HomeMy WebLinkAboutAgenda_P&Z_02.16.2016Notice of Meeting for the Planning and Zoning Commission of the City of Georgetown February 16, 2016 at 6:00 PM at 101 E. Seventh Street, Georgetown, Texas 78626 The City of Georgetown is committed to compliance with the Americans with Disabilities Act (ADA). If you require assistance in participating at a public meeting due to a disability, as defined under the ADA, reasonable assistance, adaptations, or accommodations will be provided upon request. Please contact the City at least four (4) days prior to the scheduled meeting date, at (512) 930-3652 or City Hall at 113 East 8th Street for additional information; TTY users route through Relay Texas at 711. Regular Session (This Regular Session may, at any time, be recessed to convene an Executive Session for any purpose authorized by the Open Meetings Act, Texas Government Code 551.) A Call to Order Pledge of Allegiance Comments from the Chair - Welcome and Meeting Procedures Action from Executive Session Public Wishing to Address the Board On a subject that is posted on this agenda: Please fill out a speaker registration form which can be found at the Board meeting. Clearly print your name, the letter of the item on which you wish to speak, and present it to the Staff Liaison, preferably prior to the start of the meeting. You will be called forward to speak when the Board considers that item. On a subject not posted on the agenda: Persons may add an item to a future Board agenda by filing a written request with the Staff Liaison no later than one week prior to the Board meeting. The request must include the speaker's name and the specific topic to be addressed with sufficient information to inform the board and the public. For Board Liaison contact information, please logon to http://government.georgetown.org/category/boards-commissions/. B As of the deadline, no persons were signed up to speak on items other than what was posted on the agenda. Consent Agenda The Statutory Consent Agenda includes non-controversial and routine items that may be acted upon with one single vote. An item may be pulled from the Consent Agenda in order that it be discussed and acted upon individually as part of the Regular Agenda. Page 1 of 68 C Consideration and possible action on a Preliminary Plat of 76.889 acres in the Francis A. Hudson Survey, Abstract No. 295, located in the Extraterritorial Jurisdiction of the City of Georgetown on the west side of FM 1460 north of Westinghouse Road (CR 111), to be known as Teravista Section 401. PP-2015-012 (Mike Elabarger) Legislative Regular Agenda D Consideration and possible action on a Subdivision Plat Waiver, pursuant to Section 3.22 of the Unified Development Code (UDC), to Section 6.02.010.B of the UDC related to frontage on a public street and Section 6.02.040.B related to Block Length for the Highland Estates subdivision being 28.75 acres in the C. Joyner and G. B. Mayhill Surveys located along the east side of CR 262. WAV-2016-001 (Valerie Kreger, AICP, Principal Planner) E Consideration and possible action on a Preliminary Plat of 28.75 acres in the C. Joyner and G. B. Mayhill Surveys located along the east side of CR 262 to be known as Highland Estates. PP-2015- 014 (Valerie Kreger, AICP, Principal Planner) F Action on a request to Rezone 207.147 acres of land in the Addison Survey located at 2750 County Road 110, known as the Kasper Tract, from the Agriculture (AG) District to a Planned Unit Development (PUD) District with a base zoning of Residential Single-family (RS). REZ- 2016-001 (Sofia Nelson, CNU-A, Planning Director) G Discussion Items: Update on the Unified Development Code Advisory Committee (UDCAC) meetings. (Commissioner in Training Bargainer) Update on the Georgetown Transportation Advisory Board (GTAB) meetings. (Commissioner Rankin) Questions or comments from Commissioners-in-Training about the actions and matters considered on this agenda. Discussion regarding Planning & Zoning Commissioner training. Reminder of the March 1, 2016, Planning and Zoning Commission meeting in the Council Chambers located at 101 East 7th Street, starting at 6:00 pm. Adjournment CERTIFICATE OF POSTING I, Shelley Nowling, City Secretary for the City of Georgetown, Texas, do hereby certify that this Notice of Meeting was posted at City Hall, 113 E. 8th Street, a place readily accessible to the general public at all times, on the ______ day of __________________, 2016, at __________, and remained so posted for at least 72 continuous hours preceding the scheduled time of said meeting. ____________________________________ Shelley Nowling, City Secretary Page 2 of 68 City of Georgetown, Texas Planning and Zoning February 16, 2016 SUBJECT: Consideration and possible action on a Preliminary Plat of 76.889 acres in the Francis A. Hudson Survey, Abstract No. 295, located in the Extraterritorial Jurisdiction of the City of Georgetown on the west side of FM 1460 north of Westinghouse Road (CR 111), to be known as Teravista Section 401. PP-2015-012 (Mike Elabarger) ITEM SUMMARY: Background: The applicant proposes to develop 76.889 acres of undeveloped land into 195 residential lots, with 20 lots constituting open space, private parkland, or water quantity/quality. Two phases are proposed, which would create 186 and 9 lots in that order. Public Comment: Public notice is not requirement for a Preliminary Plat. As of the date of this report, no written public comments have been received. Recommended Motion: Approval of the Preliminary Plat of 76.889 acres in the Francis A. Hudson Survey, Abstract No. 295. FINANCIAL IMPACT: None. The applicant has paid the required application fees. SUBMITTED BY: Mike Elabarger, Senior Planner and Sofia Nelson, CNU-A, Planning Director ATTACHMENTS: Description Type Staff Report Cover Memo Exhibit 1 - Location Map Backup Material Exhibit 2 - Proposed Preliminary Plat Backup Material Page 3 of 68 Georgetown Planning Department Staff Report Teravista Section 401 Preliminary Plat Page 1 of 3 Report Date: February 12, 2016 File No: PP-2015-012 Project Planner: Mike Elabarger, Senior Planner Item Details Project Name: Preliminary Plat of Teravista, Section 401 Project Address: Approximately 2600 FM 1460 Location: West side of FM 1460 north of Teravista Crossing (see Exhibit 1) Total Acreage: 76.889 acres Legal Description: 76.889 acres in the Francis A. Hudson Survey, Abstract No. 295 Applicant: John Pickens, P.E., Bury Inc. Property Owner: NNP-Teravista, LLC Contact: John Pickens, P.E., Bury Inc. Proposed Lots: 195 residential and 20 open space lots Streets Proposed: 1,008 linear feet of a Collector street; 11,542 linear feet of Local Streets Parkland: Parkland dedication requirements are met by improvements to the previously dedicated parkland located to the southwest of this plat; see Plat note 16. Heritage Trees: 30 Heritage Trees are located within this plat Existing Use: Undeveloped land, one residence Existing Zoning: Extraterritorial Jurisdiction; no zoning Future Lane Use: Moderate Density Residential Growth Tier: Tier 2 Applicant’s Request The applicant proposes to develop 76.889 acres of undeveloped land into 195 residential lots, with 20 lots constituting open space, private parkland, or water quantity/quality. Two phases are proposed, which would create 186 and 9 lots in that order. Site Information Location: The property is located on the west side of Farm to Market (FM) 1460, opposite La Conterra Boulevard and the La Conterra subdivision, between Inner Loop and Westinghouse Road. The plat proposed the primary entrance to be opposite the existing La Conterra Boulevard. Physical Characteristics: The subject property is a long, slender rectangle running generally east/west. Two un-named tributary streams converge on the property, with a portion of 100-year floodplain present. A tree survey has indicated 30 Heritage trees to remain. The plat was designed in conjunction with the City Urban Forester to ensure buildable areas within each residential lot that provide protection to the Heritage Trees. History The property is contiguous and in addition to the original land within the City’s extraterritorial jurisdiction envisioned to be part of the Teravista subdivision. This plat will operate as part of a larger Municipal Utility District (MUD #15) within the Extraterritorial Jurisdiction (ETJ) of the City. The property is subject to a Development Agreement (DA-2015-001), which was the third amendment to the initial Page 4 of 68 Planning Department Staff Report Teravista Section 401 Preliminary Plat Page 2 of 3 consent agreement made with the City to develop a MUD originally conceived in 2004. 2030 Plan Conformance The proposed Preliminary Plat is in general conformance with the 2030 Plan land use designation of Moderate Density Residential, which supports single family detached neighborhoods at a density ranging between 3.1 and 6 dwelling units per gross acre; 195 residential lots over 77 acres equals a density of approximately 2.5 dwelling units per gross acre. See excerpt map below, where the light brown is Moderate Density Residential, purple is Employment Center, and green is Open Space/Recreation. This project is located within Tier 2 (Intermediate Growth Area) of the current City Growth Tier Map; infrastructure facilities will be the responsibility of the developer to serve the property. Utilities As previously mentioned, this development will be part of a Municipal Utility District located within the Extraterritorial Jurisdiction of the City. The Georgetown Utility System (GUS) will be providing electric, water, and wastewater services to the subdivision via contract with the Municipal Utility District. Public utility easements are being dedicated with this plat according to the City of Georgetown standards. Transportation This plat will create an extension of a major Collector roadway (73’ right-of-way, 37’ of pavement, 35 mile per hour design speed), Blue Ridge Drive, from south to north through the western third of the subdivision. All other proposed roadways in this subdivision are classified as local roadways (50’ right-of- way, 28’ of pavement), with a design speed of 25 miles per hour. The principal entrance street, named La Conterra Boulevard, widens to a 70’ ROW at FM 1460 to accommodate an open space median lot. The subdivision connects to Teravista Section 329 via Lake Teravista Way. Greencreek Way stubs to the north to an 8-acre unplatted (but developed with a single house) property that fronts on CR 166. Sam Green Page 5 of 68 Planning Department Staff Report Teravista Section 401 Preliminary Plat Page 3 of 3 Way stubs to the south, to an approximately 20-acre tract that is envisioned for another future expansion of the Teravista MUD development. A Traffic Impact Analysis (TIA-2015-004) that looked at the traffic impacts of this subdivision was submitted and approved, and any off-site improvements or costs related to this plat will have to be completed or paid for prior to the recordation of the first Final Plat to come from this Preliminary Plat. Future Application(s) In order to proceed with development on this site, it will be necessary to obtain approval of Final Plats (one for each of the two phases) and infrastructure Construction Plans, which are administratively approved applications. Residential lots will then develop individually with Building Permits. Staff Analysis Staff Recommendation and Basis: Staff supports the Preliminary Plat as it meets all of the requirements of the City’s Unified Development Code, and the associated Development Agreement and Traffic Impact Analysis (TIA). Interdepartmental, Governmental and Agency Comments None Public Comments Public notice is not required for a preliminary plat application. There have been no inquiries about the plat. Proposed Meetings Schedule February 16, 2016 – Planning and Zoning Commission Attachments Exhibit 1 – Location Map Exhibit 2 – Proposed Preliminary Plat (12 sheets) Page 6 of 68 CITY OF GEOR G E T O W N G e o r g e t o w n E T J G e o r g e t o w n E T J Georgetown E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J Georgetown ETJ Georgeto w n ETJ G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J PP-2015-012 D A Y L I LY L O O P T E R A V I S T A X I N G B L U E R I D G E P KW Y BLUERIDGE D R W RIDGE L I N E B L V D N A T U R I T A DR L A K E T E R A V ISTAWAY B L U E W A T E R L E A F L N MIR A V AL L O O P S U M M E R A Z U R EST SACHENST LA CONT E R R A B L V D R O C K M I L L L N CLEARVIE W D R CLEARV I E W D R GRAN D E M E S A D R R A B B I T C R E E K P K WY BLUE A G A V E L N S C E N I C L A K E D R S C E N I C L A K E DR COMMERC E B L V D C R E S T E D B U T T E W A Y F M 1460 M A Y S S T DRESDEN CV LILY T U R F C V H O N E Y B I R D L N CH E R O K E E R O S E C I R SEINNER LO O P COLONYGL E N L N REUNION L N PLANTER S L N M O N T E R O S A L N WESTINGH O U S E R D HILLVUE RD S N E A D D R L O O K O U T R D G MIDNIGHT L N B L U E S P R I N GS B L V D P A R K C E N T R A L B L V D R A B B I T H I L L R D CR 1 6 6 PP-2015-012Exhibit #1 Location Map Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only 0 2,000 4,000Feet ¯ Legend SiteParcelsCity LimitsGeorgetown ETJ §¨¦35 ")1460 Tera vis t a X ing Westingho u s e R d R a b b it H I l l R d ")1460 Site City Limits Street Site ³ Page 7 of 68 Page 8 of 68 Page 9 of 68 Page 10 of 68 Page 11 of 68 Page 12 of 68 Page 13 of 68 Page 14 of 68 Page 15 of 68 Page 16 of 68 Page 17 of 68 Page 18 of 68 Page 19 of 68 City of Georgetown, Texas Planning and Zoning February 16, 2016 SUBJECT: Consideration and possible action on a Subdivision Plat Waiver, pursuant to Section 3.22 of the Unified Development Code (UDC), to Section 6.02.010.B of the UDC related to frontage on a public street and Section 6.02.040.B related to Block Length for the Highland Estates subdivision being 28.75 acres in the C. Joyner and G. B. Mayhill Surveys located along the east side of CR 262. WAV-2016-001 (Valerie Kreger, AICP, Principal Planner) ITEM SUMMARY: Background: The applicant has requested Plat Waivers to the requirement that all lots front on a public street (UDC Section 6.02.010.B) and the maximum block length limit (UDC Section 6.02.040.B) to allow for the development of a 25 lot subdivision with gated, private streets. Public Comment: As of the date of this report, no written public comments have been received. Recommended Motion: Approval of the requested Plat Waivers to UDC Sections 6.02.010.B and 6.02.040.B for the Highland Estates Preliminary Plat. FINANCIAL IMPACT: None. The applicant has paid the required fees. SUBMITTED BY: Valerie Kreger, AICP, Principal Planner, and Sofia Nelson, CNU-A, Planning Director ATTACHMENTS: Description Type Staff Report Cover Memo Location Map Exhibit Proposed Highland Estates Subdivision Backup Material Page 20 of 68 Georgetown Planning Department Staff Report Highland Estates Plat Waiver Page 1 of 3 Report Date: February 12, 2016 File No: WAV-2016-001 Project Planner: Valerie Kreger, AICP, Principal Planner Item Details Project Name: Highland Estates Location: East side of CR 262 north of Russell Park (see Exhibit 1) Legal Description: 28.75 acres in the C. Joyner and G. B. Mayhill Surveys Applicant: Norm Ashby, Wildewood Construction Development Group Property Owner: Norm Ashby, Wildewood Construction Development Group Existing Use: Undeveloped land Existing Zoning: Extraterritorial Jurisdiction (ETJ); no zoning Future Land Use: Low Density Residential Growth Tier: Tier 3 Applicant’s Request The applicant has requested Plat Waivers to the requirement that all lots front on a public street (UDC Section 6.02.010.B) and the maximum block length limit of 1320 feet (UDC Section 6.02.040.B) to allow for the development of a 25 lot residential subdivision with gated, private streets. Site Information Location: The property is located in the city’s ETJ on the east side of County Road 262 (Russell Park Road), northwest of Russell Park (Corp of Engineers), and backing up to the Estates of Westlake subdivision. Physical Characteristics: The majority of the property is fairly level with elevation rising along the northern edge and the center of the property and dropping along the southern edge. Tree coverage is moderate, with oaks and cedar scattered throughout the property, although there are 23 Heritage Trees grouped mainly along the northern and southern portions. A sensitive feature (cave) is locate in the southwestern quarter of the tract. Requested Waivers First, the applicant is requesting a waiver to the public street frontage requirement in order to develop a gated neighborhood with private streets UDC Section 6.02.010.B, General Lot Requirements, states “All development (with the exception of open space or drainage lots) shall have direct access and frontage on one of the following: 1. A public street; or 2. A public street via a public alley.” A UDC Code Interpretation was published on October 8, 2013, which, in a change from previous interpretations, allows for the construction of private streets in rural residential subdivisions, provided the streets meet the standards of UDC Section 13.04.050. At the time of interpretation, gates were not allowed, however, since that time the 2012 International Fire Code has been adopted which does not prohibit gates. However, even with these changes, the specific requirement of Section 6.02.010.B that each lot have public street frontage must be waived in order Page 21 of 68 Planning Department Staff Report Highland Estates Plat Waiver Page 2 of 3 to create the new lots in this subdivision that will not have public street frontage and accomplish the desired gated, private street neighborhood. Secondly, the applicant has requested a waiver to the maximum block length of the UDC by 127 feet (approximately 2%). UDC Section 6.02.040.B, Block Length, states “Block lengths shall not exceed 20 lots or be longer than 1,320 feet, whichever is shorter. Block lengths shall be ended only by the intersection of a public street, except where there is no public street intersection due to the presence of parks, open spaces or other similar uses with at least 100 feet of street frontage on the relevant block.” The applicant has designed a 1,447 foot long main street (Highland Springs Lane) through the subdivision without a break in the block along its south side (Block B). The applicant explains that the subdivision is serviced by a private street that accesses a public street on one end and a county road on the other end. The distance between the public streets at each end of the subdivision is greater than 1,320 feet so the block length provision of the UDC cannot be met. Due to the minimum 1-acre size requirement for on-site septic systems, only eight lots are located within Block B. The subdivision also meets the connectivity requirements of the UDC due to its limited number of lots. Staff Analysis Staff Recommendation and Basis: Staff is supportive of the requested waivers based on the following: 1. Staff finds that the requested waivers meet the Approval Criteria of Section 3.22.070: A. That the granting of the waiver will not be detrimental to the public health, safety, or welfare or injurious to other property in the area or to the City in administering this Code. The two waivers will present no detrimental effects to other properties or the City’s administration of this Code. Emergency services will maintain access through the subdivision, therefore providing emergency connectivity between the existing Estates of Westlake subdivision and CR 262. B. That the granting of the waiver would not substantially conflict with the Comprehensive Plan and the purposes of this Code. The waiver will not conflict with the Comprehensive Plan, or purposes of the Code. The lots within the subdivision will still have acceptable access to private streets meeting public standards. Additionally, emergency access will be provided between the Estates of Westlake subdivision and CR 262. The existing collector street stub that originally extended to this property is being rerouted to the south of this property, maintaining the ability for a public connection between the Estates of Westlake subdivision and CR 262 in the future. C. That the conditions that create the need for the waiver do not generally apply to other property in the vicinity. The conditions creating the need for the waiver are generated by the conflicting sections of the UDC regarding private streets, and not the actions of the applicant. Page 22 of 68 Planning Department Staff Report Highland Estates Plat Waiver Page 3 of 3 D. That application of a provision of this Code will render subdivision of the land impossible. The application of the provisions of the Code being considered for waiver would not allow for the development of a subdivision with private streets as provided for in the October 8, 2013, UDC Code Interpretation. 2. Staff recognizes the requirements for public street frontage, which may be waived per the UDC, directly conflict with the allowance of subdivisions with private streets, therefore necessitating a waiver of public street frontage to accomplish. 3. The streets will be built to public standards, emergency access and connectivity will be maintained through the subdivision, and the continuation of public access from the Estates of Westlake subdivision will be possible to the south of the Highland Estates subdivision. 4. The proposed Block B, at 1,447 feet, is only 2% greater than the maximum length allowed per the UDC and with only eight lots within the block, is much less than the 20 lot maximum. Public Comments Public notification is not required for a Subdivision Waiver application. Attachments Exhibit 1 – Location Map Exhibit 2 – Proposed Preliminary Plat (PP-2014-020) Page 23 of 68 C I T Y O F G E O R G E T O W N G e o r g eto w n E T J GeorgetownETJ WAV-2016-001 G U N N R A N C H RD WILD E R N E S S T R L MARQUESA T R L SANMARINOTRL C R 262 VENEZIACIR W I LDERN E S S C V B R A N T D R HIGHLAN D S P R I N G L N WHISPERIN G SP RIN G LN T U S C A N Y W AY W H I T N E Y W O ODS C I R P O R T O A FINOLN WAV-2016-001 Exhibit #1 Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only 0 1,000 2,000Feet ¯ Le ge ndSiteParcelsCity LimitsGeorgetown ETJ ")3405 ")262 Jim H o g g Rd ")262 ")2338 Site City Limits Street Site ³ Location Map Page 24 of 68 S1 4 ° 4 3 ' 3 9 " W 3 2 7 . 9 6 ' S0 6 ° 2 0 ' 4 8 " W 1 9 5 . 9 0 ' S77° 49' 3 7 " E 1 8 8 . 8 0 ' N06° 42' 33"E 70.41'S68° 5 7 ' 4 0 " E 2 1 0 . 0 4 ' S5 4 ° 0 5 ' 3 7 " E 1 0 0 . 0 6 ' S 2 7 ° 5 1 ' 5 6 " E 1 3 0 . 2 4 ' N66° 2 9 ' 5 9 " E 6 1 6 . 1 0 ' N 2 8 ° 4 0 ' 3 7 " W 2 2 7 . 0 1 ' N62° 2 6 ' 1 9 " E 2 9 6 . 3 0 ' C 1 N0 4 ° 3 6 ' 3 7 " E 2 8 4 . 2 8 ' C2 N89° 42' 08"W 88.86'S86° 28' 52"W 197.88' S70° 04 ' 4 2 " W 1 8 8 . 0 3 ' S83° 08' 09"W 23 2 . 4 5 ' N 1 3 ° 3 6 ' 3 1 " W 2 2 1 . 0 6 ' N 3 1 ° 2 2 ' 0 9 " W 2 7 9 . 0 8 ' S58° 3 7 ' 5 1 " W 2 7 2 . 7 7 ' L 7 L6 S26° 01' 06"W 74.05' S48° 3 5 ' 2 0 " W 2 5 8 . 3 9 ' S 3 9 ° 5 5 ' 1 6 " E 1 6 0 . 2 8 ' S 2 0 ° 2 4 ' 5 5 " E 3 4 0 . 4 5 ' S55° 5 4 ' 0 1 " W 3 3 9 . 3 1 ' S0 9 ° 4 4 ' 5 2 " W 1 8 9 . 3 1 ' S 0 4 ° 0 3 ' 2 1 " E 2 5 6 . 4 4 ' S 1 4 ° 1 6 ' 0 1 " E 2 7 4 . 9 0 ' S 0 6 ° 0 5 ' 4 9 " E 2 5 3 . 1 3 ' S0 0 ° 0 0 ' 0 0 " E 3 3 9 . 0 4 ' S88° 14' 10"W 290.50' S80° 16' 48" E 1 1 0 . 7 5 ' N 1 8 ° 0 8 ' 2 4 " W 2 6 5 . 5 2 ' N1 9 ° 5 4 ' 4 1 " E 3 8 6 . 1 4 ' N1 9 ° 5 4 ' 4 1 " E 1 7 8 . 5 3 ' S85° 50' 43"E 158.32' N0 5 ° 0 9 ' 1 0 " E 2 6 6 . 3 6 ' S86° 51' 15"E 194.32' S86° 51' 15"E 170.20' N 2 8 ° 2 3 ' 2 0 " W 3 0 5 . 6 8 ' N0 4 ° 0 9 ' 1 7 " E 1 7 3 . 9 9 ' N0 4 ° 0 9 ' 1 7 " E 1 0 9 . 1 1 ' N35 ° 3 8 ' 4 0 " E 1 8 1 . 7 0 ' N73° 42' 1 3 " E 3 1 1 . 4 0 ' S84° 55' 27"E 297.91 ' S84° 55' 27"E 271.42 ' N48 ° 1 6 ' 1 0 " E 2 3 8 . 4 2 ' N63° 3 4 ' 2 8 " E 1 3 0 . 2 9 ' C29 C5 N62° 2 0 ' 1 9 " E 76.41 ' C6 C7 C 8 N 1 3 ° 3 9 ' 3 4 " W 6 0 . 3 6 ' C 9 C10 C1 1 S 1 3 ° 3 9 ' 3 4 " E 6 0 . 3 6 ' C 1 2 S0 1 ° 4 5 ' 5 0 " E 87 . 7 4 ' C 1 3 C14 S70° 5 2 ' 2 5 " E 85.16' N2 0 ° 4 2 ' 3 7 " E 9 4 . 8 4 ' C1 6 N0 5 ° 0 4 ' 3 3 " E 1 7 0 . 0 8 ' C 1 7 C18 C19 S0 5 ° 0 4 ' 3 3 " W 1 7 0 . 0 8 ' C2 0 S2 0 ° 4 2 ' 3 7 " W 9 2 . 0 7 ' C 2 1 S70° 5 2 ' 2 5 " E 1 3 8 . 0 7 ' C 2 2 S0 4 ° 1 4 ' 4 9 " W 73 . 2 5 ' C28 N70° 5 2 ' 2 5 " W 3 2 3 . 2 6 ' N0 4 ° 1 4 ' 4 9 " E 73 . 2 5 ' N0 4 ° 0 9 ' 1 7 " E 2 3 3 . 0 7 ' C 2 5 C26 C27 42.05 ' 34.36 ' 33.52 ' 42.90 ' L=15.64' L = 8 6 . 5 0 ' L=20.69' L=5 9.5 7 ' L =3 9.85'L=31.42' L=14.46' 20 3 . 3 5 ' 13 5 . 6 8 ' 14 2 . 6 1 ' 27 . 4 7 ' 15 5 . 7 6 ' 5.92' L = 115.72' L =6 7.06' L = 3 9 . 8 6 ' L=78.90' 8.40' 119.4 8 ' 18.58' 168.43 ' 127.8 7 ' 190.51 ' 276.20 ' 145.22 ' 172.5 9 ' 37.45 ' 10 9 . 5 5 ' 86 . 3 5 ' 12 5 . 4 5 ' 15 8 . 0 0 ' 44 . 5 2 ' 3 1 1 . 6 6 ' 1.33' 2 8 . 8 0 ' 1 5 8 . 0 3 ' 0.61' 1 2 1 . 0 5 ' 1 1 8 . 2 5 ' 1 0 2 . 8 1 ' 166.55' 65.89' 74.94' 113.09' 67.66'130.22'88.86' 6.90' L = 5 5 . 1 3 ' 66 . 3 5 ' L = 1 4 5 . 3 3 ' L=22.43' L=166.10'L =1 8 7 .7 2 ' 60.0' 60.0 ' 65.86 ' 68.82 ' 35.61 ' 57.81' 39.35' 40 . 1 3 ' N O C O N S T R U C T I O N B U I L D I N G S E T B A C K E A S E M E N T NO C O N S T R U C T I O N B U I L D I N G SE T B A C K E A S E M E N T DRAINAGE EASEMENT (N 0 7 ° 4 9 ' 3 5 " E 1 9 3 . 6 5 ' ) L=91.84', R=200.00' (N 0 7 ° 4 9 ' 3 5 " E 1 9 3 . 6 5 ' ) 36.72 ' S36 ° 3 1 ' 2 0 " W 55. 0 1 ' C15 80.18' L =1 1 1 .6 4 ' N0 1 ° 4 5 ' 5 0 " W 85 . 2 3 ' 71 . 6 4 ' 10 2 . 4 9 ' L1 L3 L4 S59° 2 2 ' 5 4 " W 1 7 9 . 7 9 ' L=157.08', R=50.00' S60° 1 2 ' 5 5 " W 3 9 3 . 4 6 ' 39 . 3 4 ' 32.85' 267.2 1 ' S62° 2 0 ' 1 9 " W 76.41 ' 11 0 . 1 5 ' L 5 L2 56.05' L8 L9 L1 0 C 2 3 C 2 4 15' DRAINAGE EASEMENT 30 . 2 0 ' 15' WIDE DRAINAGE EASEMENT 12 . 5 6 ' LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 BEARING S59° 22' 54"W S31° 30' 36"W S59° 22' 54"W S87° 15' 13"W S30° 17' 22"E S58° 38' 42"W S27° 05' 10"E S78° 00' 19"E N55° 48' 05"W N19° 09' 31"E DISTANCE 24.89' 55.03' 49.57' 30.93' 20.35' 4.68' 56.43' 80.55' 38.46' 32.23' CURVE TABLE CURVE C1 C2 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 RADIUS 727.51' 1111.23' 170.00' 630.00' 25.00' 175.00' 25.00' 60.00' 25.00' 225.00' 25.00' 630.00' 25.00' 175.00' 25.00' 60.00' 25.00' 225.00' 25.00' 230.00' LENGTH 202.67' 88.19' 83.92' 252.41' 37.99' 36.33' 23.55' 301.53' 23.55' 46.71' 36.73' 165.74' 38.58' 47.75' 23.55' 301.53' 23.55' 61.40' 39.96' 301.55' DELTA 15°57'40" 4°32'50" 28°17'03" 22°57'20" 87°03'30" 11°53'43" 53°58'05" 287°56'10" 53°58'05" 11°53'43" 84°10'58" 15°04'23" 88°24'58" 15°38'04" 53°58'05" 287°56'10" 53°58'05" 15°38'04" 91°35'02" 75°07'15" CHORD BEARING S03° 31' 22"E S02° 20' 09"W N76° 28' 51"E N73° 48' 59"E N41° 45' 55"E N07° 42' 42"W N40° 38' 37"W N76° 20' 26"E S13° 19' 29"W S07° 42' 42"E S43° 51' 20"E S78° 24' 37"E N64° 55' 06"E N12° 53' 35"E N21° 54' 29"W S84° 55' 27"E S32° 03' 36"W S12° 53' 35"W S25° 04' 54"E S33° 18' 48"E CHORD LENGTH 202.01' 88.17' 83.07' 250.73' 34.44' 36.27' 22.69' 70.59' 22.69' 46.63' 33.52' 165.26' 34.86' 47.60' 22.69' 70.59' 22.69' 61.21' 35.84' 280.41' CURVE TABLE CURVE C23 C24 C25 C26 C27 C28 C29 RADIUS 215.00' 275.00' 170.00' 570.00' 230.00' 25.00' 25.00' LENGTH 129.60' 165.76' 222.89' 465.46' 120.45' 38.28' 41.01' DELTA 34°32'11" 34°32'11" 75°07'15" 46°47'15" 30°00'19" 87°44'02" 93°59'15" CHORD BEARING S13° 01' 16"E S13° 01' 16"E S33° 18' 48"E N85° 43' 57"E N77° 20' 29"E S48° 28' 38"W S42° 23' 01"E CHORD LENGTH 127.64' 163.26' 207.26' 452.64' 119.08' 34.65' 36.56' S 3 0 ° 1 7 ' 2 2 " E 5 9 . 6 8 ' N31° 22' 09"W 3.79' N58° 3 8 ' 4 2 " E 2 7 4 . 8 8 ' S26° 01' 06"W 0.61' S58° 38' 42"W 4.68' N 2 7 ° 0 5 ' 1 0 " W 5 6 . 4 3 ' S58° 3 7 ' 5 1 " W 2 7 2 . 7 7 ' S2 6 ° 0 1 ' 0 6 " W 74 . 0 5 ' APPR O X I M A T E L O C A T I O N O F 1 5 ' WATE R L I N E E A S E M E N T B A S E D O N C I T Y OF G E O R G E T O W N G I S L O C A T I O N S VOLU M E 2 1 6 8 , P A G E 4 4 DATE: JULY 2015 JOB NO.P2659.00 SHEET 1 OF 2 OWNER/AGENT UICK INC. LAND SURVEYING MAILING ADDRESS: 4500 WILLIAMS DR. SUITE 212, BOX 228, GEORGETOWN, TX 78633 OFFICE: 3305 SHELL ROAD, SUITE 100, GEORGETOWN, TX. 78628 FIRM NUMBER: 10194104 PHONE: 512-915-4950 FIELD NOTES FOR A 28.752 ACRE TRACT OF LAND: BEING A 28.752 ACRE TRACT OF LAND LOCATED IN THE C. JOYNER SURVEY, ABSTRACT NO. 820, AND THE G.B. MAYHALL SURVEY, ABSTRACT NO. 821, WILLIAMSON COUNTY, TEXAS, SAID 28.752 ACRE TRACT BEING ALL OF A CALLED 10.27 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025683, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, A PORTION OF A CALLED 17.73 ACRE TRACT RECORDED IN DOCUMENT NO. 2010023651, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, AND A PORTION OF A CALLED 17.85 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025273, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, SAID 28.752 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING AT A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" PLASTIC CAP LOCATED AT THE WEST CORNER OF LOT 10, ESTATES OF WESTLAKE, PHASE 3B, RECORDED IN CABINET EE, SLIDES 386-387, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTH CORNER OF HIGHLAND SPRINGS LANE (60 FOOT RIGHT-OF-WAY), AN ANGLE POINT IN THE SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST RIGHT-OF-WAY LINE OF HIGHLAND SPRINGS LANE, A SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 26° 01' 06" W, A DISTANCE OF 74.05' (RECORD, S26°06'16"W 73.88') TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" PLASTIC CAP LOCATED AT THE NORTH CORNER OF LOT 9, ESTATES OF WESTLAKE, PHASE 3B, THE WEST RIGHT-OF-WAY CORNER OF HIGHLAND SPRINGS LANE, AN ANGLE POINT OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST LINE OF SAID LOT 9, THE SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 58° 38' 42" W, A DISTANCE OF 4.68' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR A SOUTH CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, DEPARTING THE NORTH LINE OF SAID LOT 9, SEVERING SAID 17.73 ACRE TRACT AND SAID 17.85 ACRE TRACT THE FOLLOWING EIGHT (8) COURSES AND DISTANCES: N 27° 05' 10" W, A DISTANCE OF 56.43' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 58° 37' 51" W, A DISTANCE OF 272.77' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 31° 22' 09" W, A DISTANCE OF 279.08' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 13° 36' 31" W, A DISTANCE OF 221.06' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 83° 08' 09" W, A DISTANCE OF 232.45' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 70° 04' 42" W, A DISTANCE OF 188.03' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 86° 28' 52" W, A DISTANCE OF 197.88' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 89° 42' 08" W, A DISTANCE OF 88.86' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP LOCATED IN A THE EAST RIGHT OF WAY CURVE TO THE RIGHT OF COUNTY ROAD 262, SAID POINT BEING IN THE WEST PROPERTY LINE OF SAID 17.73 ACRE TRACT AND BEING THE SOUTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE EAST RIGHT-OF-WAY LINE OF COUNTY ROAD 262, THE WEST PROPERTY LINE OF SAID 17.73 ACRE TRACT THE FOLLOWING THREE (3) COURSES AND DISTANCES ALONG SAID CURVE TO THE RIGHT CONTAINING A RADIUS OF 1111.23', AN INTERIOR ANGLE OF 04°32'50", A CHORD BEARING OF N 02° 20' 09" E, A CHORD DISTANCE OF 88.17', AND AN ARC LENGTH OF 88.19' TO A ½" IRON ROD FOUND FOR A POINT OF TANGENCY, N 04° 36' 37" E, A DISTANCE OF 284.28' (RECORD, N04°37'37"E 284.38') TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP AT THE BEGINNING OF A CURVE TO THE LEFT; ALONG SAID CURVE TO THE LEFT CONTAINING A RADIUS OF 727.51', AN INTERIOR ANGLE OF 15°57'40", A CHORD BEARING OF N 03° 31' 22" W, A CHORD DISTANCE OF 202.01', AND AN ARC LENGTH OF 202.67' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP LOCATED AT THE SOUTHWEST CORNER OF LOT 2, CALDER SUBDIVISION, RECORDED IN CABINET BB, SLIDE 37, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTHWEST CORNER OF SAID 17.73 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, DEPARTING THE EAST RIGHT-OF-WAY LINE COUNTY ROAD 262 WITH THE COMMON SOUTHEAST LINE OF SAID LOT 2, CALDER SUBDIVISION, THE NORTHWEST LINE OF SAID 17.73 ACRE TRACT, N 62° 26' 19" E, A DISTANCE OF 296.30' (RECORD, N62°27'19"E 296.40') TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" CAP LOCATED AT THE SOUTHEAST CORNER OF SAID LOT 2, CALDER SUBDIVISION, A SOUTHWEST CORNER OF SAID 10.27 ACRE TRACT, AN INTERIOR CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHEAST LINE OF SAID LOT 2, CALDER SUBDIVISION, A SOUTHWEST LINE OF SAID 10.27 ACRE TRACT, N 28° 40' 37" W, A DISTANCE OF 227.01' [RECORD, N28°43'37"W 227.33'] TO A ½" IRON ROD WITH AN ORANGE "5784" CAP LOCATED IN THE SOUTHEAST LINE OF A CALLED 23.64 ACRE TRACT RECORDED IN DOCUMENT NO. 2010012504, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTHEAST CORNER OF SAID LOT 2, CALDER SUBDIVISION, THE NORTHWEST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE SOUTHEAST LINE OF SAID 23.64 ACRE TRACT, THE NORTHWEST LINE OF SAID 10.27 ACRE TRACT, N 66° 29' 59" E, A DISTANCE OF 616.10' [RECORD, N66°32'05"E 615.79'] TO A ½" IRON ROD LOCATED AT THE WEST CORNER OF LOT 3, ESTATES OF WESTLAKE ENCLAVE, RECORDED IN DOCUMENT NO. 2012061103, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHEAST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHEAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE COMMON LINES OF SAID 10.27 ACRE TRACT, AND LOT 3 AND LOT 4, ESTATES OF WESTLAKE ENCLAVE, THE FOLLOWING FOUR (4) COURSES AND DISTANCES: S 27° 51' 56" E, A DISTANCE OF 130.24' [RECORD, S27°59'47"E 130.16'] TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 54° 05' 37" E, A DISTANCE OF 100.06' [RECORD, S54°13'28"E 100.00'] TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" CAP FOR ANGLE; S 68° 57' 40" E, A DISTANCE OF 210.04' [RECORD, S68°57'21"E 210.07'] TO A ½" IRON ROD FOUND WITH AN ORANGE "5784" CAP FOR CORNER; N 06° 42' 33" E, A DISTANCE OF 70.41' [RECORD, N06°33'04"E 70.52'] TO A ½" IRON ROD WITH AN ORANGE "5784" CAP LOCATED AT THE SOUTHWEST CORNER OF LOT 49, ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE, RECORDED IN CABINET FF, SLIDES 367-369, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHWEST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, ALONG THE SOUTH LINE OF SAID LOT 49, ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE, AND WITH THE NORTH LINE OF SAID 10.27 ACRE TRACT, S 77° 49' 37" E, A DISTANCE OF 188.80' [RECORD, S77°49'09"E 189.02'] TO A ½" IRON ROD WITH A YELLOW "CS LTD" CAP LOCATED IN THE WEST LINE OF LOT 7, ESTATES OF WESTLAKE, PHASE 4A, RECORDED IN CABINET AA, SLIDES 380-382, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHEAST CORNER OF SAID 10.27 ACRE TRACT AND BEING A NORTHEAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE COMMON LINES OF SAID 10.27 ACRE TRACT, AND LOT 7, LOT 8, AND LOT 9, ESTATES OF WESTLAKE, PHASE 4A, THE FOLLOWING TWO (2) COURSES AND DISTANCES: S 06° 20' 48" W, A DISTANCE OF 195.90' [RECORD, S06°20'36"W 196.09'] TO A ½" IRON ROD FOUND FOR ANGLE; S 14° 43' 39" W, A DISTANCE OF 327.96' [RECORD, S14°42'48"W 327.86'] TO A ½" IRON ROD FOUND WITH A YELLOW "GRANT" CAP LOCATED AT THE NORTHWEST CORNER OF LOT 4, ESTATES OF WESTLAKE, PHASE 4B, RECORDED IN CABINET CC, SLIDES 181-183, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE SOUTHWEST CORNER OF SAID LOT 9, ESTATES OF WESTLAKE, PHASE 4A, THE SOUTHEAST CORNER OF SAID 10.27 ACRE TRACT, THE NORTHEAST CORNER OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, ALONG THE COMMON LINES OF SAID 17.73 ACRE TRACT, LOT 4, LOT 5, AND LOT 6, ESTATES OF WESTLAKE, PHASE 4B, THE FOLLOWING TWO (2) COURSES AND DISTANCES: S 20° 24' 55" E, A DISTANCE OF 340.45' (RECORD, S20°24'08"E 340.44') TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 39° 55' 16" E, A DISTANCE OF 160.28' (RECORD, S39°54'29"E 160.27') TO A ½" IRON ROD WITH A YELLOW "GRANT" CAP LOCATED AT AN ANGLE POINT OF SAID LOT 6, ESTATES OF WESTLAKE, PHASE 4B, THE NORTHEAST CORNER OF SAID LOT 10, ESTATES OF WESTLAKE, PHASE 3B, THE EAST CORNER OF SAID 17.73 ACRE TRACT, AND BEING THE EAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST LINE OF SAID LOT 10, ESTATES OF WESTLAKE, PHASE 3B, A SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 48° 35' 20" W, A DISTANCE OF 258.39' (RECORD, S48°32'51"W 258.47') TO THE POINT OF BEGINNING CONTAINING 28.752 ACES OF LAND. SITE FM 34 0 5 FM 2 3 3 8 PRELIMINARY PLAT OF HIGHLAND ESTATES LOT 2 CALDER SUBDIVISION CAB. BB, SLIDE 37, P.R. 17.095 ACRES DOC. 2016006103 O.P.R. CALLED 23.64 ACRES DOC. 2010012504 O.P.R. LOT 3 ESTATES OF WESTLAKE ENCLAVE DOC. 2012061103 P.R. LOT 4 ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE CAB. FF, SLIDES 367-369 P.R. LOT 49 LOT 7 LOT 8 LOT 9 ES T A T E S O F W E S T L A K E PH A S E 4 A CA B . A A , S L I D E S 3 8 0 - 3 8 2 P. R . LOT 5 LOT 6 E S T A T E S O F W E S T L A K E P H A S E 4 B C A B . C C , S L I D E S 1 8 1 - 1 8 3 P . R . LOT 10 ESTATES OF WESTLAKE PHASE 3B CAB. EE, SLIDES 386-387 P.R. G . B . M A Y H A L L S U R V E Y A B S T R A C T N O . 8 2 1 C . J O Y N E R S U R V E Y A B S T R A C T N O . 8 2 0 A P P R O X I M A T E S U R V E Y L I N E FOUND 1/2" IRON ROD WITH A RED "MATKIN-HOOVER ENG. & SURVEY." PLASTIC CAP FOUND 1/2" IRON ROD UNLESS SPECIFIED OTHERWISE FOUND 1/2" IRON ROD WITH AN ORANGE "5784" CAP FOUND 1/2" IRON ROD WITH A YELLOW "GRANT" CAP FOUND 1/2" IRON ROD WITH A YELLOW "CS LTD" CAP FOUND 1/2" IRON ROD WITH AN ORANGE "ATX SURVEY" CAP H I G H L A N D S P R I N G S L A N E ( 6 0 F O O T R I G H T - O F - W A Y ) P.O.B. POINT OF BEGINNING LOT 4 SET 1/2" IRON ROD WITH A BLUE "QUICK INC" PLASTIC CAP LOT 1 1.000 AC. LOT 2 1.011 AC. LOT 3 1.036 AC. LOT 4 1.018 AC. LOT 5 1.002 AC. LOT 6 1.000 AC. LOT 7 1.000 AC. LOT 8 1.005 AC. LOT 9 1.065 AC. LOT 10 1.050 AC. LOT 11 1.000 AC. LOT 12 1.003 AC. LOT 13 1.000 AC. LOT 14 1.000 AC. LOT 15 1.015 AC. LOT 16 1.017 AC. LOT 17 1.052 AC. LOT 8 1.034 AC. LOT 7 1.000 AC. LOT 6 1.000 AC.LOT 5 1.000 AC. LOT 3 1.092 AC. LOT 2 1.000 AC. LOT 1, 1.028 AC. (1.000 ACRES OUTSIDE OF RIGHT-OF-WAY DEDICATION) (0.028 ACRES WITHIN THE RIGHT-OF-WAY DEDICATION) CO U N T Y R O A D 2 6 2 (8 0 F O O T M E A S U R E D R I G H T - O F - W A Y ) HIG H L A N D G R O V E C T . (P R I V A T E R O A D , 5 0 ' R I G H T O F W A Y ) H I G H L A N D B L U F F D R . ( P R I V A T E R O A D , 5 0 ' R I G H T O F W A Y ) HIGH L A N D S P R I N G L A N E ( P R I V A T E R O A D ) (60 F O O T R I G H T - O F - W A Y ) " B L O C K A " "B L O C K A " "BLO C K A " "B L O C K A " "BLOC K A " "BLO C K A " "BLOCK B" "BLOCK B" " B L O C K B " P.O. B . SCALE: 1"=100' 0 50'100'150'200' SE N S I T I V E F E A T U R E BU F F E R Z O N E SE E N O T E , S H E E T 2 TREE TABLE POINT NUMBER SPECIES TRUNK DIA (IN)SPREAD (FT) 6009 LIVE OAK 26 30 6010 LIVE OAK 37 45 6011 LIVE OAK 39 50 6012 LIVE OAK 30 45 6013 LIVE OAK 35 45 6014 LIVE OAK 36 40 6015 LIVE OAK 38 40 6016 LIVE OAK 38 40 6017 LIVE OAK 25 40 6018 LIVE OAK 26 45 6019 LIVE OAK 30 45 6020 LIVE OAK 34 35 6021 LIVE OAK 32 40 6022 LIVE OAK 26 40 6023 LIVE OAK 30 40 6024 LIVE OAK 25 30 6025 LIVE OAK 26 40 6026 LIVE OAK 24 35 6027 LIVE OAK 25 40 6028 LIVE OAK 28 35 6029 LIVE OAK 25 40 6030 LIVE OAK 24 30 6031 LIVE OAK 29 35 6032 LIVE OAK 33 40 6033 LIVE OAK 30 40 6034 LIVE OAK 30 40 6035 LIVE OAK 28 30 TREE TABLE POINT NUMBER SPECIES TRUNK DIA (IN)SPREAD (FT) TBM 1 BENCHMARK REF: TBM1 NORTHING: 10225299.772 EASTING: 3102597.627 ELEV: 945.637 HORIZONTAL: NAD83, CENTRAL ZONE VERTICAL: NAVD88 C/O NORM ASHBY ASHBY CAPITOL INVESTMENTS P.O. BOX 1138 GEORGETOWN, TX 78627 (512) 876-9008 (512) 697-2855 FAX NORMASHBY@WILDEWOODTX.COM 10' P.U.E. 1 0 ' P . U . E . 1 0 ' P . U . E . 10' P.U.E. 10' P.U.E . 10' P. U . E . 10 ' P . U . E . 10 ' P . U . E . 6026 6025 6024 6023 6027 6028 6029 6030 6035 6034 6033 6032 6022 6021 6019 6020 6018 6017 6015 6016 6013 6014 60106009 6011 6012 LOT 1000 3.323 AC. L O T 1 0 0 0 3 . 3 2 3 A C . 15 0 ' R A D I U S S A N I T A R Y CO N T R O L E A S E M E N T 10 ' P . U . E . 10 ' P . U . E . PP-2015-014 MATKIN HOOVER ENGINEERING & SURVEYING C/O GARRETT KELLER, P.E. 8 SPENCER ROAD SUITE 100 BOERNE, TEXAS 78006 OFF: (830) 249-0600 FAX: (830) 249-0099 GKELLER@MATKINHOOVER.COM ENGINEER: FUTURE RIGHT-OF-WAY DEDICATION RECORDED IN DOCUMENT NO. (SEE DETAIL A:) 6 0 . 0 ' TEMPORARY TURN-AROUND EASEMENT DOCUMENT NO. TO BE RECORDED PRIOR TO FINAL PLAT N: 10225317.73 E: 3101217.55 N: 1022 6 2 2 7 . 0 8 E: 3101 3 8 5 . 3 2 N: 1022 6 2 9 3 . 4 6 E: 3102 2 9 6 . 4 9 N: 10224968.12 E: 3102108.76 VICINITY MAP 8 0 ' P . U . E . 80' P.U . E . 70' P.U.E.70' P.U.E. SITE PROPERTIES: LINEAR FOOT OF ROAD = 2633.73' (3.323 ACRES) NUMBER OF BLOCKS = 2 NUMBER OF LOTS = 25 PHASE ACREAGE = 28.752 (RIGHT-OF-WAY = 3.323 ACRES, RESIDENTIAL LOTS = 25.429 ACRES) REMAINING PORTION OF LOT 1 1.000 AC. DETAIL A: 1" = 100' FUTURE RIGHT-OF-WAY DEDICATION, 0.028 AC. 6 0 . 0 ' 10' W A T E R L I N E E A S E M E N T (SEE N O T E 1 . ) 10' WATERLINE EASEMENT (SEE NOTE 1.)LOT 4 1.000 AC. NOTE: 1. 10 FOOT WATERLINE EASEMENTS SHOWN ARE INTENDED TO RUN PERPENDICULAR INTO THE EXISTING WATER LINE EASEMENT. 2. THE EXISTING WATERLINE EASEMENT SHOWN IS APPROXIMATE AND BASED ON CITY OF GEORGETOWN GIS APPLICATIONS PROVIDED BY THE ENGINEER. TEMPORARY TURN-AROUND EASEMENT DOCUMENT NO. TO BE RECORDED PRIOR TO FINAL PLAT LOT 9 6031 17.09 5 A C R E S DOC. 2 0 1 6 0 0 6 1 0 3 O.P.R . SEE NOTE 31, SHEET 2 OF 2 10' P . U . E . Page 25 of 68 City of Georgetown, Texas Planning and Zoning February 16, 2016 SUBJECT: Consideration and possible action on a Preliminary Plat of 28.75 acres in the C. Joyner and G. B. Mayhill Surveys located along the east side of CR 262 to be known as Highland Estates. PP-2015- 014 (Valerie Kreger, AICP, Principal Planner) ITEM SUMMARY: Background: The applicant proposes to develop 28.75 acres of undeveloped land into 25 residential lots with gated, private street access to Russel Park Rd (CR 262) and the western stub of the existing Highland Springs Lane. The applicant is also requesting waivers to Sections 6.02.010.B and 6.02.040.B of the UDC regarding public street frontage and block length, being processed via application WAV-2016-001 concurrently to this Preliminary Plat application. Public Comment: As of the date of this report, no written public comments have been received. Recommended Motion: Approval of the Preliminary Plat for Highland Estates, subject to the approval of the companion Plat Waiver (WAV-2016-001) and the following condition: Notwithstanding all standard provisions applicable to the Highland Estates plat, prior to approval or recordation of the highland estates plat, the owners of a called 17.095 acre tract (doc. 2016006103 o.p.r.) and the 0.028 acre portion of Lot 1, Block B, shall dedicate fee simple to Williamson County a tract of land being 60 feet wide and 274.88 feet long adjacent to the remaining portion of Lot 1, Block B of the Highland Estates Subdivision and one of the following conditions must be met: 1. A collector level roadway and associated drainage improvements designed to meet the City of Georgetown standards shall be constructed and accepted by the County within said dedication. 2. Fiscal surety in accordance with the Williamson County Subdivision Regulations, Section 7.2, shall be provided to Williamson County for the construction of a collector level roadway and associated drainage improvements designed in accordance with the City of Georgetown standards within said dedication. FINANCIAL IMPACT: None. The applicant has paid the required fees. SUBMITTED BY: Valerie Kreger, AICP, Principal Planner and Sofia Nelson, CNU-A, Planning Director Page 26 of 68 ATTACHMENTS: Description Type Staff Report Cover Memo Location Map Exhibit Highland Estates Preliminary Plat Exhibit Page 27 of 68 Georgetown Planning Department Staff Report Highland Estates Preliminary Plat Page 1 of 3 Report Date: February 12, 2016 File No: PP-2015-014 Project Planner: Valerie Kreger, AICP, Principal Planner Item Details Project Name: Highland Estates Project Address: CR 262 (Russell Park Road) Location: East side of CR 262 north of Russell Park (see Exhibit 1) Total Acreage: 28.75 acres Legal Description: 28.75 acres in the C. Joyner and G. B. Mayhill Surveys Applicant: Norm Ashby, Wildewood Construction Development Group Property Owner: Norm Ashby, Wildewood Construction Development Group Proposed Lots: 25 residential lots, 1 private street lot Streets Proposed: 2,633.73 linear feet of private streets Parkland: Fees-in-lieu Heritage Trees: 23 Heritage Trees are located within this plat Existing Use: Undeveloped land Existing Zoning: Extraterritorial Jurisdiction (ETJ); no zoning Future Lane Use: Low Density Residential Growth Tier: Tier 3 Applicant’s Request The applicant proposes to develop 28.75 acres of undeveloped land into 25 1-acre residential lots with gated, private street access to Russel Park Rd (CR 262) and the western stub of the existing Highland Springs Ln. The applicant is also requesting waivers to Sections 6.02.010.B and 6.02.040.B of the UDC regarding public street frontage and block length, being processed via application WAV-2016-001 concurrently to this Preliminary Plat application. A UDC Code Interpretation was published on October 8, 2013, which, in a change from previous interpretations, allows for the construction of private streets in rural residential subdivisions, provided the streets meet the standards of UDC Section 13.04.050. At the time of interpretation, gates were not allowed, however, since that time the 2012 International Fire Code has been adopted which does not prohibit gates. Even with these changes, the specific requirement of Section 6.02.010.B that each lot have public street frontage must be waived in order to create the new lots in this subdivision. An additional waiver to exceed the 1,320 foot maximum block length of the UDC by 127 feet (approximately 2%) was also requested. The applicant has designed a 1,447 foot long main street (Highland Springs Lane) through the subdivision without a break in the block along its south side (Block B). Due to the minimum 1-acre size requirement for on-site septic systems, only eight lots are located within Block B. The private streets proposed meet all dimensional requirements for the City of Georgetown and will be built to public road standards. Additionally, a Home Owner Association (HOA) will be established and will be responsible for maintenance of the private streets. The subdivision meets the connectivity requirements of the UDC due to its limited number of lots and emergency access will be allowed through the subdivision, creating emergency connectivity between the existing Estates of Westlake subdivision and CR 262. The existing collector street stub that originally extended to this property is being rerouted to the south Page 28 of 68 Planning Department Staff Report Highland Estates Preliminary Plat Page 2 of 3 of this property, maintaining the ability for a public connection between the Estates of Westlake subdivision and CR 262 in the future. Site Information Location: The property is located in the city’s ETJ on the east side of County Road 262 (Russell Park Road), northwest of Russell Park (Corp of Engineers), and backing up to the Estates of Westlake subdivision. Physical Characteristics: The majority of the property is fairly level with elevation rising along the northern edge and the center of the property and dropping along the southern edge. Tree coverage is moderate, with oaks and cedar scattered throughout the property, although there are 23 Heritage Trees grouped mainly along the northern and southern portions. A sensitive feature (cave) is locate in the southwestern quarter of the tract. 2030 Plan Conformance The proposed plat is in conformance with the 2030 Plan land use designation of Low Density Residential. This land use category comprises single family neighborhoods that can be accommodated at a density ranging between 1.1 and 3 dwelling units per gross acre. This project is located within Tier 3 consisting of the most remote portions of the city’s ETJ, an area of land that will likely not be needed to meet the city’s growth needs for the next twenty years. Utilities Utilities will be provided by Pedernales Electric, City of Georgetown for water and on-site septic. Transportation This development proposes private, gated streets with two points of access to public streets, one being to CR 262 (Russell Park Road) and the other being to the existing Highland Springs Lane street stub in the Estates at Westlake subdivision. Direct access to CR 262 by lots backing up to this road will be prohibited. The private streets proposed meet all dimensional requirements for the City of Georgetown and will be built to public road standards. Additionally, a Home Owner Association (HOA) will be established and will be responsible for maintenance of the private streets. The existing Highland Springs Lane is a collector level roadway, which is not allowed to end into a lower level roadway. In this case, a private street is considered a lower level roadway since, by nature, it will not handle as many trips as the collector. While not included on this plat, the collector level roadway is proposed to reroute, continuing to the south of this subdivision. As this is a requirement of the UDC in order to approve this Preliminary Plat, a note has been placed on the plat and a condition attached to its requiring dedication of the right-of-way to the County and either construction or posting of fiscal prior to approval of a Final Plat for the Highland Estates subdivision. The subdivision meets the connectivity requirements of the UDC due to its limited number of lots and emergency access will be allowed through the subdivision, creating emergency connectivity between the existing Estates of Westlake subdivision and CR 262. The number of trips anticipated from this development did not trigger the requirement for a review of a Traffic Impact Analysis (TIA). Staff Recommendation Staff recommends approval of the Preliminary Plat, subject to the approval of the companion Plat Waiver application (WAV-2016-001) and the following condition: Page 29 of 68 Planning Department Staff Report Highland Estates Preliminary Plat Page 3 of 3 Notwithstanding all standard provisions applicable to the Highland Estates plat, prior to approval or recordation of the Highland Estates plat, the owners of a called 17.095 acre tract (doc. 2016006103 o.p.r.) and the 0.028 acre portion of Lot 1, Block B, shall dedicate fee simple to Williamson County a tract of land being 60 feet wide and 274.88 feet long adjacent to the remaining portion of Lot 1, Block B of the Highland Estates subdivision and one of the following conditions must be met: 1. A collector level roadway and associated drainage improvements designed to meet the City of Georgetown standards shall be constructed and accepted by the County within said dedication; or 2. Fiscal surety in accordance with the Williamson County subdivision regulations, Section 7.2, shall be provided to Williamson County for the construction of a collector level roadway and associated drainage improvements designed in accordance with the City of Georgetown standards within said dedication. Public Comments Public notice is not required for a preliminary plat application. There have been no inquiries about the plat. Attachments Exhibit 1 – Location Map Exhibit 2 – Proposed Preliminary Plat (2 sheets) Page 30 of 68 C I T Y O F G E O R G E T O W N G e o r g et o w n E T J PP -2 01 5-0 14 MARQUESA T R L G U N N R A N C H R D WIL D E R N E S S T R L BRANT D R SANMARINOTRL BUONASERA C R 2 6 2 VENEZIACIR W I L DERN E S S C V HIGHLAND S P R I N G L N T U S C A N Y W A Y W H I T N E Y W OODS C I R POR T O A F I N O LN PP-20 15-014Exhibit #1 Co ord inate Sys tem: Texas S tat e P lane/C entral Zone/NAD 83 /US FeetCartographic Data For Genera l Planning Purposes Onl y 0 1,000 2,000Fee t ¯ Le ge nd SiteParcelsCity LimitsGeorgetown ETJ ")3405 ")262 Jim H o g g Rd N L a k e w o o d s D r ")262 ")2338 Site City Lim its Str eet Si te ³ Page 31 of 68 S1 4 ° 4 3 ' 3 9 " W 3 2 7 . 9 6 ' S0 6 ° 2 0 ' 4 8 " W 1 9 5 . 9 0 ' S77° 49' 3 7 " E 1 8 8 . 8 0 ' N06° 42' 33"E 70.41'S68° 5 7 ' 4 0 " E 2 1 0 . 0 4 ' S5 4 ° 0 5 ' 3 7 " E 1 0 0 . 0 6 ' S 2 7 ° 5 1 ' 5 6 " E 1 3 0 . 2 4 ' N66° 2 9 ' 5 9 " E 6 1 6 . 1 0 ' N 2 8 ° 4 0 ' 3 7 " W 2 2 7 . 0 1 ' N62° 2 6 ' 1 9 " E 2 9 6 . 3 0 ' C 1 N0 4 ° 3 6 ' 3 7 " E 2 8 4 . 2 8 ' C2 N89° 42' 08"W 88.86'S86° 28' 52"W 197.88' S70° 04 ' 4 2 " W 1 8 8 . 0 3 ' S83° 08' 09"W 23 2 . 4 5 ' N 1 3 ° 3 6 ' 3 1 " W 2 2 1 . 0 6 ' N 3 1 ° 2 2 ' 0 9 " W 2 7 9 . 0 8 ' S58° 3 7 ' 5 1 " W 2 7 2 . 7 7 ' L 7 L6 S26° 01' 06"W 74.05' S48° 3 5 ' 2 0 " W 2 5 8 . 3 9 ' S 3 9 ° 5 5 ' 1 6 " E 1 6 0 . 2 8 ' S 2 0 ° 2 4 ' 5 5 " E 3 4 0 . 4 5 ' S55° 5 4 ' 0 1 " W 3 3 9 . 3 1 ' S0 9 ° 4 4 ' 5 2 " W 1 8 9 . 3 1 ' S 0 4 ° 0 3 ' 2 1 " E 2 5 6 . 4 4 ' S 1 4 ° 1 6 ' 0 1 " E 2 7 4 . 9 0 ' S 0 6 ° 0 5 ' 4 9 " E 2 5 3 . 1 3 ' S0 0 ° 0 0 ' 0 0 " E 3 3 9 . 0 4 ' S88° 14' 10"W 290.50' S80° 16' 48" E 1 1 0 . 7 5 ' N 1 8 ° 0 8 ' 2 4 " W 2 6 5 . 5 2 ' N1 9 ° 5 4 ' 4 1 " E 3 8 6 . 1 4 ' N1 9 ° 5 4 ' 4 1 " E 1 7 8 . 5 3 ' S85° 50' 43"E 158.32' N0 5 ° 0 9 ' 1 0 " E 2 6 6 . 3 6 ' S86° 51' 15"E 194.32' S86° 51' 15"E 170.20' N 2 8 ° 2 3 ' 2 0 " W 3 0 5 . 6 8 ' N0 4 ° 0 9 ' 1 7 " E 1 7 3 . 9 9 ' N0 4 ° 0 9 ' 1 7 " E 1 0 9 . 1 1 ' N35 ° 3 8 ' 4 0 " E 1 8 1 . 7 0 ' N73° 42' 1 3 " E 3 1 1 . 4 0 ' S84° 55' 27"E 297.91 ' S84° 55' 27"E 271.42 ' N48 ° 1 6 ' 1 0 " E 2 3 8 . 4 2 ' N63° 3 4 ' 2 8 " E 1 3 0 . 2 9 ' C29 C5 N62° 2 0 ' 1 9 " E 76.41 ' C6 C7 C 8 N 1 3 ° 3 9 ' 3 4 " W 6 0 . 3 6 ' C 9 C10 C1 1 S 1 3 ° 3 9 ' 3 4 " E 6 0 . 3 6 ' C 1 2 S0 1 ° 4 5 ' 5 0 " E 87 . 7 4 ' C 1 3 C14 S70° 5 2 ' 2 5 " E 85.16' N2 0 ° 4 2 ' 3 7 " E 9 4 . 8 4 ' C1 6 N0 5 ° 0 4 ' 3 3 " E 1 7 0 . 0 8 ' C 1 7 C18 C19 S0 5 ° 0 4 ' 3 3 " W 1 7 0 . 0 8 ' C2 0 S2 0 ° 4 2 ' 3 7 " W 9 2 . 0 7 ' C 2 1 S70° 5 2 ' 2 5 " E 1 3 8 . 0 7 ' C 2 2 S0 4 ° 1 4 ' 4 9 " W 73 . 2 5 ' C28 N70° 5 2 ' 2 5 " W 3 2 3 . 2 6 ' N0 4 ° 1 4 ' 4 9 " E 73 . 2 5 ' N0 4 ° 0 9 ' 1 7 " E 2 3 3 . 0 7 ' C 2 5 C26 C27 42.05 ' 34.36 ' 33.52 ' 42.90 ' L=15.64' L = 8 6 . 5 0 ' L=20.69' L=5 9.5 7 ' L =3 9.85'L=31.42' L=14.46' 20 3 . 3 5 ' 13 5 . 6 8 ' 14 2 . 6 1 ' 27 . 4 7 ' 15 5 . 7 6 ' 5.92' L = 115.72' L =6 7.06' L = 3 9 . 8 6 ' L=78.90' 8.40' 119.4 8 ' 18.58' 168.43 ' 127.8 7 ' 190.51 ' 276.20 ' 145.22 ' 172.5 9 ' 37.45 ' 10 9 . 5 5 ' 86 . 3 5 ' 12 5 . 4 5 ' 15 8 . 0 0 ' 44 . 5 2 ' 3 1 1 . 6 6 ' 1.33' 2 8 . 8 0 ' 1 5 8 . 0 3 ' 0.61' 1 2 1 . 0 5 ' 1 1 8 . 2 5 ' 1 0 2 . 8 1 ' 166.55' 65.89' 74.94' 113.09' 67.66'130.22'88.86' 6.90' L = 5 5 . 1 3 ' 66 . 3 5 ' L = 1 4 5 . 3 3 ' L=22.43' L=166.10'L =1 8 7 .7 2 ' 60.0' 60.0 ' 65.86 ' 68.82 ' 35.61 ' 57.81' 39.35' 40 . 1 3 ' N O C O N S T R U C T I O N B U I L D I N G S E T B A C K E A S E M E N T NO C O N S T R U C T I O N B U I L D I N G SE T B A C K E A S E M E N T DRAINAGE EASEMENT (N 0 7 ° 4 9 ' 3 5 " E 1 9 3 . 6 5 ' ) L=91.84', R=200.00' (N 0 7 ° 4 9 ' 3 5 " E 1 9 3 . 6 5 ' ) 36.72 ' S36 ° 3 1 ' 2 0 " W 55. 0 1 ' C15 80.18' L =1 1 1 .6 4 ' N0 1 ° 4 5 ' 5 0 " W 85 . 2 3 ' 71 . 6 4 ' 10 2 . 4 9 ' L1 L3 L4 S59° 2 2 ' 5 4 " W 1 7 9 . 7 9 ' L=157.08', R=50.00' S60° 1 2 ' 5 5 " W 3 9 3 . 4 6 ' 39 . 3 4 ' 32.85' 267.2 1 ' S62° 2 0 ' 1 9 " W 76.41 ' 11 0 . 1 5 ' L 5 L2 56.05' L8 L9 L1 0 C 2 3 C 2 4 15' DRAINAGE EASEMENT 30 . 2 0 ' 15' WIDE DRAINAGE EASEMENT 12 . 5 6 ' LINE TABLE LINE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 BEARING S59° 22' 54"W S31° 30' 36"W S59° 22' 54"W S87° 15' 13"W S30° 17' 22"E S58° 38' 42"W S27° 05' 10"E S78° 00' 19"E N55° 48' 05"W N19° 09' 31"E DISTANCE 24.89' 55.03' 49.57' 30.93' 20.35' 4.68' 56.43' 80.55' 38.46' 32.23' CURVE TABLE CURVE C1 C2 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 RADIUS 727.51' 1111.23' 170.00' 630.00' 25.00' 175.00' 25.00' 60.00' 25.00' 225.00' 25.00' 630.00' 25.00' 175.00' 25.00' 60.00' 25.00' 225.00' 25.00' 230.00' LENGTH 202.67' 88.19' 83.92' 252.41' 37.99' 36.33' 23.55' 301.53' 23.55' 46.71' 36.73' 165.74' 38.58' 47.75' 23.55' 301.53' 23.55' 61.40' 39.96' 301.55' DELTA 15°57'40" 4°32'50" 28°17'03" 22°57'20" 87°03'30" 11°53'43" 53°58'05" 287°56'10" 53°58'05" 11°53'43" 84°10'58" 15°04'23" 88°24'58" 15°38'04" 53°58'05" 287°56'10" 53°58'05" 15°38'04" 91°35'02" 75°07'15" CHORD BEARING S03° 31' 22"E S02° 20' 09"W N76° 28' 51"E N73° 48' 59"E N41° 45' 55"E N07° 42' 42"W N40° 38' 37"W N76° 20' 26"E S13° 19' 29"W S07° 42' 42"E S43° 51' 20"E S78° 24' 37"E N64° 55' 06"E N12° 53' 35"E N21° 54' 29"W S84° 55' 27"E S32° 03' 36"W S12° 53' 35"W S25° 04' 54"E S33° 18' 48"E CHORD LENGTH 202.01' 88.17' 83.07' 250.73' 34.44' 36.27' 22.69' 70.59' 22.69' 46.63' 33.52' 165.26' 34.86' 47.60' 22.69' 70.59' 22.69' 61.21' 35.84' 280.41' CURVE TABLE CURVE C23 C24 C25 C26 C27 C28 C29 RADIUS 215.00' 275.00' 170.00' 570.00' 230.00' 25.00' 25.00' LENGTH 129.60' 165.76' 222.89' 465.46' 120.45' 38.28' 41.01' DELTA 34°32'11" 34°32'11" 75°07'15" 46°47'15" 30°00'19" 87°44'02" 93°59'15" CHORD BEARING S13° 01' 16"E S13° 01' 16"E S33° 18' 48"E N85° 43' 57"E N77° 20' 29"E S48° 28' 38"W S42° 23' 01"E CHORD LENGTH 127.64' 163.26' 207.26' 452.64' 119.08' 34.65' 36.56' S 3 0 ° 1 7 ' 2 2 " E 5 9 . 6 8 ' N31° 22' 09"W 3.79' N58° 3 8 ' 4 2 " E 2 7 4 . 8 8 ' S26° 01' 06"W 0.61' S58° 38' 42"W 4.68' N 2 7 ° 0 5 ' 1 0 " W 5 6 . 4 3 ' S58° 3 7 ' 5 1 " W 2 7 2 . 7 7 ' S2 6 ° 0 1 ' 0 6 " W 74 . 0 5 ' APPR O X I M A T E L O C A T I O N O F 1 5 ' WATE R L I N E E A S E M E N T B A S E D O N C I T Y OF G E O R G E T O W N G I S L O C A T I O N S VOLU M E 2 1 6 8 , P A G E 4 4 DATE: JULY 2015 JOB NO.P2659.00 SHEET 1 OF 2 OWNER/AGENT UICK INC. LAND SURVEYING MAILING ADDRESS: 4500 WILLIAMS DR. SUITE 212, BOX 228, GEORGETOWN, TX 78633 OFFICE: 3305 SHELL ROAD, SUITE 100, GEORGETOWN, TX. 78628 FIRM NUMBER: 10194104 PHONE: 512-915-4950 FIELD NOTES FOR A 28.752 ACRE TRACT OF LAND: BEING A 28.752 ACRE TRACT OF LAND LOCATED IN THE C. JOYNER SURVEY, ABSTRACT NO. 820, AND THE G.B. MAYHALL SURVEY, ABSTRACT NO. 821, WILLIAMSON COUNTY, TEXAS, SAID 28.752 ACRE TRACT BEING ALL OF A CALLED 10.27 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025683, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, A PORTION OF A CALLED 17.73 ACRE TRACT RECORDED IN DOCUMENT NO. 2010023651, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, AND A PORTION OF A CALLED 17.85 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025273, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, SAID 28.752 ACRE TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING AT A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" PLASTIC CAP LOCATED AT THE WEST CORNER OF LOT 10, ESTATES OF WESTLAKE, PHASE 3B, RECORDED IN CABINET EE, SLIDES 386-387, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTH CORNER OF HIGHLAND SPRINGS LANE (60 FOOT RIGHT-OF-WAY), AN ANGLE POINT IN THE SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST RIGHT-OF-WAY LINE OF HIGHLAND SPRINGS LANE, A SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 26° 01' 06" W, A DISTANCE OF 74.05' (RECORD, S26°06'16"W 73.88') TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" PLASTIC CAP LOCATED AT THE NORTH CORNER OF LOT 9, ESTATES OF WESTLAKE, PHASE 3B, THE WEST RIGHT-OF-WAY CORNER OF HIGHLAND SPRINGS LANE, AN ANGLE POINT OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST LINE OF SAID LOT 9, THE SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 58° 38' 42" W, A DISTANCE OF 4.68' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR A SOUTH CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, DEPARTING THE NORTH LINE OF SAID LOT 9, SEVERING SAID 17.73 ACRE TRACT AND SAID 17.85 ACRE TRACT THE FOLLOWING EIGHT (8) COURSES AND DISTANCES: N 27° 05' 10" W, A DISTANCE OF 56.43' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 58° 37' 51" W, A DISTANCE OF 272.77' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 31° 22' 09" W, A DISTANCE OF 279.08' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 13° 36' 31" W, A DISTANCE OF 221.06' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 83° 08' 09" W, A DISTANCE OF 232.45' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 70° 04' 42" W, A DISTANCE OF 188.03' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 86° 28' 52" W, A DISTANCE OF 197.88' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; N 89° 42' 08" W, A DISTANCE OF 88.86' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP LOCATED IN A THE EAST RIGHT OF WAY CURVE TO THE RIGHT OF COUNTY ROAD 262, SAID POINT BEING IN THE WEST PROPERTY LINE OF SAID 17.73 ACRE TRACT AND BEING THE SOUTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE EAST RIGHT-OF-WAY LINE OF COUNTY ROAD 262, THE WEST PROPERTY LINE OF SAID 17.73 ACRE TRACT THE FOLLOWING THREE (3) COURSES AND DISTANCES ALONG SAID CURVE TO THE RIGHT CONTAINING A RADIUS OF 1111.23', AN INTERIOR ANGLE OF 04°32'50", A CHORD BEARING OF N 02° 20' 09" E, A CHORD DISTANCE OF 88.17', AND AN ARC LENGTH OF 88.19' TO A ½" IRON ROD FOUND FOR A POINT OF TANGENCY, N 04° 36' 37" E, A DISTANCE OF 284.28' (RECORD, N04°37'37"E 284.38') TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP AT THE BEGINNING OF A CURVE TO THE LEFT; ALONG SAID CURVE TO THE LEFT CONTAINING A RADIUS OF 727.51', AN INTERIOR ANGLE OF 15°57'40", A CHORD BEARING OF N 03° 31' 22" W, A CHORD DISTANCE OF 202.01', AND AN ARC LENGTH OF 202.67' TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP LOCATED AT THE SOUTHWEST CORNER OF LOT 2, CALDER SUBDIVISION, RECORDED IN CABINET BB, SLIDE 37, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTHWEST CORNER OF SAID 17.73 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, DEPARTING THE EAST RIGHT-OF-WAY LINE COUNTY ROAD 262 WITH THE COMMON SOUTHEAST LINE OF SAID LOT 2, CALDER SUBDIVISION, THE NORTHWEST LINE OF SAID 17.73 ACRE TRACT, N 62° 26' 19" E, A DISTANCE OF 296.30' (RECORD, N62°27'19"E 296.40') TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" CAP LOCATED AT THE SOUTHEAST CORNER OF SAID LOT 2, CALDER SUBDIVISION, A SOUTHWEST CORNER OF SAID 10.27 ACRE TRACT, AN INTERIOR CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHEAST LINE OF SAID LOT 2, CALDER SUBDIVISION, A SOUTHWEST LINE OF SAID 10.27 ACRE TRACT, N 28° 40' 37" W, A DISTANCE OF 227.01' [RECORD, N28°43'37"W 227.33'] TO A ½" IRON ROD WITH AN ORANGE "5784" CAP LOCATED IN THE SOUTHEAST LINE OF A CALLED 23.64 ACRE TRACT RECORDED IN DOCUMENT NO. 2010012504, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE NORTHEAST CORNER OF SAID LOT 2, CALDER SUBDIVISION, THE NORTHWEST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE SOUTHEAST LINE OF SAID 23.64 ACRE TRACT, THE NORTHWEST LINE OF SAID 10.27 ACRE TRACT, N 66° 29' 59" E, A DISTANCE OF 616.10' [RECORD, N66°32'05"E 615.79'] TO A ½" IRON ROD LOCATED AT THE WEST CORNER OF LOT 3, ESTATES OF WESTLAKE ENCLAVE, RECORDED IN DOCUMENT NO. 2012061103, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHEAST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHEAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE COMMON LINES OF SAID 10.27 ACRE TRACT, AND LOT 3 AND LOT 4, ESTATES OF WESTLAKE ENCLAVE, THE FOLLOWING FOUR (4) COURSES AND DISTANCES: S 27° 51' 56" E, A DISTANCE OF 130.24' [RECORD, S27°59'47"E 130.16'] TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 54° 05' 37" E, A DISTANCE OF 100.06' [RECORD, S54°13'28"E 100.00'] TO A ½" IRON ROD FOUND WITH AN ORANGE "ATX SURVEY" CAP FOR ANGLE; S 68° 57' 40" E, A DISTANCE OF 210.04' [RECORD, S68°57'21"E 210.07'] TO A ½" IRON ROD FOUND WITH AN ORANGE "5784" CAP FOR CORNER; N 06° 42' 33" E, A DISTANCE OF 70.41' [RECORD, N06°33'04"E 70.52'] TO A ½" IRON ROD WITH AN ORANGE "5784" CAP LOCATED AT THE SOUTHWEST CORNER OF LOT 49, ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE, RECORDED IN CABINET FF, SLIDES 367-369, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHWEST CORNER OF SAID 10.27 ACRE TRACT, AND BEING A NORTHWEST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, ALONG THE SOUTH LINE OF SAID LOT 49, ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE, AND WITH THE NORTH LINE OF SAID 10.27 ACRE TRACT, S 77° 49' 37" E, A DISTANCE OF 188.80' [RECORD, S77°49'09"E 189.02'] TO A ½" IRON ROD WITH A YELLOW "CS LTD" CAP LOCATED IN THE WEST LINE OF LOT 7, ESTATES OF WESTLAKE, PHASE 4A, RECORDED IN CABINET AA, SLIDES 380-382, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING A NORTHEAST CORNER OF SAID 10.27 ACRE TRACT AND BEING A NORTHEAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE COMMON LINES OF SAID 10.27 ACRE TRACT, AND LOT 7, LOT 8, AND LOT 9, ESTATES OF WESTLAKE, PHASE 4A, THE FOLLOWING TWO (2) COURSES AND DISTANCES: S 06° 20' 48" W, A DISTANCE OF 195.90' [RECORD, S06°20'36"W 196.09'] TO A ½" IRON ROD FOUND FOR ANGLE; S 14° 43' 39" W, A DISTANCE OF 327.96' [RECORD, S14°42'48"W 327.86'] TO A ½" IRON ROD FOUND WITH A YELLOW "GRANT" CAP LOCATED AT THE NORTHWEST CORNER OF LOT 4, ESTATES OF WESTLAKE, PHASE 4B, RECORDED IN CABINET CC, SLIDES 181-183, PLAT RECORDS, WILLIAMSON COUNTY, TEXAS, SAID POINT BEING THE SOUTHWEST CORNER OF SAID LOT 9, ESTATES OF WESTLAKE, PHASE 4A, THE SOUTHEAST CORNER OF SAID 10.27 ACRE TRACT, THE NORTHEAST CORNER OF SAID 17.73 ACRE TRACT, AND BEING AN ANGLE POINT OF THE HEREIN DESCRIBED TRACT; THENCE, ALONG THE COMMON LINES OF SAID 17.73 ACRE TRACT, LOT 4, LOT 5, AND LOT 6, ESTATES OF WESTLAKE, PHASE 4B, THE FOLLOWING TWO (2) COURSES AND DISTANCES: S 20° 24' 55" E, A DISTANCE OF 340.45' (RECORD, S20°24'08"E 340.44') TO A ½" IRON ROD FOUND WITH A RED "MATKIN HOOVER ENG. & SURVEY" PLASTIC CAP FOR ANGLE; S 39° 55' 16" E, A DISTANCE OF 160.28' (RECORD, S39°54'29"E 160.27') TO A ½" IRON ROD WITH A YELLOW "GRANT" CAP LOCATED AT AN ANGLE POINT OF SAID LOT 6, ESTATES OF WESTLAKE, PHASE 4B, THE NORTHEAST CORNER OF SAID LOT 10, ESTATES OF WESTLAKE, PHASE 3B, THE EAST CORNER OF SAID 17.73 ACRE TRACT, AND BEING THE EAST CORNER OF THE HEREIN DESCRIBED TRACT; THENCE, WITH THE NORTHWEST LINE OF SAID LOT 10, ESTATES OF WESTLAKE, PHASE 3B, A SOUTHEAST LINE OF SAID 17.73 ACRE TRACT, S 48° 35' 20" W, A DISTANCE OF 258.39' (RECORD, S48°32'51"W 258.47') TO THE POINT OF BEGINNING CONTAINING 28.752 ACES OF LAND. SITE FM 34 0 5 FM 2 3 3 8 PRELIMINARY PLAT OF HIGHLAND ESTATES LOT 2 CALDER SUBDIVISION CAB. BB, SLIDE 37, P.R. 17.095 ACRES DOC. 2016006103 O.P.R. CALLED 23.64 ACRES DOC. 2010012504 O.P.R. LOT 3 ESTATES OF WESTLAKE ENCLAVE DOC. 2012061103 P.R. LOT 4 ESTATES OF WESTLAKE PHASE 6A & 6B, SECTION ONE CAB. FF, SLIDES 367-369 P.R. LOT 49 LOT 7 LOT 8 LOT 9 ES T A T E S O F W E S T L A K E PH A S E 4 A CA B . A A , S L I D E S 3 8 0 - 3 8 2 P. R . LOT 5 LOT 6 E S T A T E S O F W E S T L A K E P H A S E 4 B C A B . C C , S L I D E S 1 8 1 - 1 8 3 P . R . LOT 10 ESTATES OF WESTLAKE PHASE 3B CAB. EE, SLIDES 386-387 P.R. G . B . M A Y H A L L S U R V E Y A B S T R A C T N O . 8 2 1 C . J O Y N E R S U R V E Y A B S T R A C T N O . 8 2 0 A P P R O X I M A T E S U R V E Y L I N E FOUND 1/2" IRON ROD WITH A RED "MATKIN-HOOVER ENG. & SURVEY." PLASTIC CAP FOUND 1/2" IRON ROD UNLESS SPECIFIED OTHERWISE FOUND 1/2" IRON ROD WITH AN ORANGE "5784" CAP FOUND 1/2" IRON ROD WITH A YELLOW "GRANT" CAP FOUND 1/2" IRON ROD WITH A YELLOW "CS LTD" CAP FOUND 1/2" IRON ROD WITH AN ORANGE "ATX SURVEY" CAP H I G H L A N D S P R I N G S L A N E ( 6 0 F O O T R I G H T - O F - W A Y ) P.O.B. POINT OF BEGINNING LOT 4 SET 1/2" IRON ROD WITH A BLUE "QUICK INC" PLASTIC CAP LOT 1 1.000 AC. LOT 2 1.011 AC. LOT 3 1.036 AC. LOT 4 1.018 AC. LOT 5 1.002 AC. LOT 6 1.000 AC. LOT 7 1.000 AC. LOT 8 1.005 AC. LOT 9 1.065 AC. LOT 10 1.050 AC. LOT 11 1.000 AC. LOT 12 1.003 AC. LOT 13 1.000 AC. LOT 14 1.000 AC. LOT 15 1.015 AC. LOT 16 1.017 AC. LOT 17 1.052 AC. LOT 8 1.034 AC. LOT 7 1.000 AC. LOT 6 1.000 AC.LOT 5 1.000 AC. LOT 3 1.092 AC. LOT 2 1.000 AC. LOT 1, 1.028 AC. (1.000 ACRES OUTSIDE OF RIGHT-OF-WAY DEDICATION) (0.028 ACRES WITHIN THE RIGHT-OF-WAY DEDICATION) CO U N T Y R O A D 2 6 2 (8 0 F O O T M E A S U R E D R I G H T - O F - W A Y ) HIG H L A N D G R O V E C T . (P R I V A T E R O A D , 5 0 ' R I G H T O F W A Y ) H I G H L A N D B L U F F D R . ( P R I V A T E R O A D , 5 0 ' R I G H T O F W A Y ) HIGH L A N D S P R I N G L A N E ( P R I V A T E R O A D ) (60 F O O T R I G H T - O F - W A Y ) " B L O C K A " "B L O C K A " "BLO C K A " "B L O C K A " "BLOC K A " "BLO C K A " "BLOCK B" "BLOCK B" " B L O C K B " P.O. B . SCALE: 1"=100' 0 50'100'150'200' SE N S I T I V E F E A T U R E BU F F E R Z O N E SE E N O T E , S H E E T 2 TREE TABLE POINT NUMBER SPECIES TRUNK DIA (IN)SPREAD (FT) 6009 LIVE OAK 26 30 6010 LIVE OAK 37 45 6011 LIVE OAK 39 50 6012 LIVE OAK 30 45 6013 LIVE OAK 35 45 6014 LIVE OAK 36 40 6015 LIVE OAK 38 40 6016 LIVE OAK 38 40 6017 LIVE OAK 25 40 6018 LIVE OAK 26 45 6019 LIVE OAK 30 45 6020 LIVE OAK 34 35 6021 LIVE OAK 32 40 6022 LIVE OAK 26 40 6023 LIVE OAK 30 40 6024 LIVE OAK 25 30 6025 LIVE OAK 26 40 6026 LIVE OAK 24 35 6027 LIVE OAK 25 40 6028 LIVE OAK 28 35 6029 LIVE OAK 25 40 6030 LIVE OAK 24 30 6031 LIVE OAK 29 35 6032 LIVE OAK 33 40 6033 LIVE OAK 30 40 6034 LIVE OAK 30 40 6035 LIVE OAK 28 30 TREE TABLE POINT NUMBER SPECIES TRUNK DIA (IN)SPREAD (FT) TBM 1 BENCHMARK REF: TBM1 NORTHING: 10225299.772 EASTING: 3102597.627 ELEV: 945.637 HORIZONTAL: NAD83, CENTRAL ZONE VERTICAL: NAVD88 C/O NORM ASHBY ASHBY CAPITOL INVESTMENTS P.O. BOX 1138 GEORGETOWN, TX 78627 (512) 876-9008 (512) 697-2855 FAX NORMASHBY@WILDEWOODTX.COM 10' P.U.E. 1 0 ' P . U . E . 1 0 ' P . U . E . 10' P.U.E. 10' P.U.E . 10' P. U . E . 10 ' P . U . E . 10 ' P . U . E . 6026 6025 6024 6023 6027 6028 6029 6030 6035 6034 6033 6032 6022 6021 6019 6020 6018 6017 6015 6016 6013 6014 60106009 6011 6012 LOT 1000 3.323 AC. L O T 1 0 0 0 3 . 3 2 3 A C . 15 0 ' R A D I U S S A N I T A R Y CO N T R O L E A S E M E N T 10 ' P . U . E . 10 ' P . U . E . PP-2015-014 MATKIN HOOVER ENGINEERING & SURVEYING C/O GARRETT KELLER, P.E. 8 SPENCER ROAD SUITE 100 BOERNE, TEXAS 78006 OFF: (830) 249-0600 FAX: (830) 249-0099 GKELLER@MATKINHOOVER.COM ENGINEER: FUTURE RIGHT-OF-WAY DEDICATION RECORDED IN DOCUMENT NO. (SEE DETAIL A:) 6 0 . 0 ' TEMPORARY TURN-AROUND EASEMENT DOCUMENT NO. TO BE RECORDED PRIOR TO FINAL PLAT N: 10225317.73 E: 3101217.55 N: 1022 6 2 2 7 . 0 8 E: 3101 3 8 5 . 3 2 N: 1022 6 2 9 3 . 4 6 E: 3102 2 9 6 . 4 9 N: 10224968.12 E: 3102108.76 VICINITY MAP 8 0 ' P . U . E . 80' P.U . E . 70' P.U.E.70' P.U.E. SITE PROPERTIES: LINEAR FOOT OF ROAD = 2633.73' (3.323 ACRES) NUMBER OF BLOCKS = 2 NUMBER OF LOTS = 25 PHASE ACREAGE = 28.752 (RIGHT-OF-WAY = 3.323 ACRES, RESIDENTIAL LOTS = 25.429 ACRES) REMAINING PORTION OF LOT 1 1.000 AC. DETAIL A: 1" = 100' FUTURE RIGHT-OF-WAY DEDICATION, 0.028 AC. 6 0 . 0 ' 10' W A T E R L I N E E A S E M E N T (SEE N O T E 1 . ) 10' WATERLINE EASEMENT (SEE NOTE 1.)LOT 4 1.000 AC. NOTE: 1. 10 FOOT WATERLINE EASEMENTS SHOWN ARE INTENDED TO RUN PERPENDICULAR INTO THE EXISTING WATER LINE EASEMENT. 2. THE EXISTING WATERLINE EASEMENT SHOWN IS APPROXIMATE AND BASED ON CITY OF GEORGETOWN GIS APPLICATIONS PROVIDED BY THE ENGINEER. TEMPORARY TURN-AROUND EASEMENT DOCUMENT NO. TO BE RECORDED PRIOR TO FINAL PLAT LOT 9 6031 17.09 5 A C R E S DOC. 2 0 1 6 0 0 6 1 0 3 O.P.R . SEE NOTE 31, SHEET 2 OF 2 10' P . U . E . Page 32 of 68 NEW RESIDENTIAL LOTS: 25 NEW RIGHT-OF-WAY DEDICATION: 0 I GARRETT D. KELLER, REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, DO HEREBY CERTIFY THAT THIS SUBDIVISION IS IN THE EDWARDS AQUIFER RECHARGE ZONE AND IS NOT ENCROACHED BY A ZONE A FLOOD AREA, AS DENOTED HEREIN, AND AS DEFINED BY FEDERAL EMERGENCY MANAGEMENT ADMINISTRATION FLOOD HAZARD BOUNDARY MAP, COMMUNITY PANEL NUMBER 48491C0275E, EFFECTIVE DATE SEPTEMBER 26, 2008, AND THAT EACH LOT CONFORMS TO THE CITY OF GEORGETOWN REGULATIONS. THE FULLY DEVELOPED, CONCENTRATED STORMWATER RUNOFF RESULTING FROM THE ONE HUNDRED (100) YEAR FREQUENCY STORM IS CONTAINED WITHIN THE DRAINAGE EASEMENTS SHOWN AND/OR PUBLIC RIGHTS-OF-WAY DEDICATED BY THIS PLAT. TO CERTIFY WHICH, WITNESS MY HAND AND SEAL AT GEORGETOWN, WILLIAMSON COUNTY, TEXAS, THIS ___ DAY OF FEBRUARY , 2016. LICENSED PROFESSIONAL ENGINEER GARRETT D. KELLER, PE NO. 111511 STATE OF TEXAS I, TRAVIS L. QUICKSALL , REGISTERED PROFESSIONAL LAND SURVEYOR IN THE STATE OF TEXAS, DO HEREBY CERTIFY THAT THIS PLAT IS TRUE AND CORRECTLY MADE FROM AN ACTUAL SURVEY MADE ON THE GROUND OF THE PROPERTY LEGALLY DESCRIBED HEREON, AND THAT THERE ARE NO APPARENT DISCREPANCIES, CONFLICTS, OVERLAPPING OF IMPROVEMENTS, VISIBLE UTILITY LINES OR ROADS IN PLACE, EXCEPT AS SHOWN ON THE ACCOMPANYING PLAT, AND THAT THE CORNER MONUMENTS SHOWN THEREON WERE PROPERLY PLACED UNDER MY SUPERVISION IN ACCORDANCE WITH THE SUBDIVISION REGULATIONS OF THE CITY OF GEORGETOWN, TEXAS. TO CERTIFY WHICH, WITNESS MY HAND AND SEAL AT GEORGETOWN , WILLIAMSON COUNTY, TEXAS, THIS ___ DAY OF FEBRUARY , 2016. REGISTERED PROFESSIONAL LAND SURVEYOR TRAVIS L. QUICKSALL, R.P.L.S. NO.6447 STATE OF TEXAS MATKIN HOOVER ENGINEERING & SURVEYING C/O GARRETT D. KELLER, P.E. 8 SPENCER ROAD SUITE 100 BOERNE, TEXAS 78006 OFF: (830) 249-0600 FAX: (830) 249-0099 GKELLER@MATKINHOOVER.COM PRELIMINARY PLAT OF HIGHLAND ESTATES OWNER/DEVELOPER:AGENT/PREPARER:DATE: NOVEMBER 2015 BEING A 28.75 ACRE TRACT OF LAND, LOCATED IN THE C. JONER SURVEY, ABSTRACT NO. 820, AND THE G.B. MAYHILL SURVEY, ABSTRACT NO. 821, WILLIAMSON COUNTY, TEXAS. SAID 28.75 ACRE TRACT BEING ALL OF A CALLED 10.27 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025683, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, A PORTION OF A CALLED 17.73 ACRE TRACT RECORDED IN DOCUMENT NO. 2010023651, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS, AND A PORTION OF A CALLED 17.85 ACRE TRACT RECORDED IN DOCUMENT NO. 2010025273, OFFICIAL PUBLIC RECORDS, WILLIAMSON COUNTY, TEXAS. NOTES: 1.UTILITY PROVIDERS FOR THIS DEVELOPMENT ARE WATER: CITY OF GEORGETOWN, WASTEWATER/SEPTIC:SEPTIC, AND ELECTRIC:P.E.C. 2.RURAL MAILBOXES SHALL BE SET THREE FEET FROM THE EDGE OF THE PAVEMENT OR BEHIND CURBS, WHEN USED. ALL MAILBOXES WITHIN COUNTY ARTERIAL RIGHT-OF-WAY SHALL MEET THE CURRENT TXDOT STANDARDS. ANY MAILBOX THAT DOES NOT MEET THIS REQUIREMENT MAY BE REMOVED BY WILLIAMSON COUNTY. 3.ALL PUBLIC UTILITY EASEMENTS ARE FOR UTILITY IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO ELECTRIC, TELEPHONE AND/OR CATV LINES AND APPURTENANCES. 4.ALL STRUCTURES/OBSTRUCTIONS ARE PROHIBITED IN DRAINAGE EASEMENTS. 5.BASIS OF BEARING: WAS ESTABLISHED USING THE NAD 83/93 HARN-TEXAS CENTRAL ZONE & NAVD 88. 6.ALL PUBLIC ROADWAYS AND EASEMENTS AS SHOWN ON THE PLAT ARE FREE OF LIENS. REQUIRED RELEASE OF LIENS SHALL BE PROVIDED TO THE COMMISSIONERS' COURT. 7.IN ORDER TO PROMOTE DRAINAGE AWAY FROM A STRUCTURE, THE SLAB ELEVATION SHOULD BE BUILT AT LEAST ONE-FOOT ABOVE THE SURROUNDING GROUND, AND THE GROUND SHOULD BE GRADED AWAY FROM THE STRUCTURE AT A SLOPE OF 1/2" PER FOOT FOR A DISTANCE OF AT LEAST 10 FEET. 8.THE LANDOWNER ASSUMES ALL RISKS ASSOCIATED WITH IMPROVEMENTS LOCATED IN THE RIGHT-OF-WAY, OR ROAD WIDENING EASEMENTS. BY PLACES ANYTHING IN THE RIGHT-OF-WAY OR ROAD WIDENING EASEMENTS, THE LAND OWNER INDEMNIFIES AND HOLDS THE CITY OF GEORGETOWN, WILLIAMSON COUNTY, THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY LIABILITY OWING TO PROPERTY DEFECTS OR NEGLIGENCE NOT ATTRIBUTED TO THEM AND ACKNOWLEDGES THAT THE IMPROVEMENTS MAY BE REMOVED BY THE CITY AND/OR COUNTY AND THAT THE OWNER OF THE IMPROVEMENTS WILL BE RESPONSIBLE FOR THE RELOCATION AND/OR REPLACEMENT OF THE IMPROVEMENTS. 9.PARKLAND DEDICATION REQUIREMENTS ARE BEING MET BY FEE-IN-LIEU. 10. ANY HERITAGE TREE AS NOTED ON THIS PLAT IS SUBJECT, IN PERPETUITY, TO THE MAINTENANCE, CARE, PRUNING AND REMOVAL REQUIREMENTS OF THE CITY OF GEORGETOWN, AND APPROVED REMOVAL DOES NOT REQUIRE MODIFICATION OF THE PLAT. 11. A 10-FOOT PUBLIC UTILITY EASEMENT IS RESERVED ALONG ALL STREET FRONTAGES WITHIN THIS PLAT. 12.THE MAXIMUM IMPERVIOUS COVERAGE PER RESIDENTIAL LOT IS 20% PERCENT. 13.THE BUILDING OF ALL STREETS, ROADS, AND OTHER PUBLIC THOROUGHFARES AND ANY BRIDGES OR CULVERTS NECESSARY TO BE CONSTRUCTED OR PLACED IS THE RESPONSIBILITY OF THE OWNERS OF THE TRACT OF LAND COVERED BY THIS PLAT IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS PRESCRIBED BY THE CITY OF GEORGETOWN AND/OR WILLIAMSON COUNTY, TEXAS. NEITHER THE CITY OF GEORGETOWN NOR WILLIAMSON COUNTY ASSUMES ANY OBLIGATION TO BUILD ANY OF THE STREETS, ROADS, OR OTHER PUBLIC THOROUGHFARES SHOWN ON THIS PLAT OR OF CONSTRUCTING ANY OF THE BRIDGES OR DRAINAGE IMPROVEMENTS IN CONNECTION THEREWITH. NEITHER THE CITY OF GEORGETOWN NOR WILLIAMSON COUNTY ASSUME ANY RESPONSIBILITY FOR DRAINAGE WAYS OR EASEMENTS IN THE SUBDIVISION, OTHER THAN THOSE DRAINING OR PROTECTING THE ROAD SYSTEM AND STREETS IN THEIR RESPECTIVE JURISDICTIONS. 14.NEITHER THE CITY OF GEORGETOWN NOR WILLIAMSON COUNTY ASSUMES ANY RESPONSIBILITY FOR THE ACCURACY OF REPRESENTATIONS BY OTHER PARTIES IN THIS PLAT. FLOODPLAIN DATA, IN PARTICULAR, MAY CHANGE DEPENDING ON SUBSEQUENT DEVELOPMENT. IT IS FURTHER UNDERSTOOD THAT THE OWNERS OF THE TRACT OF LAND COVERED BY THIS PLAT MUST INSTALL AT THEIR OWN EXPENSE ALL TRAFFIC CONTROL DEVICES AND SIGNAGE THAT MAY BE REQUIRED BEFORE THE STREETS IN THE SUBDIVISION HAVE FINALLY BEEN ACCEPTED FOR MAINTENANCE BY THE CITY AND / OR COUNTY. 15.THERE ARE NO AREAS WITHIN THE BOUNDARIES OF THIS SUBDIVISION IN THE 100-YEAR FLOODPLAIN AS DEFINED BY FIRM MAP NUMBER 48491C0275E, EFFECTIVE DATE OF 9/26/2008. 16.RIGHT-OF-WAY EASEMENTS FOR WIDENING ROADWAYS OR IMPROVING DRAINAGE SHALL BE MAINTAINED BY THE LAND OWNER UNTIL ROAD OR DRAINAGE IMPROVEMENTS ARE ACTUALLY CONSTRUCTED ON THE PROPERTY. THE CITY AND/OR COUNTY HAVE THE RIGHT AT ANY TIME TO TAKE POSSESSION OF ANY ROAD WIDENING EASEMENT FOR CONSTRUCTION, IMPROVEMENT, OR MAINTENANCE OF THE ADJACENT ROAD. 17.ON-SITE SEWAGE FACILITIES MUST BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER OR REGISTERED SANITARIAN. 18.NO CONSTRUCTION IN THE SUBDIVISION MAY BEGIN UNTIL THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY (TCEQ) HAS APPROVED THE WATER POLLUTION ABATEMENT PLAN (WPAP) IN WRITING. 19.THIS PLAT IS SUBJECT TO THE PROVISIONS OF THE CITY OF GEORGETOWN WATER CONSERVATION ORDINANCE. IN ACCORDANCE WITH THE ORDINANCE, IRRIGATION SYSTEMS INSTALLED ON RESIDENTIAL LOTS MAY NOT IRRIGATE AN AREA LARGER THAN 2.5 TIMES THE HOUSE FOUNDATION FOOTPRINT OR 10,000 SQUARE FEET, WHICHEVER IS THE SMALLER, WITH SPRAY OR ROTOR IRRIGATION HEADS. THE USE OF DRIP IRRIGATION, BUBBLERS, OR MICRO-SPRAYERS MAY BE USED TO EXPAND THE IRRIGATION COVERAGE AREA. 20.THE SUBDIVISION SUBJECT TO THIS APPLICATION IS SUBJECT TO THE WATER QUALITY REGULATIONS OF THE CITY OF GEORGETOWN. (FOR PROPERTIES OVER THE EDWARDS AQUIFER RECHARGE ZONE) 21.A GEOLOGIC ASSESSMENT, IN ACCORDANCE WITH THE CITY OF GEORGETOWN WATER QUALITY REGULATIONS, WAS COMPLETED ON JUNE 4, 2015. ANY SPRINGS AND STREAMS AS IDENTIFIED IN THE GEOLOGIC ASSESSMENT ARE SHOWN HEREIN. 22.NEITHER THE CITY OF GEORGETOWN NOR WILLIAMSON COUNTY SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE PRIVATE STREETS SHOWN HEREIN AND MAY NOT ACCEPT STREETS THAT HAVE NOT BEEN BUILT AND CONTINUOUSLY MAINTAINED TO APPLICABLE CITY AND COUNTY STANDARDS. A MANDATORY PROPERTY OR HOME OWNER'S ASSOCIATION, WHICH INCLUDES ALL PROPERTY TO BE SERVED BY THE PRIVATE STREETS, SHALL BE ESTABLISHED TO PROVIDE CONTINUOUS MAINTENANCE OF THE PRIVATE STREETS SHOWN HEREIN AND ANY OTHER APPURTENANCES, SUCH AS GATES, THAT ARE FOR COMMON USE BY THE RESIDENTS OF THE SUBDIVISION. A COPY OF THE PROPERTY OR HOME OWNER'S ASSOCIATION AGREEMENTS SHALL BE PRESENTED TO AND APPROVED BY THE CITY AT THE TIME OF FINAL PLATTING AND SHALL BE FILED OF RECORD WITH THE PLAT THEREOF. THE ASSOCIATION MAY NOT BE DISSOLVED, NOR MAY ANY PORTION OF THE ASSOCIATION DOCUMENTS PERTAINING TO THE MAINTENANCE OF THE PRIVATE STREETS BE AMENDED, WITHOUT THE WRITTEN CONSENT OF THE CITY. 23.LOT 1000 SHALL BE A PRIVATE STREET AND A PUBLIC UTILITY EASEMENT. ALL STREETS WITHIN LOT 1000 WITHIN THIS SUBDIVISION SHALL PROVIDE FOR RECIPROCAL ACCESS FOR INGRESS AND EGRESS TO ALL OTHER LOT OWNERS AND SUCCESSORS WITHIN THE SUBDIVISION. 24.A PERPETUAL PUBLIC SAFETY AND PUBLIC SERVICE EASEMENT FOR THE PURPOSE OF PROVIDING PUBLIC SAFETY SERVICES, POLICE, FIRE AND MEDICAL SERVICES, UTILITY METER READING, CODE ENFORCEMENT, BUILDING INSPECTIONS, SOLID WASTE COLLECTION, PUBLIC SCHOOL TRANSPORTATION, ANY OTHER PUBLIC SERVICES AND ENFORCING THE CITY ORDINANCES; AND GIVING THE CITY AND ITS AUTHORIZED OFFICERS AND DESIGNEES UNINHIBITED INGRESS AND EGRESS OVER, ACROSS AND THROUGH SUCH PRIVATE DRIVES, STREETS, ROADWAYS, AND RIGHTS-OF-WAY FOR THE PURPOSE OF PROVIDING PUBLIC SAFETY SERVICES, POLICE, FIRE AND MEDICAL SERVICES, AND ENFORCING AND ENFORCING THE PENAL CODE AND CITY ORDINANCES. THE HOA SHALL MAINTAIN AT ALL TIMES WITH THE CITY SECRETARY THE CURRENT GATE CODE OR KEY FOR ALL GATES REGULATING ACCESS TO AND FROM THE SUBDIVISION. 25.DRIVEWAYS FOR LOT 17 (BLOCK A) AND LOT 8 (BLOCK B) SHALL CONNECT ONLY TO HIGHLAND SPRINGS LANE AND NOT DIRECTLY TO CR 262. 26.THE SENSITIVE FEATURE BUFFER ZONE IS A NATURAL GEOLOGICAL FEATURE BUFFER ZONE (NON CONSTRUCTION/ LANDSCAPE EASEMENT). NO ALTERATION WITHIN THE NATURAL TERRAIN OR VEGETATION SHALL OCCUR WITHIN THIS EASEMENT. NO STORM WATER FLOW SHALL BE DIRECTED TOWARDS THIS EASEMENT. A PERMANENT FENCE SHALL BE PLACED AROUND THIS EASEMENT TO PREVENT DISTURBANCE OF THE NATURAL SOIL AND VEGETATION WITHIN THIS EASEMENT. THE PROPERTY OR HOME OWNERS ASSOCIATION SHALL BE RESPONSIBLE FOR MAINTENANCE OF THE PERMANENT FENCE AROUND THE BUFFER ZONE AND REMOVAL OF ANY TRASH OR DEBRIS FOUND WITHIN THE BUFFER ZONE. 27.NO HOMES OR STRUCTURES SHALL BE PLACED WITHIN THE "NO CONSTRUCTION BUILDING SETBACK EASEMENT". 28.THE INTENT OF THE FUTURE STREET RIGHT OF WAY DEDICATION AS SHOWN ON LOT 1 IS REQUIRED TO ENSURE A FUTURE RIGHT OF WAY WIDTH OF 60 FEET WHEN COMBINED WITH FUTURE STREET STUB-OUT ON ADJACENT PROPERTY. 29.ALL LOTS SHALL HAVE MANICURED LAWN WITH AN AREA EQUAL TO OR GREATER THAN 350% OF THE TOTAL IMPERVIOUS COVER PROPOSED ON THE LOT INCLUDING THE HOUSE FOUNDATION FOOTPRINT, SIDEWALKS, AND DRIVEWAYS. FOR EXAMPLE: IF THE PROPOSED IMPERVIOUS COVER = 6,500 SF X 3.50 = 22,950 SF OF REQUIRED MANICURED LAWN* *MANICURED LAWN IS DEFINED AS SOD PLACED AROUND THE RESIDENCE WITH AN IRRIGATION SYSTEM. REFER TO NOTE 19 FOR ADDITIONAL RESTRICTION ON LAWN IRRIGATION. C/O NORM ASHBY ASHBY CAPITOL INVESTMENTS P.O. BOX 1138 GEORGETOWN, TX 78627 (512) 876-9008 (512) 697-2855 FAX NORMASHBY@WILDEWOODTX.COM A PRELIMINARY PLAT FOR A SUBDIVISION TO BE KNOWN AS HIGHLAND ESTATES HAS BEEN APPROVED ACCORDING TO THE MINUTES OF THE MEETING OF THE GEORGETOWN PLANNING AND ZONING COMMISSION ON THE DAY OF ,20 . A.D. JOSH SCHRODER, CHAIRMAN DATE SCOTT RANKIN, SECRETARY DATE PP-2015-014 ENGINEERING & SURVEYING CIVIL ENGINEERS SURVEYORS LAND PLANNERS CONSTRUCTION MANAGERS CONSULTANTS P.O. BOX 54 8 SPENCER ROAD SUITE 100 BOERNE, TEXAS 78006 OFFICE: 830.249.0600 FAX:830.249.0099TEXAS REGISTERED ENGINEERING FIRM F-004512TEXAS REGISTERED SURVEYING FIRM F-10024000 NOTWITHSTANDING ALL STANDARD PROVISIONS APPLICABLE TO THE HIGHLAND ESTATES PLAT, PRIOR TO APPROVAL OR RECORDATION OF THE HIGHLAND ESTATES PLAT, THE OWNERS OF A CALLED 17.095 ACRE TRACT (DOC. 2016006103 O.P.R.) AND THE 0.028 ACRE PORTION OF LOT 1, BLOCK B, SHALL DEDICATE FEE SIMPLE TO WILLIAMSON COUNTY A TRACT OF LAND BEING 60 FEET WIDE AND 274.88 FEET LONG ADJACENT TO THE REMAINING PORTION OF LOT 1, BLOCK B OF THE HIGHLAND ESTATES SUBDIVISION AND ONE OF THE FOLLOWING CONDITIONS MUST BE MET: A.A COLLECTOR LEVEL ROADWAY AND ASSOCIATED DRAINAGE IMPROVEMENTS DESIGNED TO MEET THE CITY OF GEORGETOWN STANDARDS SHALL BE CONSTRUCTED AND ACCEPTED BY THE COUNTY WITHIN SAID DEDICATION. B.FISCAL SURETY IN ACCORDANCE WITH THE WILLIAMSON COUNTY SUBDIVISION REGULATIONS, SECTION 7.2, SHALL BE PROVIDED TO WILLIAMSON COUNTY FOR THE CONSTRUCTION OF A COLLECTOR LEVEL ROADWAY AND ASSOCIATED DRAINAGE IMPROVEMENTS DESIGNED IN ACCORDANCE WITH THE CITY OF GEORGETOWN STANDARDS WITHIN SAID DEDICATION. PROVIDED FIRE FLOW (GPM) DWELLING SIZE MINIMUM EXPOSURE DISTANCE 1,000 0 - 5,000 SQFT 31FT OR GREATER 1,000 0 - 3,600 SQFT 11 FT - 30 FT Page 33 of 68 City of Georgetown, Texas Planning and Zoning February 16, 2016 SUBJECT: Action on a request to Rezone 207.147 acres of land in the Addison Survey located at 2750 County Road 110, known as the Kasper Tract, from the Agriculture (AG) District to a Planned Unit Development (PUD) District with a base zoning of Residential Single-family (RS). REZ-2016-001 (Sofia Nelson, CNU-A, Planning Director) ITEM SUMMARY: Background: The subject property is located in the southeast quadrant of the City, near the intersection of Westinghouse Road and Rockride Lane. The Kasper PUD provides entitlements for a maximum of 775 residential units and includes a mix of single family detached residential lot sizes. The proposed PUD provides the flexibility to mix product types and sizes without defining multiple zoning boundaries within the property. The RS areas within Kasper are planned to include a mix of lot sizes including 40’, 50’ and 60’ lot widths. On February 2nd the Planning and Zoning Commission held a public hearing, received a presentation, and discussed the request. No action was taken. Public Comments: On February 2, 2016 two speakers spoke in opposition to the request. Staff Recommendation: Staff has reviewed the request, provided comments to the applicant and has worked with the applicant to prepare the PUD proposal for consideration. Within the staff report staff has prepared a table outlining each development standards that varies from the UDC. A staff recommendation on each item has been provided. Development Standard Code Requirement PUD Standard Staff Recommendation Lot size Minimum lot frontage of 45’ wide and minimum 5,500 square feet in size Minimum 40’ wide and 4,400 square feet in size. The requested residential lot total will not exceed 775 units. There shall be a minimum of 25% of the total units in each lot size (40s, 50s and 60s) and a maximum of 50% of the total units in any one lot size. Staff supports the request to allow the lot size mix requested by the applicant. Masonry Requirement N/A (currently there is not a minimum requirement for masonry on single family homes) At least 85% of the exterior surface area of all elevations visible from a public street or open space/ parkland shall consist of brick, stone or stucco. At least 85% of the exterior surface area of all elevations which are not visible from a public street or open space/ Staff supports of the proposed PUD masonry standards. Page 34 of 68 parkland shall consist of brick, stone, stucco, or cement based siding. No more than 50% of any wall shall consist of cement based siding Parking 2 per dwelling unit Every lot within Kasper shall provide a minimum of 2 parking spaces. The garage shall count as a minimum of one parking space as long as the garage is a minimum of 20 feet in depth, and has two spaces if the garage is more than 400 square feet. The driveway shall count as a minimum of one parking space as long as the driveway is a minimum of 20 feet deep, measured from the right of way line, so as to avoid an obstruction to the sidewalk within the right of way. Staff supports the proposed PUD parking standards. Driveways Residential- Local Street On local streets, no driveway is permitted closer to a corner than 50 feet On local streets, no driveway is permitted closer to a corner than 40’ for lots 50’ and narrower. Staff is neutral on the request for driveway spacing on for lots 50’ and narrower. The request to decrease the spacing appears to be driven by the desire to allow smaller lots. Residential- Collector Driveway access to single-family or two-family dwelling units is permitted when spaced 125 feet apart measured from center to center. Driveway access to Single Family dwelling units is permitted when spaced 50 feet apart measured center to center. Driveways shall be allowed along Residential or Major Collectors provided parking is limited to one side and the traffic speed limit along the Collector with proposed driveways shall not exceed 30 miles per hour. Staff is not supportive of the current request and is recommending an alternative recommendation. Since the last meeting staff has reviewed the requested variance, variances from this standard granted in the past, and the overall intent of a residential collector. A residential collector serves as primary access between a residential subdivision and the arterial system. It distributes and/or collects traffic from the local roads in the residential neighborhood and channels it into an arterial roadway. The driveway spacing along residential collector roadways has specifically been spaced further apart to reduce the number of traffic conflicts on a roadway specifically designed to move traffic into and out of neighborhoods. Page 35 of 68 Design alternatives that often allow for smaller lots fronting on a neighborhood collector roadway include slip roads and alley loaded products that take driveway access from the alley. Staff is recommending the following language: Up to 10 residential lots shall be allowed to face onto a residential collector street with a driveway spacing of 60 feet measured from the center of the driveway. All other driveways must meet the minimum spacing requirement outlined in the UDC. No driveway access to single-family or two-family dwelling units is permitted. On collector streets, no driveway is permitted closer to a corner than 125 feet On collector streets no driveway is permitted closer to a corner than 50 feet. Staff is neutral on the request for driveway spacing from a corner. Impervious Cover 45% of the whole site Impervious cover shall be calculated over the entire Kasper subdivision gross site area, excluding the Kenney Fort Blvd. right of way. Individual lots within Kasper may contain up to 60% impervious cover as long as the entire subdivision remains at 50% or less of the gross site area. Staff is neutral on the request for increased impervious cover. Parkland/Trails/Open Space The acreage to be contributed for any residential subdivision shall be pro-rated in an amount equal to one acre for each 50 new dwelling units projected to occupy any developing parcel. Based on 775 units a minimum land dedication of 15.5 acres is required for this subdivision. The Kasper PUD illustrates approximately 22.5 acres of public parkland/open space; a mix of greenbelts, open space, trail corridors, parks and water quality amenity lakes. The Kasper community will include a private amenity center within the first phase and land dedication that will be built as part of the second phase of the project. The amenity center will contain a resident’s only swimming pool and pool building, as well as open public recreation facilities such as a public parking lot, playground, trail Staff recommends support of the established parkland/trails/ and open space. Page 36 of 68 Section 3.06 of the Unified Development Code (UDC) establishes zoning change approval criteria, the Planning and Zoning Commission and City Council shall consider when reviewing a request for a Planned Unit Development District (PUD). The criteria and evaluation of each criteria statement has been provided in the staff report. Due to the number of approval criteria statements that staff has identified as neutral or inconsistent , five of 11 criteria statements have been evaluated as neutral and 2 of 11 criteria statements have been evaluated as inconsistent, staff does not believe a full staff recommendation of approval is appropriate. However, staff does recognize the improvements in residential material standards and parkland dedication that are gained from this PUD proposal. Should the commission recommend approval of the request staff is recommending the following conditions be added: The applicant shall at a minimum reserve 115 feet of ROW and improve one-half of the ultimate minor arterial roadway section within the boundary of Kasper. Additional improvements may be access, and an open play area. Roadway Dedication and Improvement A traffic impact analysis shall be required with any application for a subdivision or plat approval, Site Plan approval, PUD, or other procedure for which the proposed development generates traffic in excess of 2,000 average daily trips. The property owner shall dedicate and improve all required rights- of-way for internal roadways and adjacent thoroughfares. Adjacent thoroughfares include thoroughfares abutting the proposed subdivision, whether located within the boundaries of the subdivision or within public rights-of-way. A traffic impact analysis will be delayed to the subdivision phase of development. Right of way will be reserved for a 115 foot, minor arterial roadway corridor for the extension of Kenny Fort Blvd. through the project, as illustrated on Exhibit C. Kenny Fort Blvd. is a regional arterial that will provide a major circulation route for the eastern edges of Georgetown and Round Rock. To assist the municipalities and Williamson County in implementing this regional north/south roadway corridor, the Kasper development will dedicate the entire right of way for the arterial to be completed as a capital improvement project. The Kasper development will construct one half of the ultimate arterial roadway section, or construct the entire roadway as a Major Collector, within the boundary of Kasper. A Major Collector classification would accommodate all of the Kasper development traffic, as well as serve a significant amount of additional traffic that could be generated by future development in the immediate area. The City shall coordinate with the developer to determine which construction option is desired within the arterial roadway right of way. Staff is not supportive of the language as proposed by the applicant. A full TIA has not been conducted on this project. The applicant has requested a TIA be postponed until the first phase of subdivision platting. Staff is recommending the following: The applicant shall at a minimum reserve 115 feet of ROW and improve one-half of the ultimate minor arterial roadway section within the boundary of Kasper. Additional improvements may be required as a result of the City’s review of a traffic impact analysis for the subdivision including contribution to construction of the remaining one-half of the minor arterial roadway section. Page 37 of 68 required as a result of the City’s review of a traffic impact analysis for the subdivision including contribution to construction of the remaining one-half of the minor arterial roadway section. Specific wording to be added to the PUD has been included in the PUD development standards. Driveway spacing requirements along residential collector roadways shall be limited to the following: Up to 10 residential lots shall be allowed to face onto a residential collector street with a driveway spacing of 60 feet measured from the center of the driveway. All other driveways must meet the minimum spacing requirement outlined in the UDC. No driveway access to single-family or two-family dwelling units is permitted on a major collector. FINANCIAL IMPACT: n/a SUBMITTED BY: Sofia Nelson, CNU-A, Planning Director ATTACHMENTS: Description Type staff report Backup Material Kasper PUD- contains staff and applicant comments Backup Material Location Map Backup Material Future Land USe Backup Material Zoning Map Backup Material Aerial Map Backup Material Page 38 of 68 Georgetown Planning Department Staff Report Kasper Development – REZ-2016-001 Page 1 of 10 Report Date: February 11, 2016 File No.: REZ-2016-001 Project Planner: Sofia Nelson, CNU-A, Planning Director Item Details Project Name: Kasper Development Project Address: 2750 Rockride Lane Location: Generally located at the northwest corner of Westinghouse Road and Rockride Lane. Total Acreage: 207.10 acres Applicant: Mark Baker, SEC Planning Property Owner: Kasper Family Limited Partnership Existing Use: Undeveloped Property Existing Zoning: Unzoned- the property is currently working through the annexation process. Proposed Zoning: Planned Unit Development Overlay District (PUD) with a base district of RS Future Land Use: Low Density Residential Overview of Applicant’s Request The subject property is located in the southeast quadrant of the City, near the intersection of Westinghouse Road and Rockride Lane. The Kasper PUD provides entitlements for a maximum of 775 residential units and includes a mix of single family detached residential lot sizes. The proposed PUD provides the flexibility to mix product types and sizes without defining multiple zoning boundaries within the property. The RS areas within Kasper are planned to include a mix of lot sizes including 40’, 50’ and 60’ lot widths. This rezoning request is being processed concurrently with the following applications: • A request for a Municipal Utility District (MUD)- reviewed and approved by the City Council • A request for annexation- reviewed and approved by City Council. Site Information Physical Characteristics: The land is characterized by gently rolling terrain with grassland pastures. The only existing trees occur around the homestead site and the existing pond located in the northwest corner of the property. Page 39 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 2 of 10 Surrounding Properties: The subject property is located on the south eastern boundary of the city limits. The property owner has reqeuested annexation into the City. The zoning request and the 2nd reading of the annexation request will line up for review by the City Council at the same time. The surrounding zoning and land uses are as follows: Utilities: Water is provided by Jonah Water, wastewater by the City of Georgetown, and electric by Oncor Electric. As part of the MUD request a utility agreement will be reviewed by the City Council. The utility agreement will outline the major wastewater infrastructure to be provided and the phasing associated with the installment of the infrastructure. Transportation: The subject property has frontage on Westinghouse Road and Rockride Lane. The overall transportation plan (OTP) identifies a minor arterial roadway dividing the subject tract into two separate parts. The Unified Development Code (UDC) requires full dedication and construction of thoroughfares adjacent and/or internal to a property. The applicant is seeking to reduce this requirement (see below for further details). The overall connectivity, block structure, road classification and design will be required to meet all UDC development standards. Master Plan Guidance 2030 Comprehensive Plan: This property is designated as Low Density Residential on the 2030 Plan-Future Land Use Map. This category includes the city’s predominantly single-family neighborhoods that can be accommodated at a density between 1.1 and 3 dwelling units per gross acre. In order to stage contiguous, compact, and incremental growth of the city over the next two decades, the 2030 Comprehensive Plan establishes a tiered growth framework. The subject property is located in the Tier 2 Growth area. The Tier 2 lies outside the city limits, but within the City’s Extraterritorial Jurisdiction (ETJ). This area likely will be needed to serve the city’s growth needs over the next 10-20 years. Location Zoning Future Land Use Existing Use North Agriculture (AG) Mixed Use/ Employment Center Undeveloped South Outside of the city limits Low Density Residential Westinghouse Road East Outside of the city limits Low Density Residential Rockride Lane West Agriculture (AG) Medium Density Residential Undeveloped Page 40 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 3 of 10 Zoning Districts Residential Single-Family District (RS). The Residential Single-family District (RS) is intended for areas of medium density with a minimum lot size of 5,500 square feet. The RS District contains standards for development that maintain single-family neighborhood characteristics. The District may be located within proximity of neighborhood-friendly commercial and public services and protected from incompatible uses. Planned Unit Development District (PUD A PUD is designed to be used in conjunction with a designated base zoning district. An application for PUD zoning shall specify the base district(s) and the uses proposed. If no base zoning exists, the base zoning shall be that zoning designation that is most similar to or compatible with the uses proposed for the PUD. Any uses not permitted in the base district shall be specifically identified. The standards and requirements of the specified base district shall apply unless specifically superseded by the standards and requirements of the PUD Development Plan. Page 41 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 4 of 10 Staff Analysis Below is a breakdown of the requested PUD. Development Standard Code Requirement PUD Standard Staff Recommendation Lot size Minimum lot frontage of 45’ wide and minimum 5,500 square feet in size Minimum 40’ wide and 4,400 square feet in size. The requested residential lot total will not exceed 775 units. There shall be a minimum of 25% of the total units in each lot size (40s, 50s and 60s) and a maximum of 50% of the total units in any one lot size. Staff supports the request to allow the lot size mix requested by the applicant. Masonry Requirement N/A (currently there is not a minimum requirement for masonry on single family homes) At least 85% of the exterior surface area of all elevations visible from a public street or open space/ parkland shall consist of brick, stone or stucco. At least 85% of the exterior surface area of all elevations which are not visible from a public street or open space/ parkland shall consist of brick, stone, stucco, or cement based siding. No more than 50% of any wall shall consist of cement based siding Staff supports of the proposed PUD masonry standards. Parking 2 per dwelling unit Every lot within Kasper shall provide a minimum of 2 parking spaces. The garage shall count as a minimum of one parking space as long as the garage is a minimum of 20 feet in depth, and has two spaces if the garage is more than 400 square feet. The driveway shall count as a minimum of one parking space as long as the driveway is a minimum of 20 feet deep, measured from the right of way line, so as to avoid an obstruction to the sidewalk within the right of way. Staff supports the proposed PUD parking standards. Page 42 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 5 of 10 Driveways Residential- Local Street On local streets, no driveway is permitted closer to a corner than 50 feet On local streets, no driveway is permitted closer to a corner than 40’ for lots 50’ and narrower. Staff is neutral on the request for driveway spacing on for lots 50’ and narrower. The request to decrease the spacing appears to be driven by the desire to allow smaller lots. Residential- Collector Driveway access to single-family or two-family dwelling units is permitted when spaced 125 feet apart measured from center to center. Driveway access to Single Family dwelling units is permitted when spaced 50 feet apart measured center to center. Driveways shall be allowed along Residential or Major Collectors provided parking is limited to one side and the traffic speed limit along the Collector with proposed driveways shall not exceed 30 miles per hour. Staff is not supportive of the current request and is recommending an alternative recommendation. Since the last meeting staff has reviewed the requested variance, variances from this standard granted in the past, and the overall intent of a residential collector. A residential collector serves as primary access between a residential subdivision and the arterial system. It distributes and/or collects traffic from the local roads in the residential neighborhood and channels it into an arterial roadway. The driveway spacing along residential collector roadways has specifically been spaced further apart to reduce the number of traffic conflicts on a roadway specifically designed to move traffic into and out of neighborhoods. Design alternatives that often allow for smaller lots fronting on a neighborhood collector roadway include slip roads and alley loaded products that take driveway access from the alley. Staff is recommending the following language: Up to 10 residential lots shall be allowed to face onto a residential collector street with a driveway spacing of 60 feet measured from the center of the driveway. All other driveways must meet the minimum spacing requirement outlined in the UDC. No driveway access to single- family or two-family dwelling units is permitted on a major collector. Page 43 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 6 of 10 On collector streets, no driveway is permitted closer to a corner than 125 feet On collector streets no driveway is permitted closer to a corner than 50 feet. Staff is neutral on the request for driveway spacing from a corner. Impervious Cover 45% of the whole site Impervious cover shall be calculated over the entire Kasper subdivision gross site area, excluding the Kenney Fort Blvd. right of way. Individual lots within Kasper may contain up to 60% impervious cover as long as the entire subdivision remains at 50% or less of the gross site area. Staff is neutral on the request for increased impervious cover. Parkland/Trails/ Open Space The acreage to be contributed for any residential subdivision shall be pro-rated in an amount equal to one acre for each 50 new dwelling units projected to occupy any developing parcel. Based on 775 units a minimum land dedication of 15.5 acres is required for this subdivision. The Kasper PUD illustrates approximately 22.5 acres of public parkland/open space; a mix of greenbelts, open space, trail corridors, parks and water quality amenity lakes. The Kasper community will include a private amenity center within the first phase and land dedication that will be built as part of the second phase of the project. The amenity center will contain a resident’s only swimming pool and pool building, as well as open public recreation facilities such as a public parking lot, playground, trail access, and an open play area. Staff recommends support of the established parkland/trails/ and open space. Roadway Dedication and Improvement A traffic impact analysis shall be required with any application for a subdivision or plat approval, Site Plan approval, PUD, or other procedure for which the proposed development generates traffic in excess of 2,000 A traffic impact analysis will be delayed to the subdivision phase of development. Right of way will be reserved for a 115 foot, minor arterial roadway corridor for the extension of Kenney Fort Blvd. through the project, as illustrated on Exhibit C. Kenney Fort Blvd. is a regional arterial that will provide a major circulation route for the eastern edges of Georgetown and Round Rock. To assist the municipalities and Williamson County in implementing this Staff is not supportive of the language as proposed by the applicant. A full TIA has not been conducted on this project. The applicant has requested a TIA be postponed until the first phase of subdivision platting. Staff is recommending the following: The applicant shall at a minimum reserve 115 feet of ROW and improve one-half of the ultimate minor arterial roadway section within the boundary of Kasper. Page 44 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 7 of 10 average daily trips. The property owner shall dedicate and improve all required rights-of- way for internal roadways and adjacent thoroughfares. Adjacent thoroughfares include thoroughfares abutting the proposed subdivision, whether located within the boundaries of the subdivision or within public rights-of-way. regional north/south roadway corridor, the Kasper development will dedicate the entire right of way for the arterial to be completed as a capital improvement project. The Kasper development will construct one half of the ultimate arterial roadway section, or construct the entire roadway as a Major Collector, within the boundary of Kasper. A Major Collector classification would accommodate all of the Kasper development traffic, as well as serve a significant amount of additional traffic that could be generated by future development in the immediate area. The City shall coordinate with the developer to determine which construction option is desired within the arterial roadway right of way. Additional improvements may be required as a result of the City’s review of a traffic impact analysis for the subdivision including contribution to construction of the remaining one-half of the minor arterial roadway section. Evaluation of the Request: Section 3.06 of the Unified Development Code (UDC) establishes the below zoning change approval criteria, the Planning and Zoning Commission and City Council shall consider when reviewing a request for a Planned Unit Development District (PUD). Staff’s evaluation of each approval criteria is identified below in italics. Rezoning Criteria 1. The application is complete and the information contained within the application is sufficient and correct enough to allow adequate review and final action; It appears that the PUD application is not consistent with the above criteria statement. The PUD application is complete with the exception of the required traffic impact analysis. Section 12.05 of the UDC requires any application for a subdivision or plat approval, Site Plan approval, PUD, or other procedure for which the proposed development generates traffic in excess of 2,000 average daily trips to prepare a Traffic Impact Analysis. At full build out it is expected the development will generate an estimated 7,416 trips per day. 2. The zoning change is consistent with the Comprehensive Plan; It appears that the PUD application is both consistent and inconsistent with the above criteria statement. The PUD application is generally consistent with the future land use Page 45 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 8 of 10 component of the comprehensive master plan. The PUD application is inconsistent with the overall transportation plan. The applicant has requested a reduced construction requirement for the extension of the minor arterial roadway that transverses through the subject property. 3. The zoning change promotes the health, safety or general welfare of the City and the safe orderly, and healthful development of the City; It appears the PUD application is neutral in meeting this criteria statement. The proposed development is a greenfield subdivision that is located in a sector of the community that is largely undeveloped. It does not appear the proposed development promotes the incremental and orderly development of the community. However, it is important to note that it does not appear that development will negatively affect the health, safety, and general welfare of the community. 4. The zoning change is compatible with the present zoning and conforming uses of nearby property and with the character of the neighborhood; and It appears that the PUD application is neutral in meeting this criteria statement. The subject property is located in a largely undeveloped area of the community. Single family growth in the southeast quadrant of the city is increasing as wastewater infrastructure is extended. The character of the surrounding properties remains rural. To the north and west the subject properties are zoned Agriculture. To the south and east the subject properties are located outside the city limits. 5. The property to be rezoned is suitable for uses permitted by the district that would be applied by the proposed amendment. It appears the PUD application is consistent with the above criteria statement. The property to be rezoned appears to be suitable for a single family residential development and is consistent with the future land use designation for the property. PUD criteria. 1. A variety of housing types, employment opportunities, or commercial services to achieve a balanced community; The proposed PUD is inconsistent with the goal of providing a variety of housing types, employment opportunities or commercial services. The proposed development is exclusively a single family development with 3 single family lot sizes. Commercial services have not been proposed as part of this PUD request. 2. An orderly and creative arrangement of all land uses with respect to each other and to the entire community; It appears that the proposed PUD is neutral with respect to meeting this criteria statement. The proposed development is a conventional single family development. The developer is proposing a maximum of 775 units and approximately 22 acres of open Page 46 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 9 of 10 space. The arrangement of the subdivision appears to be laid out in a predictable manner. 3. A planned and integrated comprehensive transportation system providing for a separation of pedestrian and vehicular traffic, to include facilities such as roadways, bicycle ways, and pedestrian walkways; It appears that the proposed PUD is consistent with this criteria statement. 5,500 linear feet of 8’ wide concrete sidewalk will be incorporated into a centralized open space greenbelt and will connect parks and neighborhoods. Additionally, 4,200 linear feet of 8’ wide, concrete bike and walking sidewalk will be located along the south and west side of Rockride Lane/Kenney Fort Blvd. 4. The provisions of cultural or recreational facilities for all segments of the community; It appears the proposed PUD is consistent this criteria statement. The Kasper PUD Concept Plan illustrates approximately 22.5 acres of public parkland/open space; a mix of greenbelts, open space, trail corridors, parks and water quality amenity lakes. Private and public open space has been provided for within the proposed subdivision. 5. The location of general building envelopes to take maximum advantage of the natural and manmade environment; and It appears that the proposed development is neutral with respect to meeting this criteria statement. The applicant has chosen to proceed with a “bubble” concept plan. The plan outlines 12 parcels or development areas, major roadways, and parkland. Exact lot locations and building envelops have not been specified. 6. The staging of development in a manner which can be accommodated by the timely provision of public utilities, facilities, and services. It appears that the proposed development is neutral with respect to meeting this criteria statement. A phasing plan has not been provided with this PUD application. A phasing plan will be required as part of the preliminary plat stage of the subdivision process. Staff Recommendation: Staff has reviewed the request, provided comments to the applicant and has worked with the applicant to prepare the PUD proposal for consideration. Due to the number of rezoning and PUD approval criteria that staff has identified as neutral and inconsistent , five of 11 criteria statements have been evaluated as neutral and 2 of 11 criteria statements have been evaluated as inconsistent, staff does not believe a full staff recommendation of approval is appropriate. However, it is important to recognize the improvements in residential material standards and parkland dedication that are gained from this application. Should the commission recommend approval of the request staff is recommending the following conditions be added: • The applicant shall at a minimum reserve 115 feet of ROW and improve one-half of the ultimate minor arterial roadway section within the boundary of Kasper. Additional Page 47 of 68 Planning Department Staff Report Kasper Development – REZ-2016-001 Page 10 of 10 improvements may be required as a result of the City’s review of a traffic impact analysis for the subdivision including contribution to construction of the remaining one-half of the minor arterial roadway section. • Driveway spacing requirements along residential collector roadways shall be limited to the following: Up to 10 residential lots shall be allowed to face onto a residential collector street with a driveway spacing of 60 feet measured from the center of the driveway. All other driveways must meet the minimum spacing requirement outlined in the UDC. No driveway access to single-family or two- family dwelling units is permitted. Public Comments Two speakers spoke in opposition to the request during the public hearing held on 2/2/16. Meetings Schedule February 2nd – Planning and Zoning Commission- presentation and public hearing February 16th – Planning and Zoning Commission- presentation and recommendation to City Council February 23rd – City Council 1st Reading (pending) March 8th – City Council 2nd Reading (pending) Attachments Exhibit 1 – Location Map Exhibit 2 – Future Land Use Map Exhibit 3 – Zoning Map Exhibit 4 – Aerial Map Page 48 of 68 KASPER City of Georgetown, Texas PUD Planned Unit Development December 30, 2015 Revised January 27, 2016 Revised February 10, 2016 Applicant: Sentinel Land Company, LLC 4910 Campus Drive Newport Beach, CA Prepared by: SEC Planning 4201 W. Parmer Lane Building A, Suite 220 Austin, Tx 78727 Page 49 of 68 Kasper - Planned Unit Development Page 2 of 16 Exhibit A Kasper Planned Unit Development A. Purpose and Intent The Kasper PUD is composed of 207.147 acres, as described in Exhibit B (Field Notes). The development of this property is planned as a high quality, residential community with multiple residential opportunities in a variety of lot sizes and configurations. The contents of this PUD further explain and illustrate the overall appearance and function desired for this community. A Concept Plan has been attached to this PUD, Exhibit C, to illustrate the design intent for the property. The Concept Plan is intended to serve as a guide to illustrate the general community vision and design concepts and is not intended to serve as a final document. . B. Applicability and Base Zoning All aspects regarding the development of this PUD shall comply with the version of the Georgetown Unified Development Code (UDC) in effect at the date of PUD approval, except as established in this PUD exhibit, titled Exhibit A. For the purpose of complying with the UDC requirement of selecting a base zoning district, the following base district has been selected for the residential areas: RS – Residential Single Family This PUD allows the definition of final lot boundaries during the platting process. All neighborhoods within the PUD will comply with the modified development standards of this PUD. In the case that this PUD does not address a specific City requirement, the Georgetown Unified Development Code shall apply. In the event of a conflict between this PUD and the base zoning district, this PUD shall control. C. Concept Plan Exhibit C attached is a conceptual development plan intended to visually convey the design intent for the Kasper community. The design of the community is not final, and is subject to refinement during the platting and site planning stages. This PUD zoning document does not constitute plat or site plan approval of the attached plan. The residential component of the project is comprised of a mix of various single family detached products. Additionally, Kasper will include a cohesive network of open spaces, including parks, greenbelts, water quality areas, trails, and a resident’s amenity center. Commented [SN1]: Since a lot layout is no longer included I do not think the concept plan depicts the mix as indicated in this statement. Commented [MB2R1]: Okay Page 50 of 68 Kasper - Planned Unit Development Page 3 of 16 D. Allowable / Prohibited Uses The following uses within the Kasper PUD shall comply with the list of allowed and prohibited uses defined in the Georgetown UDC Chapter 5 Zoning Use Regulations. E. Lot Design Standards Residential Areas: Kasper will include a variety of detached residential product types and sizes. The residential areas shall be developed according to the following regulations:  50’and wider lot width – Develop under Georgetown UDC regulations for RS  Zero Lot line – Develop under Georgetown UDC regulations for RS, Section C.3  Lots smaller than 50’ in width will develop under regulations included in this PUD. The following unit count parameters and design standards have been established: Maximum Residential Units The requested residential total will not exceed 775 units. There shall be a minimum of 25% of the total units in each lot size (40s, 50s and 60s) and a maximum of 50% of the total units in any one lot size. The preliminary plat and any subsequent amendments to the plat shall contain a lot mix table outlining the percentage of each lot size. Masonry Requirements: At least 85% of the exterior surface area of all elevations visible from a public street or open space/ parkland shall consist of brick, stone or stucco. At least 85% of the exterior surface area of all elevations which are not visible from a public street or open space/ parkland shall consist of brick, stone, stucco, or cement based siding. No more than 50% of any wall shall consist of cement based siding. Parking Requirement Every lot within Kasper shall provide a minimum of 2 parking spaces. The garage shall count as a minimum of one parking space as long as the garage is a minimum of 20 feet in depth, and as two spaces if the garage is more than 400 square feet. The driveway shall count as a minimum of one parking space as long as the driveway is a minimum of 20 feet deep, measured from the right of way line, so as to avoid an obstruction to the sidewalk within the right of way. Driveways Commented [SN3]: Will these minimums and maximums be per subdivision plat? If not, do you have any suggestions on how this will be tracked. Commented [MB4R3]: See note about table required on preliminary plan Commented [SN5R3]: Noted. Thank you. Commented [SN6]: Include the corner lot driveway diagrams that you included in the Woodhul PUD. Commented [MB7R6]: Okay. See diagram below. Commented [SN8R6]: Noted. Thank you. Page 51 of 68 Kasper - Planned Unit Development Page 4 of 16 For detached residential lots, Georgetown UDC Section 12.03.010.c.3 shall be modified as follows: On local streets, no driveway is permitted closer to a corner than 40’ for lots 50’ and narrower. Measurement shall be taken from the edge of street pavement to the center of the driveway. Georgetown UDC Section 12.03.010.D.5 shall be modified as follows: Up to 10 residential lots shall be allowed to face onto a residential collector street with a driveway spacing of 60 feet measured from the center of the driveway. All other driveways must meet the minimum spacing requirement outlined in the UDC. Driveway access to Single Family or Two Family dwelling units is permitted when spaced 50 feet apart measured center to center. Driveways shall be allowed along Residential or Major Collectors as permitted in the UDC. provided parking is limited to one side and the traffic speed limit along the Collector with proposed driveways shall not exceed 30 miles per hour. Georgetown UDC Section 12.03.010.D.6 shall be modified as follows: On collector streets no driveway is permitted closer to a corner than 50 feet. Commented [SN9]: This requirement is more directly in line with the requirements of the Woodhul PUD. Commented [MB10R9]: We would like to maintain the language as presented to P&Z. There were not objections to our request or justification from the Commission. If the Commission wanted a limitation to the number of units, we would request more than 10, as the Saddlecreek PUD requirement was specific and unique to that layout. Page 52 of 68 Kasper - Planned Unit Development Page 5 of 16 The Kasper development will comply with the Development Standards set forth in Table E.1 Table E.1 – Development Standards RESIDENTIAL USES Base District RS DETACHED 50’ and wider lots See Base District RS DETACHED Narrower than 50 ft. lot no alley Impervious Cover 50%*** 50% Lot Width (minimum) 50 ft. 40 ft. Front Setback (minimum) 20 ft./ 15 ft* 20 ft. Side Setback (minimum) 0/5 ft.** 0/5 ft.** Corner Setback (minimum) 15 ft. 10 ft. Rear Setback (minimum) 10 ft. 10 ft. Building Height (maximum) 35 ft. 35 ft Lot Area (minimum) 5,500 s.f. 4,400 s.f. *Lots with side entry garage may reduce the front setback to 15’. ** Setbacks shall be measured from the outside of the brick. Eaves and overhangs are permitted to encroach within the setbacks a maximum of 18 inches per Section 6.05.020 C7. Zero lot line product is allowed when it follows Section 6.03.050 C3 standards. ***Impervious cover shall be calculated over the entire Kasper subdivision gross site area, excluding the Kenney Fort Blvd. right of way. Individual lots within Kasper may contain up to 60% impervious cover as long as the entire subdivision remains at 50% or less of the gross site area. Tabulation of the impervious cover shall be noted and calculated during the platting stage and included on the plat for each neighborhood. Page 53 of 68 Kasper - Planned Unit Development Page 6 of 16 F. Parkland/Trails/Open Space Open space within Kasper will create a network of trails and parkland that creates distinct neighborhoods and provides pedestrian walkways throughout the community. Per UDC Section 13.05.010, B, Formula for Calculating Area of Parkland, the acreage contributed for parkland shall be pro-rated in an amount equal to one acre for each 50 new detached single family dwelling units. As illustrated on Exhibit D, Open Space Summary, the Kasper PUD Concept Plan illustrates approximately 22.5 acres of public parkland/open space; a mix of greenbelts, open space, trail corridors, parks and water quality amenity lakes. The aforementioned open space shall fully satisfy the park land requirement for Kasper. Phase One of the development shall include the land area for a private amenity center as well as a minimum of five acres of parkland. The remaining parkland dedication will correspond with the adjacent subdivision construction phases. The Kasper community will include a private amenity center within the first phase land dedication that will be built as part of the second phase of the project. The amenity center will contain a resident’s only swimming pool and pool building, as well as open public recreation facilities such as a public parking lot, playground, trail access, and an open play area. Each lot within Kasper will require a $250 parkland fee per the City of Georgetown fee schedule. The Parks and Recreation Director may allow for parkland improvement expenses within Kasper shall be allowed as credit toward the parkland fee requirement. Elements that can be used as credit shall include but not be limited to:  Playgrounds  Parking lots to serve parkland  8’ hike and bike sidewalks  Open recreation fields  Public picnic pavilions  Park site furnishings  Turf and irrigation associated with play fields  Amenity ponds and fountains Public restroom facility Pedestrian circulation will be a vital component of the Kasper community. The following summary describes the location and approximate linear footage of sidewalk proposed within Kasper:  5,500 linear feet of 8’ wide sidewalk will be incorporated into a centralized open space greenbelt and will connect parks and neighborhoods. The sidewalk shall be constructed of concrete. Commented [SN11]: This was not discussed with Parks Director. Are these improvements to be in addition to the 8’ concrete trails? Who will the payment go to? Commented [MB12R11]: I called Kimberly to discuss and we agreed to remove the fee language from the PUD. I misunderstood the fee requirement and thought that a per lot fee was required in addition to the land. Commented [SN13R11]: Noted thank you Page 54 of 68 Kasper - Planned Unit Development Page 7 of 16  4,200 linear feet of 8’ wide, concrete bike and walking sidewalk will be located along the south and west side of Rockride Lane/Kenney Fort Blvd. Water quality ponds may be located along the greenbelt of Kasper and will be designed as an amenity feature that enhances the adjoining residential neighborhoods. All facilities utilized as credit toward parkland requirements shall be open to the public and shall be privately maintained by the Kasper MUD and/or homeowner’s association. G. Roadway Design The Kasper vehicular circulation pattern provides access to all parts of the project from Rockride Lane, Future Kenney Fort Blvd. extension, and Westinghouse Road. See Exhibit C for roadway circulation and right of way classification. Roadway design standards shall be governed by the Georgetown UDC, Section 12.03, Streets unless modified within this PUD. The primary community entry will be from Rockride Lane at the southeastern area of Kasper, as illustrated on Exhibit C. The primary roadway will serve as the entrance for the residential areas of the community. The roadway may be median divided for a segment of the entry experience from Rockride to the amenity center park area and transition to a 65’ Residential Collector or 73’ Major Collector right of way with 30’ of pavement, dependent on the TIA findings for right of way classification. Where the roadway is median divided, a minimum of 20’ of pavement will be maintained on the inbound and outbound portions of the roadway. Other than as provided herein, the remainder of this roadway shall be designed to meet the UDC requirements for a residential collector. Right of way will be reserved for a 135 foot, arterial roadway corridor for the extension of Kenney Fort Blvd. through the project, as illustrated on Exhibit C. Kenney Fort Blvd. is a regional arterial that will provide a major circulation route for the eastern edges of Georgetown and Round Rock. To assist the municipalities and Williamson County in implementing this regional north/south roadway corridor, the Kasper development will dedicate the entire right of way for the arterial to be completed as a capital improvement project. The Kasper development will construct one half of the ultimate arterial roadway section, or construct the entire roadway as a Major Collector, within the boundary of Kasper. A Major Collector classification would accommodate all of the Kasper development traffic, as well as serve a significant amount of additional traffic that could be generated by future development in the immediate area. The City shall coordinate with the developer to determine which construction option is desired within the arterial roadway right of way. Dedication and improvement of Rockride Lane, the portion of the roadway bordering the subject property, shall be determined at the time a traffic impact analysis is completed. Internal local streets within Kasper shall utilize a 50’ right of way with 28’ of pavement measured from back of curb to back of curb. On street parking shall be restricted to one Commented [SN14]: Remove from the PUD requirements for Kenny Fort will be covered in the MUD. Commented [MB15R14]: We would like to maintain this language in the PUD, as presented to P&Z. In previous projects, staff has had some issues referring to consent agreements when reviewing subdivision plans, so we believe it would be best to keep the requirements outlined in the PUD. Commented [SN16R14]: Staff recommends the following wording: A minimum reserve of 115 feet of ROW and improvement of one-half of the ultimate minor arterial roadway section within the boundary of Kasper shall be requiremend. Additional improvements may be required as a result of the City’s review of a traffic impact analysis for the subdivision including contribution to construction of the remaining one-half of the minor arterial roadway section. Page 55 of 68 Kasper - Planned Unit Development Page 8 of 16 side of the street. A sign will be placed at entries into residential neighborhoods stating that parking is restricted to one (1) side of the street. The final sign language is to be determined and agreed to by the City and Applicant prior to installation. Roadway Landscaping: Along the extension of the Kenney Fort Boulevard arterial, landscaping shall be provided between the back of the lots and the right way in the following quantities:  A minimum of 5’ of landscape area will be provided between the right of way and the back of lots, with an average width of 10’  2 shade trees, minimum of 3 inch caliper and 5 five gallon shrubs for every 1,000 square feet of landscape area located between the right of way and the back of lots Landscape in Right of Way: The Kasper PUD shall allow the planting of trees and vegetation within internal medians and public right-of-ways. The Developer or Homeowners Association is responsible for landscape maintenance and irrigation within the landscape lots and right of way. Landscape within the right of way shall require a license agreement with the City. Tree species, spacing and irrigation requirements shall be approved by the City Arborist. If a median is planned within the ultimate build out section of the Kenney Fort Blvd. arterial, the City shall be responsible for landscaping, irrigation and maintenance within the median. H. Signage Exhibit E illustrates the location of signage within the Kasper community. Subdivision Entry Signs (see Exhibit F) Primary subdivision entry monument signs shall be located along Rockride Lane and the future extension of Kenney Fort Blvd., as illustrated on Exhibit E. A conceptual design for the freestanding monument signs is illustrated on Exhibit F. The sign scale and dimensions shall not exceed the dimensions illustrated on Exhibit F. Exhibit F shall replace the size restrictions described in Chapter 10 of the Unified Development Code. The signs shall be located a minimum of 20’ from the right of way of Rockride Lane, Kenney Fort Blvd. and Westinghouse Road. A minimum of 1,000 s.f. of landscape plant bed shall be provided around each Subdivision Entry Sign. Plant material should be of a native and/or adapted species. Plants should be selected from the booklet titled, Native and Adapted Landscape Plants, an earthwise guide for Central Texas, 5th Edition, 2013, created by the Texas Commented [SN17]: This is not different from what is allowed. Please remove. Commented [MB18R17]: We want to maintain this language in the PUD to preserve a consistent roadway treatment over the life of the project. In the event the City revises the UDC road classifications in the future, we think it is prudent to keep this language in the PUD. Commented [SN19R17]: I understand. Commented [MB20]: We are requesting to maintain the Kenney Fort Blvd. language in the PUD and thus would like to maintain this provision as well. Commented [SN21R20]: In lieu of establishing specific requriements and assignments at this time staff requests improvements be deterimend upon review of the traffic impact analysis. Page 56 of 68 Kasper - Planned Unit Development Page 9 of 16 Cooperative Extension, Grow Green and the Ladybird Johnson National Wildflower Center. Residential Neighborhood Monument Signs Neighborhood signs may be located throughout the community as noted on Exhibit E and illustrated on Exhibit F. The residential neighborhood signs shall not exceed the dimensions illustrated on Exhibit F for Neighborhood Entry Monuments. A minimum of 300 s.f. of landscape plant bed shall be provided around each Residential Neighborhood Monument Sign. Plant material should be of a native and/or adapted species. Plants should be selected from the booklet titled, Native and Adapted Landscape Plants, an earthwise guide for Central Texas, 5th Edition, 2013, created by the Texas Cooperative Extension, Grow Green and the Ladybird Johnson National Wildflower Center. I. Fencing and Walls A masonry residential boundary wall shall be constructed in conformance with the UDC. will be provided along the rear of all lots that back onto an unloaded collector or higher level roadway. The masonry wall shall consist of brick, stone or pre cast concrete fencing. All lots within Kasper which back onto open space or greenbelts shall be required to utilize a wrought iron view fence. J. Miscellaneous Provisions Amendments: Amendments to this PUD shall follow the amendment process outlined in the UDC Exhibits. All exhibits described herein and attached hereto are fully incorporated into this Agreement by this reference for all purposes. Commented [MB22]: We would like to maintain the language that lots backing up to unloaded collector roads will have masonry walls. If the UDC is amended in the future, we do not want an unforeseen requirement for walls on the boundary of the project. Can you expand upon your definition of a residential boundary wall? Commented [SN23R22]: Noted. Sec. 8.07.060 of the UDC establishes requriemetns. Page 57 of 68 Kasper - Planned Unit Development Page 10 of 16 Exhibit B Field Notes Page 58 of 68 Kasper - Planned Unit Development Page 11 of 16 Page 59 of 68 Kasper - Planned Unit Development Page 12 of 16 Page 60 of 68 Kasper - Planned Unit Development Page 13 of 16 Exhibit C Page 61 of 68 Kasper - Planned Unit Development Page 14 of 16 Exhibit D Page 62 of 68 Kasper - Planned Unit Development Page 15 of 16 Exhibit E Page 63 of 68 Kasper - Planned Unit Development Page 16 of 16 Exhibit F Conceptual Entry Monument Signs Page 64 of 68 C I T Y O F G E O R G E T O W N G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J REZ-2016-001 C L I F F S T E R I D G E L I N E B L V D P O T T E R S P E AKWAY O L D P E A K R D R O C K R I D E L N Z E N I T H R D G R A N G E R R D P R E C I P I C E W A Y W E S T I N G H O U S E R D A V A L A N C H E A V E P L A T E A U T R L P INN A C L E D R C R 1 1 0 SAMHOUSTON AV E REZ-2016-001 Exhibit #1 Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only 0 1,500 3,000Feet ¯ Le ge ndSiteParcelsCity LimitsGeorgetown ETJ W e s ti n g h o u s e R d S a m H o u s t o n Ave S E I n n e r L o o p SamHoustonAve South w est e r n B l v d ")1460 R o c k ri d e L n R o c k ri d e L n Tera vis t a Xing SiteCity Lim its Street Site ³ Location M ap Page 65 of 68 G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J G e o r g e t o w n E T J REZ-201 6-0 01 FM 1460 C L I F F S T A V A L A N C H E A V E E R I D G E L I N E B L V D P O T T E R S P E A K WAY G R E E N S L O P E L N Z E N I T H R D R O C K R I D E L N W E S T I N G H O U S E R D P R E C I P I C E W A Y P L A T E A U T R L P I N N A C L E D R C U L E B R A D R B E L L G I N R D T E L L U R I D E D R S O U T H W E S T E RN BLVD M A P L E S T SAM HOUSTONAVE CR 1 1 0 0 2,000 4,000 Feet Co o rdi nate System : Texas State Plane/Central Zo ne/N A D 83/US FeetCartographic D ata For Gener al Plann ing Pu rposes Only ¯ LegendSiteParcelsCity LimitsGeorgetown ETJ Future Land Use / Overall Transportation Plan Exhibit #2REZ-2016-001 Legend Tho roughfare Fu tu re Land Use Institutional Reg ional Commercial Com m unity Commercial Em ploym ent Center Low Density Residential Minin g Mixed Use Community Mixed Use Neighborhood Center Moder ate Density Residential Open Space Sp ecia lty Mixed Use Area Ag / Rur al Residential W e s ti n g h o u s e R d ")146 0 R o c k ri d e L n Tera vis t a X i ng Site ³City L im its Stre e t Site Ex isting Collector Ex isting Freeway Ex isting Major Arterial Ex isting Minor Arterial Ex isting Ramp Proposed Collec tor Proposed Freeway Propsed Fro ntage Road Proposed Majo r Arterial Proposed Mino r Arterial Proposed Railroad High Density Residential 1460 Page 66 of 68 C I T Y O F G E O R G E T O W N G e o r g e t o w n E T J REZ-2016-001 R O C K R I D E L N C L I F F S T E R I D G E L I N E B L V D P O T T E R S P E AKWAY O L D P E A K R D SAMHOUSTON A V E T O L T E C T R L Z E N I T H R D G R A N G E R R D M A P L E S T W E S T I N G H O U S E R D A V A L A N C H E A V E PINN A C L E D R C R 1 1 0 Zoning InformationREZ-2016-001Exhibit #3 ¯ Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only 0 1,500 3,000 Feet Le ge ndSiteParcelsCity LimitsGeorgetown ETJ W e s ti n g h o u s e R d S a m H o u s t o n Ave SamHoustonAve South w est e r n B l v d R o c k ri d e L n R o c k ri d e L n Tera vis t a Xing ³SiteCity Lim its Street Site D B W o o d R d Page 67 of 68 REZ-2016-001 T O L T E C T R L R O C K R I D E L N O L D P E A K R D M A P L E S T P R E C I P I C E W A Y SAM HOUSTON A V E W E S T I N G H O U S E R D A V A L A N C H E A V E C R 1 1 0 H A W K E Y E P O I N T R D P I N N A C L E D R P L A T E A U T R L Le ge ndSiteParcelsCity LimitsGeorgetown ETJ Coordinate System: Texas State Plane/Central Zone/NAD 83/US FeetCartographic Data For General Planning Purposes Only ¯0 1,500 3,000Feet Exhibit #4REZ-2016-001 W e s ti n g h o u s e R d S a m H o u s t o n Ave S E I n n e r L o o p Sam HoustonAve South w est e r n B l v d ")1460 R o c k ri d e L n R o c k ri d e L n Tera vis t a Xing S EInnerLoop Site City Lim its Street Site ³ Aerial 29 Page 68 of 68