION TO PROJECT BOUNDARY FENCING PROJECT ENTRY WALL 4' - M A X PROJECT LOGO MA X . 8 ' - 0 " PROJECT LOGO PROJECT LOGO SIGN AREA MAX. 64 S.F. 10 ' - M A X . NOTE: THIS IS A GRAPHIC REPRESENTATION AND DOES NOT SPECIFY WALL DESIGN OR MATERIALS. TRANSITION PROJECT ENTRY WALL PROJECT LOGO SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y SO U T H W E S T E R N U N I V E R S I T Y L.A . C R A B B I I I DE B O R A H SP A R K M A N TO M M I E ED W A R D NO R R E L L JIM M Y L Y N N A N D SU S A N J . S N O W GE N E L A W H O N GE N E L A W H O N RIC H A R D MC C U L L O U G H FU T U R E C O M M E R C I A L S E C T I O N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 6 8 . 1 0 8 A C . 8. 1 8 4 A C . 1. 9 9 4 A C . 1 76 6 . 5 8 33 " l o 2 76 6 . 5 9 17 " l o 3 76 6 . 2 8 25 " e l m 4 76 5 . 7 7 19 " e l m 5 76 5 . 3 7 15 " e l m 7 76 4 . 9 2 16 " e l m 8 76 4 . 5 8 22 " e l m 14 76 5 . 5 2 18 " e l m 17 76 5 . 8 5 19 " l o 20 76 6 . 2 5 14 " l o 27 76 5 . 1 9 14 " l o 29 76 5 . 0 4 18 " e l m 33 76 4 . 9 5 17 " l o 34 76 6 . 5 1 24 " l o 36 76 6 . 5 8 20 " l o 37 76 6 . 3 5 13 " e l m 38 76 6 . 2 8 12 " l o 42 76 5 . 6 6 19 " e l m 43 76 6 . 5 2 18 " l o 44 76 7 . 4 4 17 " l o 45 76 7 . 5 3 28 " l o 46 76 7 . 5 9 22 " l o 48 76 7 . 8 3 25 " l o 49 76 8 . 0 8 23 " l o 52 76 9 . 1 4 34 " l o 53 76 8 . 4 6 24 " l o 54 76 5 . 9 0 26 " l o 55 76 5 . 7 9 28 " l o 57 75 9 . 6 9 17 " l o 60 76 4 . 8 6 18 " l o 62 76 2 . 6 4 lo t r e e s t a n d 66 76 6 . 9 8 14 " l o 67 76 6 . 8 7 22 " l o 68 76 5 . 3 0 22 " l o 69 76 8 . 1 0 17 " l o 71 76 7 . 6 6 18 " l o 72 76 7 . 3 5 27 " l o 74 77 0 . 1 2 20 " e l m 75 76 8 . 8 9 32 " l o 76 76 8 . 1 4 13 " l o 77 76 7 . 9 2 34 " l o 78 76 8 . 5 9 20 " l o 79 76 5 . 7 4 15 " l o 80 76 3 . 7 4 12 " e l m 81 75 9 . 0 9 tr p l l o 82 76 0 . 7 2 17 " l o 83 75 9 . 1 2 17 " e l m 84 76 2 . 0 2 db l l o 86 76 5 . 8 6 21 " l o 87 76 9 . 0 8 14 " e l m 88 76 7 . 5 3 16 " e l m 91 76 3 . 1 4 17 " e l m 10 2 75 4 . 2 3 18 " l o 10 3 75 6 . 9 4 24 " l o 10 4 75 7 . 6 6 20 " l o 10 5 75 5 . 8 9 18 " l o 10 7 76 3 . 7 3 22 " l o 10 8 75 6 . 9 0 tr p l l o 10 9 76 3 . 2 5 qu i n t l o 11 1 75 3 . 4 9 24 " l o 11 2 75 5 . 6 2 db l l o 11 3 76 0 . 4 3 16 " e l m 11 4 76 1 . 1 2 18 " e l m 11 5 75 7 . 2 2 27 " l o 11 7 75 7 . 7 7 19 " e l m 11 8 74 3 . 4 6 12 " e l m 11 9 74 9 . 1 6 19 " e l m 12 4 76 3 . 9 7 15 " e l m 12 5 72 2 . 3 4 tr p l e l m 12 9 69 1 . 6 0 db l l o 13 3 72 7 . 6 8 13 " e l m 13 5 73 2 . 1 9 db l e l m 13 9 74 4 . 7 7 16 " p o 14 2 77 1 . 7 5 13 " e l m 14 7 77 1 . 5 5 28 " p o 14 9 76 7 . 7 3 15 " p o 15 0 76 0 . 0 9 18 " p o 15 6 76 6 . 5 1 db l e l m 15 7 76 9 . 5 1 19 " e l m 15 8 76 9 . 8 0 17 " e l m 16 1 77 2 . 9 6 35 " l o 16 2 77 3 . 5 8 35 " l o 16 3 77 3 . 9 1 36 " l o 16 4 77 2 . 8 9 43 " l o 16 5 77 2 . 1 0 22 " l o 16 8 77 2 . 5 9 20 " e l m 16 9 76 8 . 4 9 16 " e l m 17 6 77 6 . 5 4 db l l o 17 7 77 8 . 4 1 27 " l o 17 9 77 2 . 3 2 23 " l o 18 0 75 4 . 9 1 12 " e l m 94 75 3 . 0 0 32 " l o 6 76 5 . 1 4 12 " e l m 9 76 3 . 6 0 21 " l o 10 76 2 . 7 9 db l l o 11 76 2 . 7 9 16 " e l m 12 76 2 . 1 5 24 " l o 13 76 4 . 1 4 db l l o 15 76 5 . 8 8 16 " l o 16 76 6 . 4 7 tr p l l o 18 76 6 . 1 1 db l l o 19 76 5 . 3 6 12 " l o 21 76 7 . 3 1 d b l l o 22 76 5 . 4 0 16 " l o 23 76 5 . 5 2 13 " l o 24 76 5 . 4 9 13 " l o 25 76 5 . 2 6 12 " e l m 26 76 1 . 4 6 14 " e l m 28 76 1 . 2 9 22 " l o 30 76 6 . 9 6 db l l o 31 76 5 . 2 1 db l l o 32 76 5 . 3 0 db l l o 35 76 7 . 2 3 db l l o 39 76 6 . 5 8 14 " l o 40 76 6 . 5 9 17 " l o 41 76 6 . 2 1 16 " e l m 47 76 8 . 8 2 db l l o 50 76 8 . 6 6 37 " l o 51 76 8 . 2 3 32 " l o 56 76 0 . 1 2 32 " l o 58 76 3 . 5 3 d b l l o 59 76 4 . 8 0 db l l o 61 76 1 . 6 8 db l l o 63 76 1 . 5 5 lo t r e e s t a n d 64 76 1 . 1 3 lo t r e e s t a n d 65 76 1 . 6 2 lo t r e e s t a n d 70 76 7 . 7 8 27 " l o 85 76 2 . 6 8 29 " l o 89 76 8 . 9 8 24 " l o 90 76 3 . 2 4 d b l e l m 92 76 3 . 2 0 15 " e l m 10 1 75 3 . 8 4 db l l o 10 6 76 1 . 6 4 db l l o 11 0 75 4 . 9 6 14 " l o 11 6 76 5 . 1 9 15 " l o 12 3 76 0 . 4 0 21 " e l m 14 1 77 0 . 1 7 14 " e l m 14 3 76 9 . 8 2 16 " p o 14 4 76 7 . 7 5 12 " e l m 14 8 77 1 . 3 5 21 " p o 15 1 75 8 . 5 3 21 " p o 15 2 75 1 . 0 1 14 " e l m 15 3 74 7 . 4 5 16 " l o 15 4 76 4 . 2 1 23 " l o 15 5 76 2 . 4 7 14 " e l m 15 9 76 6 . 0 0 13 " e l m 16 6 77 2 . 6 3 35 " l o 16 7 77 2 . 0 4 41 " l o 17 0 76 9 . 4 0 17 " e l m 17 1 76 8 . 2 8 16 " l o 17 8 76 9 . 9 6 38 " l o M A J O R C O L L E C T O R COMMERCIAL CIVIC MULTI-FAMILY LEGEND RESIDENTIAL VEHICULAR CIRCULATION PEDESTRIAN CIRCULATION COMMERCIAL MIXED USE 3.12 AC RESIDENTIAL 24.00 AC MULTI-FAMILY 15.30 ACPARK 2.19 AC OPEN SPACE 21.99 AC ST A T E H I G H W A Y 2 9 FIRE STATION 2.00 AC COMMERCIAL 8.31 AC NE I N N E R L O O P WI L B A R G E R P O I N T Si g n a g e D e t a i l s IGTOWN 120 HOLDINGS PLANNED UNIT DEVELOPMENT FEET 50 100 2000 N Conceptual site plan.Final site plan may vary. PLACE designers, inc. PLANNING | LANDSCAPE | ARCHITECTURE | CONSULTING | ENGINEERING 304 E. MAIN | SUITE 100 | ROUND ROCK | TX | 78664 |T : [512] 238 8912 | F : [512] 238 8913 PLACEdesigners.com DEVELOPMENT SIGN LOCATIONS Page 71 of 80 NE INNER LOOP E U N I V E R S I T Y A V E W IL B A R G E R P T S M I T H C R E E K R D R E T A M A D R I N D I A N C R E E K D R R E I N H A R D T B L V D T O M A H A W K T R L SE I N N ER L O O P T R O T T E R D RASCOTSTCoordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only ¯ Aerial REZ-2013-016 Le ge ndSiteCity Limits 0 0.25 0.5Mi Page 72 of 80 S O U THW E S T E R N B L V D E U N I V E R S I T Y A V E N E I N N E R L O O P E U N I V E R S I T Y A V E Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only ¯ Future Land Use / Overall Transportation Plan Exhibit #2 REZ-2013 -016 Legend Thoroughfare Future Land Use Institutional Regional Commercial Community Commercial Em ployment Center Low Density Residential Mining Mixed Use Community Mixed Use Neighborhood Center Moderate Density Residential Open Space Specialty Mixed Use Area Ag / Rural Residential Existing Collector Existing Freeway Existing Major Arterial Existing Minor Arterial Existing Ramp Proposed Collector Proposed Freeway Propsed Frontage Road Proposed Major Arterial Proposed Minor Arterial Proposed Railroad High Density Residential 0 ¼½¾Mi LegendSiteParcelsCity Lim itsGeorgetown ETJ Page 73 of 80 S O U THW E S T E R N B L V D E U N I V E R S I T Y A V E N E I N N E R L O O P E U N I V E R S I T Y A V E Zoning InformationREZ-2013-016Exhibit #3 Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only Le ge ndSiteParcelsCity LimitsGeorgetown ETJ ¯ 0 ¼½¾MiPage 74 of 80 Georgetown Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 1 of 6 Report Date: November 29, 2016 File No.: REZ-2013-016 Project Planner: Jordan J. Maddox, AICP, Principal Planner Item Details Project Name: Georgetown 120 Holdings Project Address: Inner Loop/University Ave Location: Generally located at the northwest corner of Inner Loop and East University Ave. Total Acreage: 78.28 acres Applicant: Philip Wanke, ASLA - PLACE designers Property Owner: Kasper Family Limited Partnership Existing Use: Undeveloped Existing Zoning: C-3 with conditions Proposed Zoning: Planned Unit Development District (PUD) with base districts of RS, MF-2 and C-3 Future Land Use: Regional Commercial and Mixed-Use Community Overview of Applicant’s Request The subject property is located in the eastern quadrant of the city, near the intersection of Inner Loop and East University Ave. The property was zoned C-3 with conditions in 2007 and the proposed PUD retains some of the original conditions while providing for a greater mix of uses and densities. Single-family and multi-family are proposed to be added to the commercial/retail entitlements, with a flexibility to mix product types and sizes. The applicant and staff have worked to ensure that the City can pursue a fire station on the site as well as an innovative arrangement for public parkland. Site Information Physical Characteristics: The land has two distinct characters. A majority is a flat, treeless pasture that is rimmed on the north and northwest boundaries by heavy oak tree cover and significant topographic change as the property drops down the plateau. Surrounding Properties: Most of the adjoining land is in the City’s incorporated area with the southwestern boundary adjacent to a small unicorporated pocket of ETJ. Page 75 of 80 Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 2 of 6 The surrounding zoning and land uses are as follows: Utilities: Water, wastewater and electric served by the City of Georgetown. Water and wastewater will need to be extended to the site and a plan is in place to provide adequate service for this development. Electric has existing transmission lines on site. Transportation: The subject property has significant frontage on Inner Loop, a current and future arterial on the overall transportation plan (OTP). A future collector that bisects the property in the southernmost region will be built at some point with development of this tract. The Unified Development Code (UDC) requires full dedication and construction of thoroughfares adjacent and/or internal to a property. A Traffic Impact Analysis (TIA) has been performed for the site Master Plan Guidance 2030 Comprehensive Plan: This property is designated as Mixed-Use Community on the 2030 Plan-Future Land Use Map. Mixed-Use Community is described in the 2030 Plan as: “…intended for large tracts of undevel-oped land, which are appropriate for larger scale, creatively planned communities, where a mix of residential types and densities are complemented by supporting retail, small to medium-scale office development, and integrated open spaces, where appropriate. Compatibility among these various uses will be maintained through design standards that address the locations, character and relationships between uses, while affording greater development flexibility than provided by standard zoning district classifications. Instead of specifying a range of allowable residential densities, the residential mixed-use designation encourages a balanced mixture of residential types as the predominant use in this category, at densities consistent with those provided for each housing type in the base residential categories described previously. Development in this category is best served in planned unit development form or specific mixed- use zoning standards.” In order to stage contiguous, compact, and incremental growth of the city over the next two decades, the 2030 Comprehensive Plan establishes a tiered growth framework. The subject property is located in the Tier 1A Growth area. The Tier 1A area is inside the city limits where infrastructure is planned with the 10-year timeframe. Location Zoning Future Land Use Existing Use North Residential (RS) Mixed Use Community Undeveloped South Commercial (C-3) Regional Commercial Undeveloped East Agriculture (AG) and Commercial (C-3) Regional Commercial and Mixed-Use Community Undeveloped West Residential (RS) and ETJ Mixed-Use Community Residential (ETJ) and undeveloped (city) Page 76 of 80 Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 3 of 6 Zoning Districts The PUD Development Plan establishes three base zoning districts, specified by name: • Zone A (C-3, Commercial); • Zone B (RS, Residential Single-family) • Zone C (MF-2, High-Density Multi-family) Each zone allows for slight modifications to the base district uses and standards, as specified in the Development Plan and summarized below. These modifications, allowable by using the PUD vehicle, allow for flexibility to ensure efficient use of the land and adjust to market conditions. Most of the code modifications are to allow additional commercial uses over time while still accommodating a residential allowance, and standards that could flex depending on the ultimate use of the property. Zone A – General Commercial (C-3) The General Commercial District (C-3) is intended to provide a location for general commercial and retail activities that serve the entire community and its visitors. Uses may be large in scale and generate substantial traffic, making the C-3 District only appropriate along freeways and major arterials. This zone prohibits most auto uses and others and additionally provides for a maximum vehicle count of 20 for automotive rental. Zone B - Residential Single-Family District (RS) The Residential Single-family District (RS) is intended for areas of medium density detached single-family houses with a minimum lot size of 5,500 square feet. The RS District contains standards for development that maintain single-family neighborhood characteristics. The District may be located within proximity of neighborhood-friendly commercial and public services and protected from incompatible uses. In addition to the RS base allowances, Zone B also provides for personal service commercial and retail uses, consistent with the C-1 district. Such uses shall be a minimum of 5,000 square feet of Zone B, are allowed only along Inner Loop and have additional setback requirements of 50 feet from the roadway. Zone B also allows for townhouse and detached multi-family. Zone C – High Density Multifamily (MF-2) The High Density Multi-family District (MF-2) is intended for attached multi-family residential development, such as apartments and condominiums, at a density not to exceed 24 dwelling units per acre. The MF-2 District is appropriate in areas designated on the Future Land Use Plan as High Density Residential or one of the Mixed-Use categories. Properties zoned MF-2 should have direct access to major thoroughfares and arterial streets and should not route traffic through lower density residential areas. The MF District is appropriate adjacent to both Residential and Non-Residential Districts and may serve as a transition between single-family districts and more intense commercial districts. Similar to Zone B, Zone C allows for some personal service and general retail uses with the same limitations. Planned Unit Development District (PUD Page 77 of 80 Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 4 of 6 A PUD is designed to be used in conjunction with a designated base zoning district. An application for PUD zoning shall specify the base district(s) and the uses proposed. If no base zoning exists, the base zoning shall be that zoning designation that is most similar to or compatible with the uses proposed for the PUD. Any uses not permitted in the base district shall be specifically identified. The standards and requirements of the specified base district shall apply unless specifically superseded by the standards and requirements of the PUD Development Plan. In addition to the zoning change approval criteria, the Planning and Zoning Commission and City Council shall consider the following specific objectives and criteria for approving the PUD: Rezoning to and development under the PUD District will be permitted only in accordance with the following specific objectives: 1. A variety of housing types, employment opportunities, or commercial services to achieve a balanced community; 2. An orderly and creative arrangement of all land uses with respect to each other and to the entire community; 3. A planned and integrated comprehensive transportation system providing for a separation of pedestrian and vehicular traffic, to include facilities such as roadways, bicycle ways, and pedestrian walkways; 4. The provisions of cultural or recreational facilities for all segments of the community; 5. The location of general building envelopes to take maximum advantage of the natural and manmade environment; and 6. The staging of development in a manner which can be accommodated by the timely provision of public utilities, facilities, and services. The PUD Plan has additional standards and limitations, some more restrictive and some less restrictive than the UDC. Most provisions are a commitment to standards that ensure compatibility between the uses and provide clear development expectations as the project progresses over time. Most of the 50 Heritage Trees will be preserved, both in the parkland, the apartment zone, and the private open space. A Master Sign Plan will be required at the time of first Site Plan that will be cohesive throughout the project. The PUD provides two acres of parkland, with improvements, a 2-acre fire station, and a 20-22 acre private open space lot around the edge of the cliff area that will remain natural with a future trail. The public parkland will contain a 10’ shared-use trail out to Inner Loop sidewalk and connected internally to the rest of the development. Modifications to the UDC are noted as follows: Page 78 of 80 Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 5 of 6 Development Standard Code Requirement PUD Standard External Setback 10 feet residential 25 feet commercial 50 feet to adjacent residential outside of boundary Building Height – MF-2 45 feet 55 feet Impervious Cover Varies per district (outside of Edwards Aquifer) 10% increase per land use with offset provided by 24+ acres of protected open space and parkland Parkland/Trail s/Open Space 1 acre required per 50 units. Or fees-in-lieu at $250 per unit. Development requirements undetermined due to unspecified total residential units. Developer commits to a 2.0 acre parkland with a minimum $60,000 of improvements including playground, pavilion, trails, etc. with parking and public street access Civic Use None required 2-acre fire station dedicated to the City Staff Analysis Staff has determined that the proposed mixed-use development is consistent with the goals and policies of the 2030 Comprehensive Plan. It supports the Overall Transportation Plan, Future Land Use Plan, and Parks Master Plan by providing adequate public facilities for the provided land uses and densities. It supports the Utility Master Plan by providing extensions and master plan facilities and provides at no cost to the City 2 acres of land to provide future fire services to the area. It is a cohesive development with supporting uses that will serve the development and the surrounding area. The standards within provide flexibility and assurance that the development will have commonality. The provided parkland will have immediate amenities benefitting the public and have fantastic tree cover and views of the city skyline. The development is also sensitive to the neighboring properties with a 50-foot setback. The PUD is consistent with the UDC zoning and PUD approval criteria and supports the City’s goals for balanced development and commercial at key intersections. Staff Recommendation: Staff is recommending approval of the PUD. Public Comments No public comments have been received. Page 79 of 80 Planning Department Staff Report Georgetown 120 – REZ-2013-016 Page 6 of 6 Meetings Schedule December 6 – Planning and Zoning Commission public hearing January 10, 2017 – City Council public hearing and ordinance reading January 24, 2017 – City Council final ordinance reading Attachments Exhibit 1 – Location Map Exhibit 2 – Future Land Use Map Exhibit 3 – Zoning Map Exhibit 4 – Aerial Map Page 80 of 80