Loading...
HomeMy WebLinkAboutAgenda CC 11.22.2005Notice of Meeting of the Governing Body of the City of Georgetown, Texas Tuesday, November 22, 2005 The Georgetown City Council will meet on Tuesday, November 22, 2005 at 06:00:00 PM at City Council Chambers, at the northeast corner of Seventh and Main Streets, Georgetown, Texas. If you need accommodations for a disability, please notify the city in advance. An agenda packet, containing detailed information on the items listed below, is distributed to the Mayor, Councilmembers, and the Georgetown Public Library no later than the Saturday preceding the council meeting. The library's copy is available for public review. Please Note: This City Council Meeting will be video taped live without editing and shown on the local cable channel. Executive Session Regular Session to convene and continue Executive Session, if necessary In compliance with the Open Meetings Act, Chapter 551, Government Code, Vemon's Texas Codes, Annotated, the items listed below will be discussed in closed session and are subject to action in the regular session that follows. A Sec.551.071: Consultation with Attorney - Advice from attorney about pending or contemplated litigation and other matters on which the attorney has a duty to advise the City Council, including agenda items - Discussion and possible action regarding the "Application of the City of Leander to Amend Water Certificate of Convenience and Necessity (CCN) No. 10302 and Sewer CCN No. 20626 in Williamson and Travis Counties, Application Nos. 34789-C and 34790-C," SOAH Docket No. 562-05-7095; TCEQ Docket No. 2005-0864-UCR B Sec.551.072: Deliberations Regarding Real Property - Consideration and possible action to authorize staff to enter into negotiations to purchase land for a pads on the west side of IH35 - Discussion and possible action concerning the acquisition of +5.24 acres of land located on SE Innedoop at CR 110 from Williamson County for the construction of a new electric substation. - Discussion and possible action concerning the acquisition of +3.83 acres of land located on CR 116 from the W.D. Kelley Foundation for the construction of a new electric substation. Regular Session - To begin no earlier than 06:00 PM (Council may, at any time, recess the Regular Session to convene an Executive Session at the request of the Mayor, a Councilmember, or the City Manager for any purpose authorized by the Open Meetings Act, Texas Government Code Chapter 551.) C Call to Order D Pledge of Allegiance E Comments from the dais - Welcome to Audience and Opening Comments -- Mayor Gary Nelon - Review of new procedure for addressing the City Council - Announcement of vacancies for one position on the Airport Advisory Board and one alternate position on the Building Standards Commission F Announcements and Comments from City Manager City Council Agenda/November 22, 2005 Page 1 of 7 Pages G Public Wishing to Address Council H Action from Executive Session Statutory Consent Agenda The Statutory Consent Agenda includes non -controversial and routine items that Council may act on with one single vote. A counciimember may pull any item from the Consent Agenda in order that the council discuss and act upon it individually as part of the Regular Agenda. I Consideration and possible action to approve the minutes of the Council Workshop on Monday, November 7, and the regular Council Meeting on Tuesday, November 8, 2005 — Sandra D. Lee, City Secretary J Consideration and possible action to direct staff to enter into a lease/purchase agreement with Pitney Bowes for a DM1000 Digital Postage Machine —Shirley Rinn, Administrative Manager/Mail Services Supervisor and Paul E. Brandenburg, City Manager K Consideration and possible action regarding the recommendation by the Convention and Visitors' Bureau Board for the approval of an allocation of $750 to the GHS Boys' Basketball Booster Club in Hotel Occupancy Tax (HOT) funds — Shelly Hargrove, Tourism Director and Main Street Manager L Consideration and possible action to approve the purchase of three LaserJet Printers from Hewlett-Packard Corporation in the amount of $26,583.00 through the State of Texas DIR contract — Marsha Iwers, Acting Purchasing Manager and Micki Rundell, Director of Finance and Administration M Consideration and possible action to approve the purchase of cellular phone service from Nextel dba Sprint in the amount of $44,050.00 through the State of Texas Purchasing contract — Marsha Iwers, Acting Purchasing Manager and Micki Rundell, Director of Finance and Administration N Consideration and possible action to accept the City's Quarterly Financial Report, which includes the Investment Report for both the City of Georgetown and the Georgetown Transportation Enhancement Corporation (GTEC) for the quarter ended September 30, 2005 — Laurie Brewer, Controller and Micki Rundell, Director of Finance & Administration Consideration and possible action to renew the contract between the City of Georgetown and Prime Controls, LP., of Carrollton, Texas, for Supervisory Control And Data Acquisition (SCADA) system technical services in the amount of $48,500.00 — Michael W. Mayben, Energy Services Manager and Jim Briggs, Assistant City Manager for Utility Operations Consideration and possible action to authorize the approval of the annual license renewal, system support, software activation and hardware repair for the AMR Genesis and MVRS system between the City of Georgetown and Itron Incorporated, in an amount not to exceed $46,048.00 — Michael W. Mayben, Energy Services Manager and Jim Briggs, Assistant City Manager for Utility Operations Q Consideration and possible action on a Preliminary Plat for a Resubdivision of Cedar Hollow Crossing, Block B, Lot 15, located on Lost Oak Cove, with waivers to the Unified Development Code —Carla Benton, Development Planner and Bobby Ray, AICP, Acting Director of Planning and Development R Consideration and possible action on a Preliminary Plat for a Resubdivision of Lakewood Estates, Block E, Lots 14-15, located at 6839 Lakewood Drive South, with waivers to the Unified Development Code — Mclissa McCollum, AICP, Development Planner and Bobby Ray, AICP, Acting Director of Planning and Development S Consideration and possible action on a Preliminary Plat for 120.59 acres out of the Lewis P. Dyches Survey, to be known as Walnut Springs, located at the intersection of F.M. 3405 and CR 261 — Melissa McCollum, AICP, Development Planner and Bobby Ray, AICP, Acting Director of Planning and Development. T Consideration and possible action on a Final Plat of 33.2569 acres in the William Addison Survey to be known as Pinnacle Subdivision, Phase 1, located South of the Inner Loop and east of the future extension of Maple Street — Melissa McCollum, AICP, Development Planner and Bobby Ray, AICP, Acting Director of City Council Agenda/November 22, 2005 Page 2 of 7 Pages Planning and Development U Consideration and possible action on permitting Planning and Development to apply for a grant of approximately $20,883.50 from the Preserve America Grants through the National Park Service -- Bobby ^Ray, AICP, Acting Director of Planning and Development V Consideration and possible action to authorize a Boundary Line Agreement with the Steenken Family Partnership to establish the common boundary line of City -owned property located at 816 S. Main Street (Fire Department) and the adjoining Steenken Family property to the north currently located at 812 S. Main Street. and currently owned by The Steenken Family Partnership -- Patricia E. Carts, City Attorney Legislative Regular Agenda Council will individually consider and possibly take action on any or all of the following items: W Discussion and possible action regarding concerns expressed by the Georgetown Animal Outreach about Petland Stores -- Paul Brandenburg, City Manager X Consideration and possible action on a resolution expressing official intent to reimburse net costs for the purchase of the 2005/06 General Capital Projects and Equipment, as well as Electric Improvements, not to exceed $7,168,000 with proceeds from bonds that will be issued at a later time -- Laurie Brewer, Controller and Micki Rundell, Director of Finance & Administration Y Update on proposed issuance of $7.1 million in General Obligation bonds for construction of the new library— Micki Rundell, Director Finance & Administration Z Discussion and possible action to adopt the first recommendation in the Humane Society of the United States Animal Services Consultation Report, which is to solicit and organize interested individuals to serve � on an Animal Services Task Force -- Paul Brandenburg, City Manager E1 Contracts and Agreements J 1. Discussion and possible action to approve the extension of a long-term lease with the Georgetown Chamber of Commerce for 1.88 acres of property at the corner of Stadium Drive and Austin Avenue -- Paul E. Brandenburg, City Manager OConsideration and possible action to renew the contract between the City of Georgetown and ElectSolve Technology Solutions and Services Incorporated to provide AMR System Data Services in an amount not to exceed $77,600.00 -- Michael W. Mayben, Energy Services Manager and Jim Briggs, Assistant City Manager for Utility Operations 3. Consideration and possible action to renew the contract with Dataprose, Inc as the City's vendor for utility bill printing and mailing services, and approve funding, at a cost of $135,800 for the year — Kathy Ragsdale, Utility Office Director and Micki Rundell, Director of Finance and Administration 4. Discussion and possible action to recommend authorization of an interlocal agreement with the City of Round Rock for Electric Utility Service -- Micki Rundell, Director of Finance and Administration 5. Consideration and possible action to contract with Ampersand Agency (formerly Montgomery and Associates) to conduct the 2005/06 City of Georgetown Quality of Life Citizen Survey, in an amount not to exceed $20,000 -- Micki Rundell, Director of Finance and Administration BB kafwarded from the Georgetown Utility System (GUS) Advisory Board S 1. Consideration and possible recommendation to approve a contract amendment between the City of Georgetown and Kasberg, Parker & Associates for professional services related to the design of the Phase III EARZ remediation in the amount of $61,600.00 -- Glenn Dishong, Water Services Manager and Jim Briggs, Assistant City Manager for Utilities. OConsideration and possible recommendation to approve a contract between the City of Georgetown and GSW W, Inc for engineering services related to the fourth phase of the Edwards Aquifer Recharge Zone testing program and approve a budget of $74,730.00 — Glenn Dishong, Water Services Manager and Jim Briggs, Assistant City Manager for Utilities City Council Agenda/November 22, 2005 Page 3 of 7 Pages CC Forwarded from the Georgetown Transportation Enhancement Corporation (GTEC) Consideration and possible action to amend the engineering contract with Kasberg, Patrick & Associates, for services relating to change in scope of the Southeast Arterial (SE One) project in the amount of $779,600.00 — Thomas Benz, Systems Engineering Manager, and Jim Briggs, Assistant City Manager for Utilities. DD Consideration and possible action regarding an invitation to join the Board of the Austin -San Antonio Intermunicipal Rail District — Tom Yantis, Assistant City Manager EE Consideration and possible action to reappoint of members of the Wolf Ranch Tax Increment Reinvestment Zone Board of Directors — Tom Yantis, Assistant City Manager FF Consideration and possible action to authorize staff to proceed with some or all of the recommended action items in the Austin Ave. report prepared by TND Engineering and accepted by Council at their November 8, 2005 meeting — Tom Yantis, Assistant City Manager GG Second Readings 1. Second Reading of an Ordinance repealing and replacing Chapter 12.32 of the Code Of Ordinances pertaining to the Georgetown Municipal Airport Use Regulations and the Minimum Standards for Commercial and Non -Commercial Operations — Travis McLain, Airport Manager and Tom Yantis, Assistant City Manager 2. Second Reading of an Ordinance Approving a Major Revision to a Planned Unit Development - Development Plan incorporating a new site plan and revised development standards pursuant to the Airport Master Plan Update for the Georgetown Municipal Airport located at 500 Terminal Drive, and a Rezoning from a base district of RS, Residential Single-family to IN, Industrial -- Bobby Ray, AICP, Acting Director of Planning and Development 3. Second Reading of an ordinance providing for the adoption of the Georgetown Municipal Airport Functional Plan Element as a new element of the Century Plan — Edward G. Polasek, AICP, Chief Long Range Planner and Bobby Ray, AICP, Acting Director of Planning and Development 4. Second Reading of an Ordinance Amending Section 8.04.80 of the Code of Ordinances regarding burning of refuse to allow prescribed bums under certain circumstances in accordance with state laws and regulations — Tom Yantis, Assistant City Manager 5. Second Reading of an Ordinance adding a new definition to Section 12.20.010 to the Code Of Ordinances pertaining to U. S. Army Corps Of Engineers Park Land; adding a new section 12.20.090 to be entitled "Special Rules For U. S. Army Corps Of Engineers Park Land;" adopting by reference the Federal Rules and Regulations found in Title 36 of The United States Code, Chapter III, Part 327; and providing for the enforcement of such Federal Regulations by City Personnel on U. S. Army Corps of Engineers Park Land — Tom Yantis, Assistant City Manager 6. Second Reading of an Ordinance exempting federally -owned buildings located within the City of Georgetown from Title 15, Chapter 15.04, Section 15.04.010 relating to the adoption of the 2003 International Building Code — Tom Yantis, Assistant City Manager 7. Second Reading of an ordinance designating a continuous geographic area within the City of Georgetown, generally described as Lot 1, Block 1 of the Park Central Subdivision, consisting of approximately 7.09 acres, as a Reinvestment Zone for property tax abatement purposes, pursuant to Chapter 312 of the Texas Tax Code -- Mark Thomas, Economic Development Director and Paul Brandenburg, City Manager HH Consideration and possible action regarding a Personal Property Tax Abatement Agreement between Tumco Tools & Instruments, Inc., the City of Georgetown, and Williamson County -- Mark Thomas, Economic Development Director and Paul Brandenburg, City Manager II Public Hearings/First Readings 1. First Reading of an ordinance amending the previous year 2004/05 Annual Operating Plan Element (Budget) to offset variances in various fund budgets for increases in expenditures that are tied to service requests, revenue collection rates, donations, project timing, grants and payments to City Council Agenda/November 22, 2005 Page 4 of 7 Pages bond escrow agent for refunding bonds — Laurie Brewer, Controller and Micki Rundell, Director of Finance & Administration OFirst Reading of an ordinance amending Section 10.12.090 of the Code of Ordinances relating to speed limits and speed zones; eliminating the school speed zone on Northwest Blvd. between Janis Drive and IH -35 Frontage Road; and adopting a school speed zone on Woodlake Drive between FM 2338 and Wildwood Drive — Jimmy Carranco, Streets Foreman; Mark Miller, Transportation Services Manager; and Jim Briggs, Assistant City Manager for Utility Operations 3. Public Hearing to Consider a Rezoning from AG, Agriculture to PUD, Planned Unit Development for 41.40 acres in the Frederick Foy Survey, to be known as Sun City Neighborhood ThlrtyTwo, located about two miles northwest of the intersection of Del Webb Blvd. and Sun City Blvd. — Melissa McCollum, AICP, Development Planner and Bobby Ray, AICP, Acting Director of Planning and Development. 4. First Reading of an Ordinance Rezoning from AG, Agriculture to PUD, Planned Unit Development for 41.40 acres in the Frederick Foy Survey, to be known as Sun City Neighborhood ThlrtyTwo, located about two miles northwest of the intersection of Del Webb Blvd. and Sun City Blvd. -- Melissa McCollum, AICP, Development Planner and Bobby Ray, AICP, Acting Director of Planning and Development. 5. Public Hearing to Consider Rezoning 15.63 acres out of the Sutherland and Monroe Surveys from C-1, Local Commercial District to C-3, General Commercial District, located on Williams Drive southeast of Jim Hogg Road also known as Fountainwood Plaza — Bobby Ray, AICP, Acting Director of Planning and Development 6. First Reading of an Ordinance Rezoning 15.63 acres out of the Sutherland and Monroe Surveys from C-1, Local Commercial District to C-3, General Commercial District, located on Williams Drive southeast of Jim Hogg Road also known as Fountainwood Plaza — Bobby Ray, AICP, Acting Director of Planning and Development 7. Public Hearing to Consider Rezoning a .26 and .18 acre tract out of the Porter Survey, from OF, Office District and RS, Residential Single-family District to C-1, Local Commercial, located at 1502 Williams Drive — Bobby Ray, AICP, Acting Director of Planning and Development - Bobby Ray, AICP, Acting Director of Planning and Development 8. First Reading of an Ordinance Rezoning a .26 and .18 acre tract out of the Porter Survey, from OF, Office District and RS, Residential Single-family District to C-1, Local Commercial, located at 1502 Williams Drive — Bobby Ray, AICP, Acting Director of Planning and Development 9. Public Hearing to Consider Rezoning Legend Oaks Section II, Lots 1 through 6 from RS, Residential Single -Family to C-1, Local Commercial located on the south side of State Highway 29, east of River Chase Boulevard — Bobby Ray, AICP, Acting Director of Planning and Development 10. First Reading of an Ordinance Rezoning Legend Oaks Section ll, Lots 1 through 6 from RS, Residential Single -Family to C-1, Loral Commercial located on the south side of State Highway 29, east of River Chase Boulevard — Bobby Ray, AICP, Acting Director of Planning and Development 11. Public Hearing to Consider Rezoning a 0.149 acre portion and a 0.16 acre portion of Lost Addition, Block 64, from RS, Residential Single-family to C-2, Downtown Commercial, located at 1005 and 1009 Rock Street. — Rebecca Rowe, Historic District Planner and Bobby Ray, AICP, Acting Director of Planning and Development. 12. First Reading of an Ordinance Rezoning a 0.149 acre portion and a 0.16 acre portion of Lost Addition, Block 64, from RS, Residential Single-family to C-2, Downtown Commercial, located at 1005 and 1009 Rock Street — Rebecca Rowe, Historic District Planner and Bobby Ray, AICP, Acting Director of Planning and Development 13. First Reading of an ordinance of a Century Plan Amendment to change the Future Land Use Plan designation from Residential to Office/Retail/Commercial for a 0.26 and 0.18 acre tract in the Nicholas Porter Survey, also known as Extraco Bank, located at 1502 Williams Drive — Edward G. Polasek, City Council Agenda/November 22, 2005 Page 5 of 7 Pages Chief Long Range Planner and Bobby Ray, AICP, Acting Director of Planning and Development 14. Public Hearing on the annexation into the City of approximately 3100 acres consisting of various tracts of land owned by the United States Army Corps of Engineers adjacent to Lake Georgetown and portions of Cedar Breaks Road R.O.W. in the Cedar Breaks Park area and lake dam area, referred to as Annexation Area 9a — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 15. Public Hearing on the annexation into the City of approximately 139 acres of land out of the D. Wright Survey, being: Lots 1 and 2 of the Dicotech Subdivision and a 2.1601 acre tract of land owned by Yuh-Jaan Way & Yecu-Chyn Way, recorded in Vol. 2173, Pg. 319 of the Official Records Of Williamson Co., Texas, and approximately 26.3 acre portion of Williams Drive R.O.W. that begins at the current city limits at Lakeway Drive and Booty's Crossing Road and extends northwest to the intersection of Shell Road, referred to as Annexation Area 13a — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 16. Public Hearing on the annexation into the City of approximately 131.3 acres of land from the D. Wright Survey that lies south of Williams Drive and east of D.B. Wood Road, including an approximately 4.5 acre portion of D.B. Wood Road R.O.W. that begins at the intersection of Williams Drive and continues southwest for approximately 2380 ft, referred to as Annexation Area 13b — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 17. Public Hearing on the annexation into the City of all lots within the Enclave Subdivision and the R.O.W. of Rustle Cove East, Sutton Place and Enclave Trail, and Faith Lutheran Church Subdivision and Faith Lutheran Church, Phase Two Subdivision, and approximately 95 acres out of D. Wright Survey, and a portion of Booty's Crossing Road R.O.W. beginning approximately 220 ft. west of Oak Ridge Circle and extending 1320 ft. westward, referred to as Annexation Area 13c — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 18. Public Hearing on the annexation into the City of all of Buzzard Branch Subdivision and an approximately 5 acre portion of Booty's Crossing Road R.O.W. that begins at the current city limits near Kathi Lane and extends northwest to a point which is 220 ft. west of Oak Ridge Circle, referred to as Annexation Area 13d -- Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 19. Public Hearing on the annexation into the City of various tracts of land out of the A. Flores Survey, totaling approximately 199.2 acres, and approximately 22.8 acres of R.O.W., including: all of East Drive; a portion of CR 151 beginning at the intersection of Austin Ave. and extending approximately 4920 ft. northeasterly to the intersection of CR 152; a portion of CR 152, beginning at the intersection of CR 151 and extending approximately 1500 ft. southeasterly to the current city limits; a portion of NE Inner Loop beginning at the intersection of Austin Ave. and extending southeasterly approximately 4300 ft. to the current city limits, referred to as Annexation Area 16a — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 20. Public Hearing on the annexation into the City of approximately 240 acres owned by Georgetown Railroad Co., Inc., out of the L.J. Dyches Survey and the William Addison Survey, and an approximately 10 acre portion of S.E. Inner Loop R.O.W. that begins at FM 1460 and extends northeast for approximately 2000 ft. to the current city limits, referred to Annexation Area 19b — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 21. Public Hearing on the annexation into the City of a single land parcel, located south of SE Inner Loop Road and west of the abandoned railroad R.O.W., totaling approximately 293 acres from the W. Addison Survey, referred to as Annexation Area 19c — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 22. Public Hearing on the annexation into the City of approximately 0.66 acre portion out of Tract A, Planned Unit Development of Sun City, Georgetown, Phase 2, Neighborhood Ten -A Subdivision, and approximately 6.8 acre portion of Williams Drive R.O.W. that begins at the current city limits located at City Council Agenda/November 22, 2005 Page 6 of 7 Pages the southeast comer of Casa Loma Subdivision and extends northwesterly for approximately 2950 ft. to the current city limits located southeast of Lakewood Drive South, referred to as Annexation Area 25 -- Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 23. Public Hearing on the annexation into the City of a strip of land, 1,001 ft. wide, containing approximately 396 acres out of the J. Thompson Survey, located in part north of the current city limits along RR 2243 and in part north of the R.O.W. of RR 2243, beginning at the current city limits at Riverview Estates and extending westerly to CR 176, and an approximately 26 acre portion of RR 2243 R.O.W. that begins at the current city limits and extends westerly to CR 176, referred to as Annexation Area 26 -- Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 24. Public Hearing on the voluntary annexation into the City of 10.04 acres, more or less, platted as Legend Oaks 11 Subdivision, located south of State Highway 29, approximately one half mile west of IH 35 — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 25. Public Hearing on the voluntary annexation into the City of 27.47 acres of Right of Way, more or less, in Isaac Donagan Survey and Joseph Fish Survey, for D.B. Wood Road Right of Way — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 26. Public Hearing on the voluntary annexation into the City of 51.34 acres of Right of Way, more or less, in the Antonio Flores Survey and John Berry Survey, for Inner Loop East Right of Way — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 27. Public Hearing on the voluntary annexation into the City of 3.0251 acres of Right of Way, more or less, in the Antonio Flores Survey and John Berry Survey, for Inner Loop North East and Sudduth Drive Right of Way — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner 28. Public Hearing on the voluntary annexation into the City of 5.252 acres of Right of Way, more or less, in the Clement Stubblefield Survey and Joseph Pulsifer Survey, for County Road 265 Right of Way — Bobby Ray, AICP, Acting Director Planning and Development and Edward G. Polasek, AICP, Chief Long Range Planner JJ Discussion and possible action to provide staff direction on finalized annexation areas — Edward G. Polasek, AICP, Chief Long Range Planner and Bobby Ray, AICP, Acting Director of Planning and Development of I, Sandra Lee, City Secretary for the City of Georgetown, Texas, do hereby certify that this Notice of Meeting was posted at City Hall, 113 E. 8th Street, and on the bulletin board located outside of the Council Chambers, 101 East 7th Street, places readily accessible to the general public at all times, on the_ day of , 2005, at , and remained so posted for at least 72 continuous hours preceding the scheduled time of said meeting. Sandra Lee, City Secretary City Council Agenda/November 22, 2005 Page 7 of 7 Pages Council Meeting Date: November 22, 2005 AGENDA ITEM COVER SHEET Item No. SUBJECT: Consideration and possible action to renew the contract between the City of Georgetown and Prime Controls, LP., of Carrollton, Texas, for Supervisory Control And Data Acquisition (SCADA) system technical services in the amount of $48,500.00. ITEM SUMMARY: In May, 2001, the Georgetown City Council approved the contract to provide technical services for the City's SCADA System. This contract is a renewable annually, for up to five terms, upon the agreement of both the City and Prime Controls, LP. This year, both the City of Georgetown and Prime Controls, LP. have agreed to renew the contract from December 2005 through November 2006. Therefore staff recommends Council approval of the contract renewal in the amount of $48,500.00. SPECIAL CONSIDERATIONS: None. FINANCIAL IMPACT: Funds not to exceed the amount of $48,500.00 are to be paid from the Electric and AMR Operations accounts as work is completed. GUS BOARD RECOMMENDATION: None - Cost is below threshold for GUS review. STAFF RECOMMENDATION: The staff recommends approval of the renewal of the SCADA contract with Prime Controls. COMMENTS: NONE ATTACHMENTS: 1. Letter of agreement from Prime Controls, LP. Incorporated. tted 6y/ Michaklyl jNNaybenJim Energy ices Manager City Manager for Uti s PRIME �WoNMoLS 815 OFFICE PARK CIRCLE I LEWISVILLE, TX 75057 PHONE 972.221-4849 1 FAX 972-420.4842 October 14, 2005 To: City of Georgetown Attn: Mike Mayben Tel: (512) 930-3558 Fax: (512) 930-3559 Ref: City of Georgetown Service Agreement Prime Letter:Geo_Serv_Agr101405 Mr. Mayben We are at that time of year when our Professional Services agreement with the City of Georgetown comes up for renewal. Prime Controls has very much enjoyed our relationship with the City and would like for the service agreement to be renewed for another year. We feel that the ongoing relationship has been beneficial for both of our organizations. Prime Controls appreciates the opportunity to have served the City of Georgetown over the past several years and we look forward to serving the city in the future. Please let me know what needs to be done in orders to renew the agreement. Thank you for your time and consideration, and I look forward to hearing from you soon. Sincerely, Prime Controls, LP James R. McMillon Agenda Item Check List &MMU Financial Impact Agenda Item: SCADA Technical Services Agenda Item Subject: Renewal of SCADA Technical Services with Prime Controls Is this a Capital Improvement Yes 0 No Project: Council Date: 11/22/2005 link to Agenda database => 0 Need Help? Was it budgeted? Is it within the approved budgeted amount? If not, where is the money coming from? G/L Account Number Amount Going to Council Is there something (budgeted) that won't get done because you are spending these funds? If so, please explain. • Yes O No 0 Yes O No 610 -115 -5303 -AM $18,500 610-106-5606-00 $24,000 611-101-6619-00 $6,000 $ 48,500.00 Yes • No Will this have an impact on the next year's Yes 0 No budget? If so, please explain. Does this project have future revenue Yes 0 No impact? Year: Department: If so, how? Identify all on-going costs (i.e., insurance, annual maintenance fees, licenses, operational costs, etc...). Estimated staff hours: Cross -divisional impact: Yes 0 No If so, what division(s)? Prepared by: Walter Koopmann Date: 11/08/2005 w Agenda item Checklist: Approved on 11/08/2005 Approvers ITitle lAssigned INotified Received IStatus Changed IStatus Jim Briggs Assistant City 11/08/2005 11/08/2005 11/08/2005 11/08/2005 Approved Jose Lara Manager 11/08/2005 11/08/2005 11/08/2005 11/08/2005 Approved Utility Financial Analyst Approval Cycle Settings Council Meeting Date: November 22, 2005 Item No. P AGENDA ITEM COVER SHEET SUBJECT: Council consideration and possible action to authorize the approval of the annual license renewal, system support, and software activation and hardware repair for the AMR Genesis and MVRS system between the City of Georgetown and Itron Incorporated in an amount not to exceed $46,048.00 IYY�1Li.YII4I V I.\C��ii Staff is requesting authorization to renew AMR Network supplies, support, repair services and software for the City's AMR system from Itron Incorporated for 2006. Itron has been providing this support since December of 2001. SPECIAL CONSIDERATIONS: This is a proprietary software application and maintenance agreement and does not require competitive bid. FINANCIAL IMPACT: Funds not to exceed the amount of $46,048.00 will be taken from the Electric/AMR operations account number 610 -115 -5303 -AM. COMMENTS: None. ATTACHMENTS: Itron Summary Billing Report tted By:Y Michael W. Ma n Jim gg 11 Energy Service Manager nt ty Manager- ti 'ties IT) System Support Pricing ltrdrn GEORGETOWN, CITY OF (TX) Knowk4ye NShvv Customer Number. 46588 !"'fall Rate Date Qty Deserfptio" per Unit 3en-06 Feb -06 Mar -06 Apr -06 May -06 Jun -06 Jul -06 Aug -06 Sep -06 Oct -06 Nov -06 Dec -06 Total Hardware 2/1/1997 8 ASSY,CCU,120V W/ BACK $4.50 36.00 36.00 36.00 36.00 36.00 36.00 36.00 36.00 36.00 36.00 36.00 36.00 432.00 2/1/1999 367 ASSY,CCU,120V W1 BACK $4.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 1,741.50 20,898.00 10/12001 5 CCU ASSY 120V, WBACKU $4.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 22.50 270.00 1/12001 6 CCU ASSY 120V, WBACKU 54.50 27.00 27.00 27.00 27.00 27.00 27.00 27.00 27.00 27.00 27.00 27.00 27.00 324.00 1112005 1 CCU ASSY 120V, WBACKU S4.5D 4.50 4.50 4.50 4.50 4.50 4.50 4.50 4.50 4.50 4.50 4.50 4.50 54.00 4/12000 25 CCU ASSY 120V. WBACKU $4.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 112.50 1,350.00 9/1/1999 45 CCU ASSY 12DV, WBACKU $4.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 202.50 2,430.00 6/1/1997 50 ASSY,CCU,120V W1 BACK $4.50 225.00 225.00 225.00 225.00 225.00 225.00 225.00 225.00 225.00 225.00 225.00 225.DD 2,700.00 1/12001 14 CCU ASSY 120V, WBACKU $4.50 63.00 63.00 63.00 63.00 63.00 6300 63.00 63.00 63.00 63.00 63.00 63.00 756.D0 Sum 2.434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 2,434.50 29,214.00 Software 5/1/1997 1 SWUC,GU1A,V2.0.7.D004 G $50D.00 500.00 50000 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 6,000.00 Sum 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 500.00 6,000.00 Grand Total 1,934.50 1,934.50 $934.50 2,934.50 2,934.50 2,934.50 2,930.50 1,934.50 2,934.50 2,934.50 1,934.50 $934.50 35,214.00 THIS IS NOT AN INVOICE Tuesday, September 27, 2005 Page 1 of 1 IT) System Support Pricing frin GEORGETOWN, CITY OF (TX) a osnp.IdrTNar Customer Number. 46518 Install Dare Qp, Description Rate Per Uau Jen -06 Feb -06 Mar -06 Apr -06 May -06 Jun -06 JW -06 Aug -00 Sep -06 Hardware 378.00 4,536.00 34.00 34.00 34.00 102.00 33.00 33.00 33.00 396.00 5/12002 1 TRX,G5 TOP LEVEL,RADIO $35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 2/12002 1 TRX,G5R TOP LEVEL $41.58 41.58 41.58 41.56 41.56 41.58 41.58 41.58 41.58 41.58 11/12002 1 TRX,G5 TOP LEVEL,RADIO $35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 35.64 10/12003 1 DCU4 MOBILE COLLECTIO $378.00 378.00 378.00 378.00 378.00 378.00 378.00 378.00 378.00 378.00 10/12005 1 FC2,RAPTOR,128MB,53KEY $34.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 7/12004 1 TRX,G5.TOP LEVEL,RADIO $33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 Sum 523.86 523.86 523.86 523.86 523.86 523,86 523.86 523.66 52386 Software 2112002 1 OBS MVRS,V5.02,POLLING $180.36 180.36 la0.36 180.36 180.36 180.36 180.36 180.36 180.36 180.36 2/12002 1 MAMR,MVRS $190.08 190.08 190.08 190.08 190.08 190.08 190.08 190.08 190.08 190.08 Sum 37044 370.44 37044 370.44 370.44, 37044 370.44 370.44 370.44 Grand Total 994.30 894.30 894.30 894.30 894.30 89430 894.30 894.30 89430 Oct -06 Nov -06 Dec -06 Total 35.64 35.64 35.64 427.68 41.58 41.58 41.58 498.96 35.64 36.64 35.64 427.68 378.00 378.00 378.00 4,536.00 34.00 34.00 34.00 102.00 33.00 33.00 33.00 396.00 557.86 557.86 557.86 6,388.32 180.36 180.36 180.36 2,164.32 190.08 180.08 190.08 2,280.96 370.44 370.44 370.44 4,445.28 928.30 928.30 928.30 10,833.60 THIS IS NOTANINVOICE Tuesday, September 27, 2005 Papa 1 M 1 Council Meeting Date: November 22.2005 Item No. AGENDA ITEM COVER SHEET SUBJECT: Consideration and possible action to authorize a Boundary Line Agreement with the Steenken Family Partnership to establish the common boundary line of City -owned property located at 816 S. Main Street (Fire Department) and the adjoining property to the north located at 812 S. Main Street and currently owned by The Steenken Family Partnership. ITEM SUMMARY: The property adjacent to the north of the downtown Fire Station currently owned by The Steenken Family Partnership and located at 812 S. Main is under contract for sale. In its title examination, Georgetown Title Company discovered a discrepancy in the common boundary line between the two properties indicating an approximate 1.5 -foot discrepancy/overlap of the property boundaries. An in-depth examination of the chains of title to both properties has not revealed a definitive conclusion as to the record title of the subject 1.5 -foot area. Therefore, Georgetown Title is requiring a boundary line agreement between the City and The Steenken Family Partnership in order to insure title. The current property owner, The Steenken Family Partnership, is requesting the City s approval of the attached Boundary Line Agreement, since its existing building actually occupies the 1.5 -foot area of discrepancy. SPECIAL CONSIDERATIONS: None FINANCIAL IMPACT: None GUS BOARD RECOMMENDATION: N/A STAFF RECOMMENDATION: Recommend approval. ATTACHMENTS: Proposed Boundary Line Agreement Submitted By: Patricia E. Carls, Brown & Carls, LLP, City BOUNDARY LINE AGREEMENT STATE OF TEXAS § § KNOW ALL MEN BY THESE PRESENTS: COUNTY OF WILLIAMSON § THIS AGREEMENT is made this day of , 2005, by and between The Steenken Family Partnership, whose address is 114 Ridge Oak Drive, Georgetown, Texas, 78628 (hereinafter "Steenken Family") and the City of Georgetown, a Texas home -rule municipal corporation (hereinafter "City) for purposes of establishing and determining the exact location of the common boundary line between two adjoining tracts of land, one of which is owned by the Steenken Family and the other by the City, in order to eliminate the present existing doubt and uncertainty about the location of the land resulting from possible conflicting or overlapping descriptions in various conveyances recorded in the Official Records of Williamson County, Texas The tracts affected are: (1) Steenken Family Tract: A part of Lots 4 and 5, Block 51, ORIGINAL TOWNSITE OF CITY OF GEORGETOWN, according to the map or plat thereof recorded in Cabinet 5, Slide 211, Official Records, Williamson County, Texas, and further described as "First and Second Tract" in deed to the Steenken Family in Exhibit "F" in Volume 1853, Page 421, Official Records, Williamson County, Texas, as described on "Exhibit A" attached hereto; and (2) City Tract: A part of Lot 5, Block 51, ORIGINAL TOWNSITE OF CITY OF GEORGETOWN, according to the map or plat thereof recorded in Cabinet 5, Slide 211, Official Records, Williamson County, Texas, and further described in deed to the City in Volume 412, Page 95, Official Records, Williamson County, Texas. The common boundary line between these two tracts is the one herein established and agreed upon. It is hereby agreed by the Steenken Family and the City that the common boundary line separating the two tracts described above on the south side of the Steenken Family Tract and the north side of the City Tract shall hereafter be established, located and determined as described by metes and bounds on "Exhibit A" and plat attached hereto and incorporated herein by reference. This agreement establishing the common boundary line above described shall be a covenant running with the land as to each of the adjoining tracts above described and shall be binding on the Steenken Family and their heirs, executors, administrators and assigns, and the City, and its successors and assigns. Boundary Line Agreement — Steenken Family & City of Georgetown Page 1 of 3 EXECUTED in duplicate this day of November, 2005. THE STEENKEN FAMILY PARTNERSHIP 0 Bessie L. Steenken Kent L. Steenken Penny G. Steenken CITY OF GEORGETOWN, a Texas home -rule municipal corporation Un ATTEST: Sandra D. Lee, City Secretary STATE OF TEXAS § COUNTY OF WILLIAMSON § Gary Nelon, Mayor This instrument was acknowledged before me on this the _ day of 2005, by Bessie L. Steenken, Partner, The Steenken Family Partnership. Notary Public, State of Texas Boundary Line Agreement — Steenken Family & City of Georgetown Page 2 of 3 STATE OF TEXAS COUNTY OF WILLIAMSON This instrument was acknowledged before me on this the_ day of 2005, by Kent L. Steenken, Partner, The Steenken Family Partnership. Notary Public, State of Texas STATE OF TEXAS COUNTY OF WILLIAMSON This instrument was acknowledged before me on this the day of 2005, by Penny G. Steenken, Partner, The Steenken Family Partnership. Notary Public, State of Texas STATE OF TEXAS COUNTY OF WILLIAMSON This instrument was acknowledged before me on this the _ day of 2005, by Gary Nelon in his capacity as Mayor of the City of Georgetown, Texas, a Texas home - rule municipal corporation, on behalf of said corporation. Notary Public, State of Texas APPROVED AS TO FORM: Patricia E. Carls, Brown & Carls, LLP City Attorney AFTER RECORDING, RETURN TO: City of Georgetown City Secretary P.O. Box 409 Georgetown, Texas 78627 Boundary Line Agreement — Steenken Family & City of Georgetown Page 3 of 3 CRICHTON AND ASSOCIATES, INC. LAND SURVEYORS 107 NORTH LAMPASAS ROUND ROCK, TEXAS 512-244-3395 FIELD NOTES FIELD NOTES FOR A 504 SQUARE FOOT TRACT OF LAND BEING A PART OF LOTS 4 AND 5, BLOCK 51, OF THE CITY OF GEORGETOWN BEING THE SAME TRACT CONVEYED TO STEENKEN AND DESCRIBED IN EXHIBIT "F" IN VOL. 1853, PG. 421, OFFICIAL RECORDS, WILLIAMSON COUNTY, TEXAS, AND BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS BEGINNING at the East common comer of buildings located at 810 and 812 S. Main Street and being on the West R.O.W. line of South Main Street, from which a building comer being the Northeast comer of said Lot 4, beats N 00° 00' 00" E, 99.82 feet Said building comer being the Southeast comer of a 412 square foot tract conveyed to Lucille Mattocks in Vol. 1652, Pg. 869, Deed Records, Williamson County, Texas, the Northeast comer of this tract, and the POIN 40F BEGINNING. THENCE S 000 00' 00" E, with the West R.O.W. line of South Main Street, 21.75 feet to the Southeast comer of said building located at 812 South Main Street, being the Northeast comer of the remainder of a tract conveyed to the City of Georgetown in Vol. 412, Pg. 95, Deed Records, Williamson County, Texas, also being the Southeast comer of this tract THENCE S 90° 00' 00" W, with the South line of the said building, and the North face of a 1.5' wide brick wall, being the North line of the said City of Georgetown remainder tract, 23.14 feet to the Southwest comer of the said building, being the Southwest comer of this tract and the Southeast corner of a 0.0851 acre tract conveyed to Broussard whose recording data is unknown. THENCE N 000 00' 00" W, with the West face of the said building and the East line of the said Broussard tract, 21.75 feet to the Northwest comer of the said building, for the Northwest corner of this tract. THENCE N 90° 00' 00" E, with the North face of the said building, at 1.5 feet pass the Southwest comer of the said Mattocks tract, in all a total distance of 23.16 feet to the POINT OF BEGINNING and containing 504 square feet of land more or less. I hereby certify that the foregoing field notes were prepared from a survey on the ground under my supervision and are true and correct to the best of my knowledge and belief. Witness my hand and seal October 27, 2005. And revised November 4, 2005 Edward W. Bpdfipld,R.. vV Plot of aurvw N proPeNy at812 South big, described o9 bM 1 • oc4—_, of Volume/6wk/CaNnct f Poaefal/ylde(61 a wbdWWen e/ raeerd M Map or PIN Ceunly rete. pAl Rewrde. O.i. g7T 1 0l Mc TUAmsoa Rel: yelentin SaPohw Dofidl 0 4 5. 2005 6CALi: 1• • 20' WEST 8TH STREET ---r - - - - - - I � I I LOT 3 I LOT i 4 I Is. SURVEY OF I I I A 504 SQUARE FOOT I I I TRACT OF LAND BEING A PART OF LOTS 4 AND 5, BLOCK 51, OF I THE CITY OF GEOREGTOWN, AND I BROUSSARD JO ELLA I I BEING THE SAME TRACT I 0.0851 ACRES CONVEYED TO I I STEENKEN AND DESCRIBED IN EXHIBIT I I$ "F" IN VOL. 1853, PG. I 1gj 421, OFFICIAL I L STO TMAIN IT� RECORDS, WILLIAMSON I MATTOCKS COUNTY, TEXAS I 412SO FT 1652/869 I s' �90"OO &1E P.O.O. I .16 4 Is 1 Is «8 612 g«f S MAIN a9.al Iepn CITY OF GEORGETOWN S90100.001W REMAINDER TRACT 23.18 412/95 (WEST 27.16) C(*IC onnm LOT 6 LOT 5 TO: DeanetOM TIMI COMPlny Inc.A litonsart TIU6 Guaranty Cow f - W W Cr F Z Q H O N eleiueMry. The unchm"Nim "d dew handy worry MN W Ih aheem ..prsaenfa Nes rnwNs N a sarwy w Ms ground under my .uParvlelw and r Nue and fDOVANOImp and That Men an no, Almmi enctes, conflicts, shortages A ane, boundary Xes owlgel, naowhmpfi, d ads ng of Impreveernfi, rNi61e uMINy wumsMs, wept w shorn and Me properly Ips eeeow to and from a dedicated raadray. The property been hewn is located M Eem —2' 0044 outside the 500 Poor Rendall^_ as ween w Gemmunlry Panel Number eaeaw RAU410 G of the FLOOD INSURANCE RATE MAP prepared I. Cit of Geer t by the Fedlrol Insurance AdminlNraNan Dpartmert, N.Y.D. ElfaeMe Dalen Best. This Information te based m4ly on mid mp and the au oyer claw net assume nap muhnny w lI arty IntamNlen pmWed and does nN represent accuracy ar Inwparaay N mid map This surv•9' is OZYTrr 2004 by Crichton and Awckha. Inc., and le being p—Woo sale for Rha uaa el the curtaf Ream• has been poNfia and no crested, express a Imodw. to espy Py_wp Rha aurwy except es N none., In conjunction TIM this lranwa en sly, ENO • Vr nal rs Meso cRICHTON P K` .� OF *`'� T 6a eWE AND gSSOC/AYES /NC. $ m VE ur W BP j�j,p •LAND SURVEYORS =GAuISr ' 1 sun o TK 91vY iYOI NINp9 107 N. LAMPASAS STREET 'R-En VINCE ROUND ROCK, TEXAS 78664—�.--a�awl Inartxa (512) 244-0895—s—.—wr rpra FAX 512 244-9608 c—r—owaann A Ma REMOE, 1 I K) KnIO WpYAIIM EN • 'No . VISN: Nov. 4; No.. 1, 2005 DATt PCt. T. 9996 Council Meeting Date: November 22, 2005 Item No. M o� AGENDA ITEM COVER SHEET SUBJECT: Consideration and possible action to renew the contract between the City of Georgetown and ElectSolve Technology Solutions and Services Incorporated to provide AMR System Data Services in an amount not to exceed $77,600.00. ITEM SUMMARY: In December 2001 the Georgetown City Council approved the contract for AMR data services between ElectSolve Technology Solutions and Services Incorporated and the City of Georgetown. This contract is a five-year contract, renewable annually upon the agreement of both entities. This year, the City and ElectSolve have agreed to renew the contract from January 2006 through December 2006. Renewal of this contract will allow the City to continue to streamline and further automate data gathering and reporting, as well as maintain the current 24 hour a day, 7 days a week customer support. SPECIAL CONSIDERATIONS: All employees of ElectSolve Technology Solutions and Services Incorporated have passed background checks per requirements of Georgetown Utility Systems. FINANCIAL IMPACT: Funds not to exceed the amount of $77,600.00 will be taken from the AMR and Electric operations accounts 610-115-5303-00 & 610-106-5602-00. GUS BOARD RECOMMENDATION: The GUS Board recommended approval at the November 15, 2005 meeting. Approved 5-0. Young and Brown absent. STAFF RECOMMENDATION: The Staff recommends approval of the renewal of the AMR System Data Services contract. COMMENTS: None ATTACHMENTS: 1. Letter of agreement for contract extension from ElectSolve. 2. Fourth Amendment to Professional Services Agreement with ElectSolve Submitted By: �4ike Mayben, v J' Brig Energy Services Manager ssistan ty anager for Utilities Tec hnoledy Solutions and Sarrlces. Inc. P.O. Box 661 Shreveport, La. 71162 Walter: 11/8/05 The Georgetown AMR Support Agreement is nearing completion for the calendar year of 2005. ElectSolve Technology Solutions and Services, Inc. wishes to renew this agreement with the City of Georgetown for the calendar year 2006 as allowed within the terms of the contract. We believe that we can continue to provide value by delivering a premium support service and continuing to enhance this system during the coming year. The 2006 monthly support and system enhancement fees will be $4800.00 per month. During 2005 in addition to providing 24x7 technical system support, consulting and on-site solution management, ElectSolve continued to enhance and streamline meter reading system processes to maximize efficiencies and to increase overall systems reliability. During 2006, ElectSolve will continue to identify and recommend changes and enhancements that will increase the overall effectiveness and applicability of all meter reading technologies currently deployed and supported at the City of Georgetown. We feel that there will continue to be areas that can be improved and streamlined, enabling the City of Georgetown to continue to expand the effectiveness of its' AMR meter reading investments going forward. 1 ElectSolve feels that these investments will continue to return value to the City of Georgetown as long as they are properly maintained and enhanced on an ongoing basis. ElectSolve plans to continue its' commitment to the City of Georgetown and to provide the absolute best service it can possibly provide. Z�; - 112 Ma Ponder Chief Technologist/Managing Director ElectSolve Technology Solutions and Services, Inc. mponder@electsolve.com 318-347-4305 Cell 318-752-1500 318-949-8885 Fax THE STATE OF TEXAS § FOURTH AMENDMENT TO § PROFESSIONAL SERVICES COUNTY OF WILLIAMSON § AGREEMENT WITH § ELECTSOLVE TECHNOLOGY CITY OF GEORGETOWN § SOLUTIONS AND SERVICES, INC. THIS IS THE FOURTH AMENDMENT TO THE PROFESSIONAL SERVICES AGREEMENT by and between the City of Georgetown, a Texas home -rule municipal corporation ("City") and ElectSolve Technology Solutions and Services, Inc., a Louisiana corporation ("ElectSolve") (each a "Party" and, collectively, the "Parties'). WHEREAS, the City and ElectSolve entered into a certain "Professional Services Agreement with ElectoSolve Technology Solutions and Services, Inc." ("Agreement") on January 1, 2002, whereby the City employed ElectSolve to provide operations services for the City's Automatic Meter Reading System ("AMR Operation Services"); and WHEREAS, the Parties agreed to a renewal provision in which the Parties can renew the Agreement for up to four (4) terms beyond the original term, upon the mutual written consent of the Parties; and WHEREAS, the Parties have mutually agreed to renew the Agreement for the third term of the Agreement, the 2006 calendar year, to be effective January 1, 2006, as follows: NOW THEREFORE, for and in consideration of the promises and mutual agreements set forth herein, the City and ElectSolve agree as follows: Section 1.1 of the Agreement is hereby amended to provide as follows: 1.1 TERM. This Agreement shall be in effect for a period o2 one (1) year commencing on January 1, 2006 and ending on December 31, 2006 (the "Term"). 2. Exhibit "A" of the Agreement, being the scope of services and payment terms, is hereby amended to provide as follows: ElectSolve will provide Professional Services to support and maintain existing AMR systems integration applications and procedures implemented by DataPult during the integration phase of the Georgetown Utility System ("GUS") AMR project. This Base Fixed Support Agreement will provide for minimum required support services to enable and assist GUS staff to manage and operate the AMR data systems necessary to produce billing files to their existing CIS (Customer Information System). Additionally this proposal provides GUS an AMR Operations Services Agreement — Fourth Amendment ElectSolve Technology Solutions and Services, Inc. Page 1 of 4 hourly service option for professional services exceeding the coverage of the minimum Base Fixed Support Agreement to use at their convenience of other related I/T projects and maintenance services. Solution Price ElectSolve annual AMR data integration systems software $4,800.00 per and hardware support and maintenance agreement for the month, period January 1, 2006 through December 31, 2006. but not to exceed $77,600 Includes: AMR network support, AMR hardware support, for the contract Oracle database maintenance and support, support and year continuous enhancements to: TUI, Impact, MVRS-Translator and Integration Oracle Schema, Maintenance and backups for both Oracle databases, 240 phone support, 12 hours minimum on-site per month, 6 hour response on-site for critical failures as required. 2. Miscellaneous. Except as expressly modified by this Third Amendment, the Agreement remains unchanged and in full force and effect. All capitalized terms used herein and not otherwise defined shall have the same meaning ascribed to them in the Agreement. This Fourth Amendment may be executed in multiple counterparts, each of which shall be deemed an original. SIGNED this day of 12005. CITY OF GEORGETOWN, TEXAS ELECTSOLVE TECHNOLOGY SOLUTIONS AND SERVICES, INC. 0 Gary Nelon, Mayor ATTEST: Sandra D. Lee, City Secretary APPROVED AS TO FORM: By gark Ponder Chief Technologist/Managing Director AMR Operations Services Agreement — Fourth Amendment ElectSolve Technology Solutions and Services, Inc. Page 2 of 4 Patricia E. Carls, City Attorney AMR Operations Services Agreement — Fourth Amendment ElectSolve Technology Solutions and Services, Inc. Page 3 of 4 STATE OF TEXAS § ACKNOWLEDGMENT COUNTY OF WILLIAMSON § This instrument was acknowledged before me on this the day of , 2005, by Gary Nelon, a person known to me, in his capacity as Mayor of the City of Georgetown, a Texas Home Rule Municipal Corporation, on behalf of the City of Georgetown. Notary Public in and for the State of Texas STATE OF TEXAS ACKNOWLEDGMENT COUNTY OF WILLIAMSON This instrument was acknowledged before me on this the L day of 2005, by `1'110. k rc of Electsolve Technology Solutions and Services, Inc., a Louisiana corporation, on behalf of said corporation. TERI VALLEY No 1c ' and for the State of Te rp(1ARIXt IfA 1#01,th! COMIIAIO!lANIU' S[PTOOR 10, 200 AMR Operations Services Agreement — Fourth Amendment ElectSolve Technology Solutions and Services, Inc. Page 4 of 4 Agenda Item Check List &Mffm Financial Impact Agenda Item: AMR System Data Services Agenda Item Subject: Renewal of AMR System data services with ElectSolve Is this a Capital Improvement _? Yes 9 No Project: Council Date: 11/22/2005 link to Agenda database => qb Need Help? Was it budgeted? • Yes O No Is it within the approved budgeted amount? • Yes C? No If not, where is the money coming from? G/L Account Number 610 -115 -5303 -AM $57,600 610-106-5602-00 $20,000 Amount Going to Council $ 77,600.00 Is there something (budgeted) that won't get Yes • No done because you are spending these funds? If so, please explain. Will this have an impact on the next year's Yes • No budget? If so, please explain. Does this project have future revenue Yes * No impact? Year: Department: If so, how? Identify all on-going costs (i.e., insurance, annual maintenance fees, licenses, operational costs, etc...). Estimated staff hours: Cross -divisional impact: Yes 0 No If so, what division(s)? Prepared by: Walter Koopmann Date: 11/08/2005 Agenda Item Checklist:Approved on 1110812005 Approvers Title[Assigned Notified Received tatus Changed Status Jim Briggs Assistant City 11/08/2005 11/08/2005 11/08/2005 11/08/2005 Approved Jose Lara Manager 11/08/2005 11/08/2005 11/08/2005 11/08/2005 Approved Utility Financial Analyst Approval Cycle Settings Council Meeting Date: November 22, 2005 Item No. _I AGENDA ITEM COVER SHEET SUBTECT: Consideration and possible action to approve a contract amendment between the City of Georgetown and Kasberg, Parker & Associates for professional services related to the design of the Phase III EARZ remediation in the amount of $61,600.00. ITEM SUMMARY: Chapter 213 — Edwards Aquifer Recharge Zone (EARZ) rules of the TAC requires the testing of wastewater collection system mains, 6" and larger in diameter, to locate structural damage and defects that potentially pose a threat to the Edwards Aquifer, once every five years. The final report of the third phase of testing was submitted by GSW W to the City onAugust 2005. The report identified 224 total system flaws consisting of both infiltration (water leakage into system) and exfiltration (water leakage out of system). Although GUS intends to repair all flaws in a timely manner, the Chapter 213 rules require that all exfiltration flaws must be repaired within 12 months of the date reported. This item provides for the engineering services related to all of the exfdtraticn defects found during the third phase of EARZ testing. The total cost for engineering services is $61,600.00. SPECIAL CONSIDERATIONS: None. FINANCIAL IMPACT: Funds will come from the Wastewater Capital Fund 651101-6618-00. GUS BOARD RECOMMENDATION: GUS Board recommended approval at the November 15, 2005 meeting. Approved 5-0. Young and Brown absent STAFF RECOMMENDATION: Staff recommends the contract amendment for engineering services by KPA. COMMENTS: None. ATTACHMENTS: Proposal for Parker & Submitted by: 'Glenn W. Dishong, Water Services Manager �Assistants' ager for Utilities AMENDMENT DATED NOVEMBER 1, 2005 TO THE AGREEMENT BETWEEN THE CITY OF GEORGETOWN AND KASBERG, PATRICK & ASSOCIATES, L.L.P. FOR PROFESSIONAL SERVICES FOR EDWARDS AQUIFER RECHARGE ZONE WASTEWATER REHABILITATION PHASE III The General Services Agreement between the CITY OF GEORGETOWN (City) and Kasberg, Patrick & Associates, L.L.P., (Engineer) last authorized on March 14, 1995, is hereby amended as follows: The scope and cost of the anticipated services are set forth in the attached Exhibit A. The charges for the work in Amendment dated November 1, 2005 are to be paid on a lump sum basis unless additional work due to change in scope is authorized. Your signatures below will constitute your acceptance of Amendment dated November 1, 2005. Executed in duplicate original this day of 2005 at Georgetown, Texas, where this contract is performable and enforceable. Approved as to form: Patricia E. Carls City Attorney Party of the First Part: CITY OF GEORGETOWN, TEXAS Gary Nelon Mayor Attest: Sandra D. Lee Party of the Second Part: City Secretary KASBERG, PATRICK & ASSOCIATES, L.L.P. By: R. David Patrick, P.E. Principal Engineer STATE OF TEXAS COUNTY OF BELL This instrument as acknowledged before me on this the i s+- day of V oV4. Lwj( 2005. Notary Public +..o+ DORIS M. WALTERS Notary PUbI�, state Of Texas $....._ My commission Explres December 27, 2005 Printed name: DDR+S M. VJAL'rLRg Commission Expires: 12- A*7- 0 5 Exhibit A (Updated November 1, 2005) This updated Exhibit A to the original General Services Agreement between the City of Georgetown and Kasberg, Patrick & Associates, L.L.P., dated March 14, 1995, provides for the scope of engineering services required for developing design for the Edwards Aquifer Recharge Zone Wastewater Rehabilitation Phase III. The attached letter details the services and associated charges for the proposed work. KASBERG, PATRICK & ASSOCIATES, L.L.P. ICA CONSULTING ENGINEERS One South Main Temple, Texas 76501 (254) 773-3731 Fax (254) 773-6667 mail@kpaengineers.com RICK N. KASBERG, P.E. R. DAVID PATRICK, P.E. November 1, 2005 Mr. Jim Briggs Assistant City Manager City of Georgetown P.O. Box 409 Georgetown, Texas 78627-0409 Re: City of Georgetown Proposal for Edwards Aquifer Recharge Zone Wastewater Rehabilitation Phase III Georgetown, Texas Dear Mr. Briggs: This letter proposal is in response to your request for basic and special engineering services required to provide construction drawings for wastewater improvements for: The Edwards Aquifer Recharge Zone Wastewater Rehabilitation Phase III The charges for this work are shown on Attachment "A" of this letter. We have priced the work according to the facts that we know about the project as of this date. Lump Sum charges are shown and will not change unless the scope of work is expanded, at which time we will meet with you and plan accordingly. The following are tasks that we have included in the work schedule: PRELIMINARY ENGINEERING PHASE. This phase involves determination of project scope and economic and technical evaluation of feasible alternatives. Services during this phase include: 1. Obtaining and reviewing available data and consulting with the City to clarify and define the CITY's requirements for the project. 2. Advising the CITY as to the necessity of providing or obtaining from others additional data or services. These additional services may include photogrammetry, investigations and consultations, compilation of hydrological data, traffic studies, materials engineering, assembly of zoning, deed, and other restrictive land use information, and environmental assessments and impact statements. Mr. Jim Briggs November 1, 2005 Page Two 3. Identifying and analyzing requirements of governmental authorities having jurisdiction to approve the design of the project, and participating in consultations with such authorities. 4. Providing analyses of the CITY's needs, planning surveys, and comparative evaluations of prospective sites and solutions. 5. Providing a general economic analysis of the CITY's requirements applicable to various alternatives. 6. Consulting with the CITY, reviewing preliminary reports, clarifying and defining the project requirements, reviewing available data, and discussing general scheduling. Conferences may also be required with approving and regulatory governmental agencies and affected utilities. 7. Advising the CITY as to whether additional data or services are required, and assisting the CITY in obtaining such data and services. 8. Obtain plans and information on facilities that have been updated after analysis of the wastewater system. 9. Assist the City of Georgetown in recordkeeping issues associated with the EARZ Program. 10. Analyze the existing utilities and incorporate into the preliminary plan. FINAL DESIGN PHASE. This phase of project development is undertaken only after the CITY has approved the preliminary engineering phase material. The basic services for the final design phase includes: 1. Preparing construction drawings and specifications showing the character and extent of the project based on the accepted preliminary engineering documents. 2. Preparing and furnishing to the CITY a revised opinion of probable costs based on the final drawings and specifications. 3. Furnishing the necessary engineering data required to apply for regulatory permits from local, state, or federal authorities. This is distinguished from and does not include detailed applications and supporting documents for government grant-in-aid or planning grants that would be furnished as additional services. Fees for any local, state or federal construction permit applications are not included as part of the professional fee charges. These will be paid by the CITY. Mr. Jim Briggs November 1, 2005 Page Three 4. Preparing basic documents related to construction contracts for review and approval by the CITY (and the CITY's legal and other advisors). These may include contract agreement forms, general conditions and supplementary conditions, invitations to bid, instructions to bidders, insurance and bonding requirements, and preparation of other contract -related documents. 5. Furnishing to the CITY the specified number of copies of drawings, specifications, and other contract documents. 6. Meet regularly with the City of Georgetown Staff to review the progress of the design and coordinate any conflicts that arise. BIDDING PHASE. (If Required) Services under this phase include: 1. Assisting the CITY in advertising for and obtaining bids for each separate prime construction contract, maintaining a record of prospective bidders to whom bidding documents have been issued, attending pre-bid conferences, and receiving and processing fees for bidding documents. 2. Issuing addenda as appropriate to interpret, clarify or expand the bidding documents. 3. Assisting the CITY in determining the qualifications and acceptability of prospective constructors, subcontractors and suppliers. 4. When substitution prior to the award of contracts is allowed by the bidding documents, consultation with and advising the CITY as to the acceptability of alternate materials and equipment proposed by the prospective constructors. 5. Attending the bid openings, preparing bid tabulation sheets and providing assistance to the CITY in evaluating bids or proposals and in assembling and awarding contracts for construction, materials, equipment and services. Mr. Jim Briggs November 1, 2005 Page Four CONSTRUCTION PHASE. Services under this phase involve consulting with and advising the CITY during construction and are limited to those services associated with performing as the CITY's representative. Such services comprise: 1. Preparing for and conducting a pre -construction conference and issuing a Notice to Proceed on behalf of the CITY. 2. Reviewing shop and erection drawings submitted by the constructors for compliance with design concept. 3. Reviewing laboratory, shop and mill test reports on materials and equipment. 4. Visiting the project site weekly as construction proceeds to observe and report on the progress and the quality of the executed work. 5. Issuing necessary interpretations and clarifications of contract documents, preparing change orders requiring special inspections and testing of the work, and making recommendations as to the acceptability of the work. 6. Preparing sketches required to resolve problems due to actual field conditions encountered. 7. Preparing record drawings from information submitted by the CONTRACTOR. SPECIFIC INFRASTRUCTURE DESIGN FEATURES FOR THE PROJECT • Research of existing facilities • Research of existing utilities • Research of existing wastewater system • Review and recommendation of probable rehabilitation methods • Research and verification of defect locations, easements, right-of-way etc. • Contract Documents and Specifications • Project to be bid and contracted • Construction Administration • Construction Staking • As -built drawings delivered to the City of Georgetown in both hard and electronic format • Certify results to the TCEQ Mr. Jim Briggs November 1, 2005 Page Five GEOTECHNICAL INVESTIGATION. Geotechnical investigations will not be provided by KPA under this contract. If this proposal is agreeable, please return an executed original to our office. Sincerely, R. David Patrick, P.E. RDP/crc ATTACHMENT A SUMMARY OF CHARGES FOR SERVICES 2005— 2006 CAPITAL IMPROVEMENTS PROJECT FOR THE EDWARDS AQUIFER RECHARGE ZONE WASTEWATER REHABILITATION PHASE III GEORGETOWN, TEXAS TASK Edwards Aquifer Recharge Zone Wastewater Rehabilitation Phase III I. BASIC SERVICES A. Preliminary Engineering $ 9,700.00 B. Final Design Phase $ 18,500.00 C. Bidding $ 5,000.00 D. Construction Administration $ 16,000.00 TOTAL BASIC SERVICES $ 49,200.00 II. SPECIAL SERVICES A. Project Surveys $ 9,900.00 B. TCEQ Submittals $ 2,500.00 TOTAL SPECIAL SERVICES $ 12,400.00 Agenda Item: Agenda Item Check List ismom Financial Impact EARZ Phase III Repairs (ENG) Agenda Item Subject: Consideration and possible recommendation to approve a contract amendment between the City of Georgetown and Kasberg, Parker & Associates for professional services related to the design of the Phase III EARZ remediation in the amount of $61,600.00. Is this a Capital Improvement • Yes No Project: Council Date: 11/22/2005 link to Agenda database => Need Help? Was it budgeted? 0 Yes ! l No Is it within the approved budgeted amount? • Yes No If not, where is the money coming from? G/L Account Number 651-101-6618-00 Amount Going to Council $ 61,600.00 Is there something (budgeted) that won't get Yes 0 No done because you are spending these funds? If so, please explain. Will this have an impact on the next year's Yes 10 No budget? If so, please explain. Does this project have future revenue Yes 0 No impact? Year: Department: If so, how? Identify all on-going costs (i.e., insurance, annual maintenance fees, licenses, operational costs, etc...). Estimated staff hours: Cross -divisional impact: Yes 0 No If so, what division(s)? Prepared by: Glenn DishongDate: 11/15/2005 Agenda Item Checklist: Approved on 11/16/2005 pprovers itle Assigned Notified eceived Latus Changed Status Jim Briy s Assistant City 11/15/2005 11/15/2005 1/16/2005 11/16/2005 Approved Jose Lara Manager 11/16/2005 11/16/2005 1/16/2005 1 V16/2005 Approved Utility Financial Analyst Approval Cycle Settings Council Meeting Date: November 22, 2005 Item No. AGENDA ITEM COVER SHEET SUBJECT: Consideration and possible action to approve a contract between the City of Georgetown and GSWW, Inc for engineering services related to the fourth phase of the Edwards Aquifer Recharge Zone testing program and approve a budget of $74,730.00. ITEM SUMMARY: Chapter 213 — Edwards Aquifer rules of the TAC requires communities to test their wastewater collection system mains, 6" and larger in diameter, to locate structural damage and defects that potentially pose a threat to the Edwards Aquifer, once every five years. The TCEQ authorized the City to implement its testing program over an eight-year period. Georgetown Utility Systems has contracted with GSW W, Inc. to perform sewage collection system testing and evaluation. GSW W completed the third phase of testing and the staff is pursuing rehabilitation of the defects that were identified. This item provides for the fourth year of testing. This phase of testing will result in the inspection of 125,000 feet of collection mains. The area to be tested will be portions of River Bend, Oak Crest, and Old Town. The project budget is $74,730.00. SPECIAL CONSIDERATIONS: None. FINANCIAL IMPACT: Funds for this project will come from the Wastewater Capital Fund 651-101-6618-00. GUS BOARD RECOMMENDATION: GUS Board recommended approval at the November 15, 2005 meeting. Approved 5-0. Brown and Young absent STAFF RECOMMENDATION: Staff recommends contract amendment for engineering services by GSW W. COMMENTS: None. ATTACHMENTS: Engineering Submitted By: Glenn W. Dishong, Jim Water Services Manager for Utilities �I I ,. TTI� DATE: TO: FROM: PROJECT: GSWW, Inc. CiviUEnvironmental Engineers, Planners Dallas. Fort Worth. Midland. Austin Predecessor Firms: Gutierrez, Smouse, Wilmut & Assoc., Inc. Washington & Associates, Inc. PROPOSAL FOR ENGINEERING SERVICES November 9, 2005 The City of Georgetown, Texas 609 Main Street Georgetown, Texas 78627-0409 GSWW, Inc. 1016 Mopac Circle, Suite 201 Austin, Texas 78746 Phase 4 Sanitary Sewer Testing - Edwards Aquifer Protection (TAC Chapter 213) City of Georgetown, Texas GSWW, Inc. (ENGINEER) proposes to furnish Engineering Services to the City of Georgetown, Texas (OWNER) for a Multi -Year Program designed to achieve compliance with the Edwards Aquifer Protection requirements as outlined in Chapter 213 of the Texas Administrative Code. INTRODUCTION The entire wastewater collection system serving the City of Georgetown, Texas will be tested as a portion of this program. The overall program will be completed in eight phases. The program will utilize a variety of methods and procedures with the goal of meeting the requirements of Chapter 213 (Method 4 — Other Methods Approved by the TNRCC Executive Director). Chapter 213 requires certain communities over the Edwards Aquifer Recharge Zone to continuously test their wastewater collection system for potential exfiltration. This proposal covers work planned under Phase 3 (Third year of testing). This phase is designed to provide the information required to comply with the Chapter 213 requirements (i.e., potential exfiltration that could impact the Edwards Aquifer) and to provide the City of Georgetown with additional information regarding the wastewater collection system, such as flow characteristics (i.e., inflow and infiltration entering the collection system), data for GASB 34 and CMOM requirements, and hydraulic modeling efforts. This phase will cover approximately 125,000 linear feet of collection system and 430 manholes will be evaluated. This phase of the overall program, which includes testing, analysis, development of rehabilitation recommendations is projected for completion in seven months. SCOPE OF WORK This project will consist of performance of the following tasks: Task 100 — Preparatory Work and Mobilization Collect and review existing information including reports, maps, flow records, water records, maintenance records and other pertinent information related to this project. 2. Printing of all field forms and preparation of map with numbers assigned to manholes to be used in the project. 1016 Mopac Circle, Suite 201 . Austin, Texas 78746 . 512.306.9266 . 512.306.9550 Fax . www.gsw-inc.com Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 3. Preparation of equipment to be assigned and transported to the project site. 4. Hold a project kick-off meeting prior to commencement of any work to ensure that all work is conducted in the most economic method; with proper liaison among the city personnel, and; following all safety procedures. & Plan for traffic and pedestrian control to ensure public safety and convenience. The compensation for this task will be on a "Lump Sum" basis. Task 200 — Review of Existing Information GSWW will meet with appropriate City of Georgetown personnel and review all available historical information regarding the collection system. This information can include the following data: • Wastewater Masterplan • Historical Wastewater Flow Data • Historical Maintenance Records including System Maintenance Records • Collection System Design Plans, Record Drawings, etc • Historical SSO Records and Disposition This task shall also include the work developed in support of the City of Georgetown's efforts regarding communication and reporting to appropriate regulatory agencies regarding this project. The compensation for this task will be on a "Lump Sum" basis. Task 300 — Public Awareness and Involvement Public involvement regarding this project will be handled at one or more of the following levels as appropriate: • Level 1 — Informational Door Hangers. The ENGINEER shall prepare and distribute door hangers that include brief information regarding the project for the areas where work will be performed during a particular phase of the project. • Level 2 — Letters. The ENGINEER will provide letters from the City of Georgetown outlining the components and goals of the project. The City of Georgetown will distribute these letters as appropriate and/or the ENGINEER will distribute these letters in the same manner described above for Door Hangers. • Level 3 — The ENGINEER will attend public meetings as required for the duration of the project. The necessity of a public meeting will be determined by the City of Georgetown. The compensation for this task will be on a "Lump Sum" basis. Task 400 — Smoke Testing Smoke will be introduced into the sewer system using a high capacity air blower testing two line segments or manhole reaches at a time. The air blower will have a minimum capacity of 4,000 CFM. This harmless and relatively odorless smoke testing will be performed under dry weather conditions to allow the maximum detection of inflow and rainfall responsive infiltration/infiltration sources. This task, as described above, will be employed on the sewer lines within the study area. Aboveground reconnaissance of the study area to determine proximity of storm sewers, creek Phase 4 Gtown Proposal Revt.doc Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 crossings, drainage paths and ponding areas to the sanitary sewer system will be accomplished concurrently with smoke testing and the visual manhole/line inspection. Digital photographs of every smoke leak found will be taken and sketches showing the leak location will be made and attached to the field forms. Smoke testing data collected in the field will include: • Upstream/downstream manhole number • Length of sewer line • Cover over line segment Leak location from two known reference points • Degree of smoke observed • Leak drainage path/pounding area • Storm sewer crossings or cross connections • Classifications of leaks as: -Main line -Manhole -Public service line -Private service line The compensation for this task will be based on a "Per Linear Foot" basis. We estimate approximately 125,000 linear feet will be smoke tested in this Phase. The Utility will be performing smoke testing on approximately 100,000 linear feet of the 125,000 linear feet in the project. Task 500 — Dyed Water Flooding/Leak Ouantification and Evaluation This task consists of pinpointing inflow sources and quantifying selected collection line, manhole and service line leaks that were identified from the results of previous tasks. Quantification estimates are based on field measurements and empirical values developed from past experience. Leak quantification will also be performed by use of portable weirs or hydrostatic devices in conjunction with dye water flooding. This information is then used to evaluate infiltration/exfiltration rates. A portion of the dye flooding will be performed in conjunction with the internal (CCN) inspection. The compensation for this task will be based on a "Per Each" basis. We estimate approximately 10 dyed water tests will be performed in this Phase. Task 600 — Night Flow Isolation This test consists of dividing the major basins into smaller areas (2,000-5,000 L.F.) and taking weir readings during minimum flow periods (11 p.m. — 6 a.m.) to determine if infiltration/exfi@ration sources exist from groundwater require additional investigation. The compensation for this task will be based on a "Per Each" basis. We estimate approximately 20 night flow isolation tests will be performed in this Phase. Task 700 — Closed Circuit Television (CCTV? Internal Inspection This task consists of the CCTV inspection, using closed circuit color television equipment, of the sewer lines cleaned and for location of buried manholes. The CCN inspection will be recorded on videotapes. Concurrent dyed water flooding will be performed with television inspection to verify locations of defects. Field inspection log sheets will be used to document problems and defects discovered during inspection. Phase 4 Gtown Proposal Revt.doc Edward Aquifer Protection Plan City of Georgetown, Texas 11/912005 Television inspection to be performed will be in accordance with the following specifications: 1. All television equipment used shall have at least 250 lines of horizontal resolution. 2. The picture shall be in color. 3. A log sheet, compatible with the tape, must be made noting deficiencies. 4. By voice on the tape, the operator shall: • Note the date and time the recording was made. • Note the name of the company performing the television inspection and the name of • the operator. • Note the location, designation, size of the main and direction in which the test was made. • Identify every 50 -foot station. • Identify the station of each manhole. • Identify the location and station of deficiencies. • Identify the location and direction of entry for laterals. 5. If the test is being run from manhole to manhole, the camera shall move downstream. If the test is being run from manhole to cleanout, the camera shall move upstream. When obstructions are encountered, an attempt will be made to televise the sewer line from both upstream and downstream manholes. The footage to be used for computing payment earned on lines televised will be on the pipe diameter and the following: 1. The actual distance the camera is navigated through the line or one half (1/2) the full length of the line, whichever is greater, for those lines where the camera is navigated from one end of the line only. 2. The full length of those lines, which are inspected from both ends. The CCN inspection data will be presented to the Owner in VHS format and included in the inspection database to be fumished for each phase of the overall project. The compensation for this task will be based on a "Per Linear Foot' basis, where GSW W performs the inspection. We estimate approximately 12,500 linear feet will be inspected in this Phase and the work will be performed by the City. Task 800 — Air Testing This task consists of the performance of an industry standard "Constant Pressure Method" or 'Time Pressure Drop Method" Air Test to determine if the potential for infiltration/exfiltration exists in a particular pipe segment. To perform the test, a section of sewer main is isolated using test plugs. The segment is then filled with air in sufficient quantity to maintain a constant pressure of 3.0 psig. Using the "Constant Pressure Method" the rate of loss of pressure shall be no more than 0.0015 cfm per square foot of internal pipe surface area. Using the "Time Pressure Drop Method", the time to obtain a pressure drop from 3.5 psig to 2.5 psig will be determined using industry accepted methods and in accordance with the methods outlined in the April 1972 Journal of Water Pollution Control Federation criteria for testing sewer pipe installations. The compensation for this task will be based on a "Per Each" basis. Since the air test is generally used for new pipeline installations, compensation will be requested based on the performance of the test, notwithstanding the results of the test. We estimate approximately 10 air tests will be performed in this Phase. Phase 4 Gtown Proposal Revl.doc Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 Task 900 — Deflection Testing This task consists of the performance of an industry standard 5% mandrel test. This test is generally used to test PVC pipelines. The size and configuration of the mandrel is based on the designation of the PVC pipeline being tested. This test is conducted to determine the condition of joints in the pipeline and to test for a uniform cross section in the segment. The compensation for this task will be based on a "Per Each" basis. Since the mandrel test is generally used for new pipeline installations, compensation will be requested based on the performance of the test, notwithstanding the results of the test. We estimate approximately 10 mandrel tests will be performed in this Phase. Task 1000—Infrared Camera Manhole Locations This task consists of the performance of a field inspection using an infrared (IR) camera capable of locating manholes and mainline cleanouts buried under grass, dirt, or various types of pavement. The camera system will locate these system appurtenances to within six inches of their exact location underground. This task will be performed on line segments designated by the City of Georgetown. The compensation for this task will be based on a "Per Linear Foot' basis. We estimate approximately 10,000 linear feet will be tested. Task 1100 — Data Management and Data Entry This task consists of the performance of data management and data entry tasks for data collected by GUS. The data will undergo initial OA/QC procedures, development of "request for information (RFI) to GUS, map updates in GIS, and development of the project database. The compensation for this task will be based on a 'Per AsseVForm" basis. We estimate approximately 1,000 forms will be generated by GUS personnel for this project. Task 1200—Project Administration, Management, Supervision and OA/OC. This task consists of supervision of field personnel, project administration and management, scheduling of field tasks, general management and supervision of field personnel, and quality assurance/control of field work and data management activities. Additionally, it will include: 1. Conduct general administration and periodic meetings as necessary with OWNER. 2. Perform internal project control procedures on a monthly basis including schedule, budget, quality control review and invoices. 3. GSWW will prepare and deliver notices necessary for the performance of smoke testing. Every reasonable effort will be made to distribute notices two (2) days prior to smoke testing in the area. The compensation for this task will be on a "Per Lump Sum" basis. Task 1200—Data Evaluation, Analysis & Report This task consists of evaluating and analyzing the collected data, reviewing videotapes of the CCTV inspection and presenting the results in the form of a report. Two (2) copies of a draft Phase 4 Gtown Proposal Revl.doc 5 Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 report will be prepared for submittal to the OWNER for review and comments including the following: a. Flow data summary results. b. Computer printouts of problems listed by priorities (rehabilitation ranked by cost effectiveness to eliminate 1/1). C. Computer listing of all problems found, including structural and maintenance problems. d. Recommended rehabilitation work grouped and tabulated in three (3) major categories: collection lines; manholes, and; service lines. Service lines will be further categorized as work on public and private property. The tables will provide information necessary for the rehabilitation work to be done including estimated improvement costs. In addition to this listing, the recommended rehabilitation will be categorized by rehabilitation priority. Five (5) copies of the Final Report incorporating the comments from the review of the draft report will be furnished. One original copy of the field reports with photographs along with the VHS videotape recordings of the television inspection of sewer lines will also be furnished. The entire Final Report will be provided to the City in Microsoft Office 2000 format. Updated mapping files will be furnished in ArcView Version 9.0 format. The compensation for this task will be on a "Per Lump Sum' basis. Task 13170 — Training in Field Data Collection, Data Management and Reporting Techniques This task includes classroom and in -field training of up to 10 City of Georgetown personnel with regard to industry standard methods used to collect and manage field data. Training in the development of data reporting and data visualization methods based on the collected field data using GIS, GPS, and Microsoft Access databases. Proposed topics include the following: Smoke Testing Manhole and Pipeline Visual Inspection Sanitary Sewer Cleaning and CCTV Inspection Flow Isolation Dyed Water Testing Deflection Testing The compensation for this task will be based on a as 8 -hours of classroom and field instruction time. be completed during this Phase. III. INDEMNIFICATION ArcView GIS Microsoft Access 2000 Database Crystal Reports Global Position Systems Flow Monitoring Installation/Maintenance Rainfall Gauge Installation/Maintenance "Training Day" basis. A training day is defined We estimate approximately 3 training days will In addition, and notwithstanding any other provisions of the Agreement, the OWNER agrees, to the fullest extent permitted by law, to indemnify and hold harmless the ENGINEER, its officers, directors, employees, and subconsultants, (collectively, ENGINEER) against all damages, liabilities or costs including reasonable attorneys' fees and defense costs, arising out of or in any way connected with this project or the performance by any of the parties above names of the services under this Agreement, excepting only those damages, liabilities, or costs attributable to the negligent acts of negligent failure to act by the ENGINEER. IV. INSURANCE Prior to the commencement of any work, the ENGINEER shall furnish the OWNER with certificates of insurance covering claims arising out of the performance of the Services and caused in whole or part by the errors, omissions, or negligent acts for which the ENGINEER is Phase 4 Gtown Proposal Revt.doc Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 legally liable. Such certificates shall provide that the OWNER receives at least thirty (30) days prior written notice of any material change in, or the cancellation of such insurance. • Workers' Compensation Insurance in accordance with applicable state requirements • Errors and Omissions Insurance with limits not less than $1,000,000.00 combined single limit • Business Automobile Liability Insurance for all owned, non -owned, and hired vehicles with a minimum combined limit of $500,000.00 per occurrence for bodily injury and property damage. V. COMPENSATION FOR SERVICES AND TERMS OF PAYMENT The total price to cover all services described under the Scope of Work will be computed based on the unit prices shown in Table 1 and quantities of work completed as authorized by the OWNER including the lump sum tasks amounts being established by percent of completion. Tasks listed as "per each" or "L.F " are estimated. Quantities found in field investigation may vary and will be performed and charged by the unit price shown in Table 1 in an amount not to exceed the total proposal cost. Invoices will be rendered monthly and are due within thirty (30) days of receipt. Table 1 delineates the unit price for each task. VI. INFORMATION AND SERVICES TO BE PROVIDED BY THE OWNER. The Owner shall provide the following information and services: 1. CAD or ArcView map of the existing sewer system showing sewer lines, manholes, cleanouts, street right of ways, easements, and creeks and/or waterways within the Study Area. 2. Liaison with City officials to provide effective coordination and cooperation between the fire, police, utility departments and the Engineer, as necessary during execution of field work. 3. Access to manholes and lift stations. 4. Assistance by City personnel, knowledgeable of manhole and cleanout locations, in locating buried or hidden manholes or cleanouts. 5. Expose for entry, manholes that require excavation, cutting of pavement, and/or have lids fastened or frozen in place. 6. Water for cleaning unit from the city fire hydrants at no charge during cleaning, dyed -water flooding and quantification of leaks and CCTV tasks. 7. Disposal site for disposing of the debris removed from the sewer lines during the cleaning operation. 8. The necessary equipment and assistance as might be required to remove the specialized equipment (cleaning nozzle and hose, TV camera and coaxial cable, sewer plugs, mandrels, etc.) from the sewer should the equipment become lodged during the course of the work, and to complete line repair and restoration of the area. However, the City will not be responsible for damage to GSW W's equipment. Phase 4 Gtown Proposal Revl.doc Edward Aquifer Protection Plan City of Georgetown, Texas 11/9/2005 VII. TIME SCHEDULE The work being performed under this project shall be completed in seven months (with a final report due on August 31, 2006). VIII. NOTICE TO PROCEED The completion of the proposed work shall be contingent upon receipt of Authorization to Proceed by the OWNER and a signed copy of this proposal. GSWW, INC. Da 'd E. Koberlein, P.E. Associate Date Phase 4 Gtown Proposal Revl .doc 8 CITY OF GEORGETOWN, TEXAS Signature Title Date Table lase 3 Compensation City of Geo _ vn, Texas Edwards Aquifer I :tion Page 9 GSW W, Inc. City of Georgetown, Texas Phase 4 Project Compensation Task Description Unit Quantity Unit Price Total 100 Preparatory Work and Mobilization Lump Sum 1 $6,030.00 $6,030.00 200 Review of Existing Information Lump Sum 1 $1,500.00 $1,500.00 300 Public Awareness and Involvement Lump Sum 1 $2,450.00 $2,450.00 400 Smoke Testing Linear Foot 25,000 $0.33 $8,250.00 500 D ed Water Flooding/Leak Quantification and Evaluation Each 10 $185.00 $1,850.00 600 Night Flow Isolation Each 20 $210.00 $4,200.00 700 CCTV Internal Inspection(Total) Linear Foot 0 $0.00 700.1 4"-8" Diameter 0 $1.25 $0.00 700.2 10"-15" Diameter 0 $1.65 $0.00 700.3 18"-30" Diameter 0 $1.95 $0.00 800 Air Testing Each 10 $250.00 $2,500.00 900 Deflection Testing Each 10 $225.00 $2,250.00 1000 Infrared Camera Manhole Locations Linear Foot 10,000 $0.33 $3,300.00 1100 Data Management and Data Entry Asset/Form 1 1,000 $1.05 1 $1,050.00 1100 Project Administration, Management, Supervision, and QA/QC Each 1 $19,500.00 $19,500.00 1200 Data Evaluation, Analysis and Report Each 1 $18,250.00 $18,250.00 1300 Training Day 3 $1,200.00 $3,600.00 Total $74,730.00 Note: GUSto perform 100,000 If of smoke testing, CCTV work and all manhole inspections for this phase of the overall project. 11 Page 9 GSW W, Inc. Agenda Item: Agenda Item Check List rrti=1.: Financial Impact EARZ Phase IV Testing Agenda Item Subject: Consideration and possible recommendation to approve a contract between the City of Georgetown and GSWW, Inc for engineering services related to the fourth phase of the Edwards Aquifer Recharge Zone testing program and approve a budget of $74,730.00. Is this a Capital Improvement Yes (_) No Project: Council Date: 11/22/2005 link to Agenda database => Need Help? Was it budgeted? 0 Yes U No Is it within the approved budgeted amount? • Yes C) No If not, where is the money coming from? G/L Account Number 651-101-6618-00 Amount Going to Council $ 74,730.00 Is there something (budgeted) that won't get Yes 0 No done because you are spending these funds? If so, please explain. Will this have an impact on the next year's Yes • No budget? If so, please explain. Does this project have future revenue Yes No impact? Year: Department: If so, how? Identify all on-going costs (i.e., insurance, annual maintenance fees, licenses, operational costs, etc...). Estimated staff hours: Cross -divisional impact: Yes 0 No If so, what division(s)? Prepared by: Glenn DishongDate: 11/15/2005 WEERM Agenda Item Checklist., Approved on 1111612005 pprovers ride kssigned Notified eceived Status Changed Status Jim Briggs Assistant City 11/15/2005 11/15/2005 1/16/2005 11/16/2005 Approved Jose Lara Manager 11/16/2005 11/16/2005 1/16/2005 11/16/2005 Approved Utility Financial Analyst Approval Cycle Settings Council Meeting Date: November 22, 2005 Item No. AGENDA ITEM COVER SHEET SUBTECT: Consideration and possible action to amend the engineering contract with Kasberg, Patrick & Associates, for services relating to change in scope of the Southeast Arterial One (SE One) project. In the amount of $779,600.00 ITEM SUMMARY: -An amendment to the engineering contract with Kasberg, Patrick, & Associates (KPA), for services pertaining to the Southeast Arterial One alignment project is required. The original alignment had control points of Inner Loop and CR 110 east. With the selection of a new alignment a new amendment is needed for these Professional services. Staff and KPA is available to provide information pertaining to the projects history, and costs associated with the old and new alignments and the optional direct connect westbound SE One to westbound Inner Loop. Staff has carefully reviewed the contracts and work performed to date and are recommending the approval of the SE One Contract amendment. SPECIAL CONSIDERATIONS: At GTEC Board request engineering for the direct connect is optional may be deleted from the contract. FINANCIAL IMPACT: The approved amount to be deducted from 400.101-6022-00. GTEC BOARD RECOMMENDATION: GTEC Board recommended approval at the November 16, 2005 meeting 5-1 (Boecker abstains, Kirby absent) STAFF RECOMMENDATION: Staff recommends the contract amendm(nt for engineering services by CDM. COMMENTS: None ATTACHMENTS: 1. Proposed KPA contract amendment. Project Budget Submitted By: Thomas R. Benz P.E-Q,2) Systems Engineering Manager Ass for Utilities CITY OFGEORGETOWN SE ARTERIAL ONE Project Buget General Items Paving Streets & Paving Striping & Signage Elevated Structures (SE1 to Inner Loop Direct Connect) Seeding and Permanent Erosion Control Construction Total with Contigency (10%) $ 441,490.50 $ 4,403,223.00 $ 1,539,560.00 $ 212,888.50 $ 2,805,000.00 $ 133,375.00 $ 9,535,537.00 Right -Of -Way $ 1,360,000.00 Design Services $ 397,000.00 Contract Administration/Construction Services $ 206,500.00 Special Services $ 87,500.00 Optional Design Services (Structural Design of Direct Connect) $ 88,600.00 PROJECT BUDGET 11,675,137.00 AMENDMENT DATED NOVEMBER 4, 2005 TO THE AGREEMENT BETWEEN THE CITY OF GEORGETOWN AND KASBERG, PATRICK & ASSOCIATES, L.L.P. FOR PROFESSIONAL SERVICES FOR SOUTHEAST ARTERIAL ONE PROJECT The General Services Agreement between the CITY OF GEORGETOWN (City) and Kasberg, Patrick & Associates, L.L.P., (Engineer) last authorized on March 14, 1995, is hereby amended as follows: The scope and cost of the anticipated services are set forth in the attached Exhibit A. The charges for the work in Amendment dated November 4, 2005 are to be paid on a lump sum basis unless additional work due to change in scope is authorized. Your signatures below will constitute your acceptance of Amendment dated November 4, 2005. Executed in duplicate original this day of 2005 at Georgetown, Texas, where this contract is performable and enforceable. Approved as to form: Patricia E. Carls City Attorney Party of the First Part: CITY OF GEORGETOWN, TEXAS Gary Nelon Mayor Attest: Sandra D. Lee Party of the Second Part: City Secretary KASBERGRIgK &IATES, L.L.P.�r� By: R. Davidd Patrick, P.E. Principal Engineer STATE OF TEXAS COUNTY OF BELL This instrument as acknowledged before me on this the $4-h day of 1Vode;7t e f 2005. •� Printed name: Notary Public Commission Expires: 3;::g;•., =DORISM.LTERS I ZFNte ofTexasn Eplres ,H7, 2005 Exhibit A (Updated November 4, 2005) This updated Exhibit A to the original General Services Agreement between the City of Georgetown and Kasberg, Patrick & Associates, L.L.P., dated March 14, 1995, provides for the scope of engineering services required for developing design for the Southeast Arterial One Project. The attached letter details the services and associated charges for the proposed work. RICK N. KASI3ERCi. P.E. R. DAVID PATRICK, P.E. November 4, 2005 KASBERG, PATRICK CONSULTING ENGINEERS One South Main Temple, Texas 76501 (254) 773.3731 Mr. Jim Briggs Assistant City Manager City of Georgetown P.O. Box 409 Georgetown, Texas 78627-0409 Re: City of Georgetown Proposal for Southeast Arterial One Georgetown, Texas Dear Mr. Briggs: & ASSOCIATES, L.L.P. Fax (254) 773.6667 mail@ paengincers.com This letter proposal is in response to your request for basic and special engineering services required to provide construction drawings, bidding and construction administration for four lane roadway and drainage improvements for: The Southeast Arterial One Project The charges for this work are shown on Attachment "A" of this letter. We have priced the work according to the facts that we know about the project as of this date. Lump Sum charges are shown and will not change unless the scope of work is expanded, at which time we will meet with you and plan accordingly. The following are tasks that we have included in the work schedule: SCHEMATIC ENGINEERING PHASE. This phase involves developing schematic design and concepts of final design and evaluation in order to solidify design details for the final design phase. Services during this phase include: Identifying the governmental agencies that will have jurisdiction within and connecting to the project area. Meeting will be set with the entities to review the project scope and begin any permitting processes. Providing analyses of the CITY'S needs, planning surveys, and comparative evaluations of prospective sites and solutions. Mr. Jim Briggs November 4, 2005 Page Two 3. Providing a schematic opinion of probable cost of the CITY's requirements applicable to various alternatives. 4. Consulting with the CITY, reviewing preliminary reports, clarifying and defining the project requirements, reviewing available data, and discussing general scheduling. Conferences may also be required with approving and regulatory governmental agencies and affected utilities. 5. Advising the CITY as to whether additional data or services are required, and assisting the CITY in obtaining such data and services. 6. Analysis of existing connectivity of the roadway system. 7. Schematic design of the horizontal and vertical geometry of the proposed four lane roadway route including review of the parcel crossings and tributary crossings. 8. Schematic design of the storm water collection systems including conveyance to natural drainage systems and determination of water quality feature alternatives and sizing. 9. Schematic design of the roadway sections. 10. Schematic design for tributary crossings. IL Analysis of the final schematic of the connection of Southeast Inner Loop to the proposed SI -1130. 12. Analyze the phasing of a connection from Southeast Inner Loop to SH130 with future expansion to elevated intersection interchanges. Mr. Jim Briggs November 4. 2005 Page Three FINAL DESIGN PHASE. This phase of project development is undertaken only after the CITY has reviewed and approved the schematic engineering phase material. The basic services for the final design phase includes: Preparing construction drawings and specifications showing the character and extent of the project based on the accepted schematic engineering documents. 2. Preparing and furnishing to the CITY a revised opinion of probable costs based on the final drawings and specifications. Research and obtain regulatory permits from local, state, or federal authorities. This is distinguished from and does not include detailed applications and supporting documents for government grant-in-aid or planning grants that would be furnished as additional services. Fees for any local, state or federal construction permit applications are not included as part of the professional fee charges. These will be paid by the CITY. 4. Preparing basic documents related to construction contracts for review and approval by the CITY (and the CITY's legal and other advisors). These may include contract agreement forms, general conditions and supplementary conditions, invitations to bid, instructions to bidders, insurance and bonding requirements, and preparation of other contract -related documents. 5. Furnishing to the CITY the specified number of copies of drawings, specifications, and other contract documents. 6. Design the final schematic of the intersection and traffic flow of the proposed Southeast Arterial One and Southeast Inner Loop and the connection with SH 130. Design the final schematic of the intersection and traffic flow of the proposed Southeast Arterial One and Southeast Inner Loop and the connection with County Road 102. 8. Design the final schematic of the intersection and traffic flow of the proposed Southeast Arterial One and Southeast Inner Loop and the connection with County Road 104. 9. Design the final schematic of the intersection and traffic flow of the proposed Southeast Arterial One and Southeast Inner Loop and the connection with County Road 110. 10. Design the final schematic of the intersection and traffic flow of the proposed Southeast Arterial One and Southeast Inner Loop and the connection with Inner Loop. Mr. Jim Briggs November 4, 2005 Page Four 11. Completion of environmental, archaeological and geotechnical surveys and exploration for the four lane roadway. 12. Design surveys including the transfer of validated benchmarks to the proposed area with brass monuments at the proposed Rights -of -Way. 13. Design and submittal of WPAP reports to the TCEQ for project acceptance in the Re- charge Zone of the Edwards Aquifer. 14. Corps of Engineers submittal and acceptance excluding a mitigation plan and monitoring. 15. Meet regularly with the City of Georgetown Staff to review the progress of the design and coordinate any conflicts that arise. Mr. Jim Briggs November 4, 2005 Page Five SPECIFIC INFRASTRUCTURE DESIGN FEATURES FOR THE PROJECT • Final Design Schematics of the connection of SE Inner Loop and SH130 for the four lane roadway. • Project phasing for at grade intersections to elevated intersection interchanges. • Design surveys of the project site and topographical representation of the surveys. • Hydrology and drainage design for the four lane roadway. • WPAP reports to be submitted to the TCEQ for project acceptance. • Vertical geometry for both at grade intersections and elevated intersections of the four lane roadway. • Intersection design and signage for the four lane roadway. • Roadway striping and signage in accordance with TMUTCD. • Design of pull box and conduit system for future illumination. • Design of excess cut material for future elevated intersections. • Water quality feature design. • Environmental, archaeological and geotechnical surveys and investigations. • Corps of Engineer Nation -Wide Permits — It is assumed at this time that a 404 permit will be required for two streamways and a permit 39 for permanent loss of waters ofthe U.S. Although it can not be fully determined without investigation of the streamways and its natural vegetation. • Coordination with TX DOT and Williamson County. • Contract Documents and Specifications. If this proposal is agreeable, please return one executed originals to our office. Sincerely, R. David Patrick, P.E. RDP/crc ATTACHMENT A SUMMARY OF CHARGES FOR SERVICES 2005 —2006 CAPITAL IMPROVEMENTS PROJECT FOR THE SOUTHEAST ARTERIAL ONE PROJECT GEORGETOWN, TEXAS TASK The Southeast Arterial One Project I. BASIC SERVICES A. Final Design of the four lane roadway $ 95,800.00 B. Storm Water System for the four lane Roadway. $ 39,600.00 C. Connection to existing city and county roadways $ 69,500.00 D. Water Quality Systems for TCEQ $ 397700.00 E. Future Overpass Horizontal and Vertical Design of Southeast Inner Loop, CR 110, Direct Connects $ 74,600.00 F. Tributary Crossing Design $ 39,800.00 G. Connection to Existing Systems $ 38,000.00 TOTAL BASIC SERVICES $ 397,000.00 II. CONTRACT ADMIN/CONSTRUCTION SERVICES A. Bidding and Award $ 6,500.00 B. Control Staking $ 20,000.00 C. Construction Administration $ 180,000.00 TOTAL CONTRAT ADMIN SERVICES S 206,500.00 III. OPTIONAL DESIGN SERVICES A. Structural Design of Direct Connect $ 88,600.00 TOTAL OPTIONAL DESIGN SERVICES $ 88,600.00 IV. SPECIAL SERVICES A. Design Surveys $ 25,000.00 B. WPAP Design & Submittals $ 7,500.00 C. Archaeological Investigations $ 16,000.00 D. Environmental Investigations $ 15,000.00 E. Geotechnical Investigations S 14,000.00 F. Corps of Engineers Clearances S 10,000.00 TOTAL SPECIAL SERVICES S 87,500.00 Agenda Item Check List Financial Impact Agenda Item: Agenda Item Subject: Consideration and possible action to amend the engineering contract with Kasberg, Patrick & Associates, for services relating to change in scope of the Southeast Arterial One (SE One) project. In the amount of $779,600.00 Is this a Capital Improvement Project: Council Date: • Yes O No 11/22/2005 link to Agenda database => p Need Help? Was it budgeted? 0 Yes O No Is it within the approved budgeted amount? 0 Yes O No If not, where is the money coming from? G/L Account Number 400-101-6022-00 Amount Going to Council Is there something (budgeted) that won't get O Yes 0 No done because you are spending these funds? If so, please explain. Will this have an impact on the next year's O Yes 0 No budget? If so, please explain. Does this project have future revenue Yes • No impact? Year: Department: If so, how? Identify all on-going costs (i.e., insurance, annual maintenance fees, licenses, operational costs, etc...). Estimated staff hours: Cross -divisional impact: _i Yes 0 No If so, what division(s)? Prepared by: Tom Benz Date: 11/16/2005 Approval Cycle Settings Council Meeting Date: November 22, 2005 Item No. AGENDA ITEM COVER SHEET SUBJECT: First Reading of an Ordinance amending Section 10.12.090 of the Code of Ordinances relating to speed limits and speed zones; eliminating the school speed zone on Northwest Blvd. between Janis Drive and IH -35 Frontage Road; and adopting a school speed zone on Woodlake Drive between FM 2338 and Wildwood Drive. ITEM SUMMARY: In 1996, the Council established a school speed zone on the portion of Northwest Blvd. from Janis Drive to the southbound IH -35 frontage road to provide safer traffic conditions near two private schools formerly located on that segment of Northwest Blvd. The two private schools have since relocated, thereby, eliminating the need fora school speed zone along that segment of Northwest Blvd. A new elementary school is now located on Woodlake Drive between Williams Drive (FM 2338) and Wildwood Drive, thereby, necessitating the creation of a school speed zone on that segment of Woodlake Drive. The attached ordinance eliminates the above-described school speed zone on Northwest Blvd. and establishes a new school speed zone on the above-described segment of Woodlake Drive. Maps showing the portions of the impacted streets are attached. SPECIAL CONSIDERATIONS: None FINANCIAL IMPACT: None GUS BOARD RECOMMENDATION: N/A STAFF RECOMMENDATION: Recommend adoption. ATTACHMENTS: 1. Proposed ordinance 2. Exhibit showing Northwest Blvd. school speed zone to be eliminated and Woodlake Drive school speed zone to be established Limbi s, Mark Miller, Assistant i anager Transportation Services for Utilities Manager ORDINANCE NO. AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS, AMENDING SECTION 10.12.090 OF THE CODE OF ORDINANCES OF THE CITY OF GEORGETOWN, TEXAS RELATING TO SPEED LIMITS AND SPEED ZONES; ELIMINATING THE SCHOOL SPEED ZONE ON NORTHWEST BLVD. BETWEEN JANIS DRIVE AND IH -35 FRONTAGE ROAD; AND ADOPTING A SCHOOL SPEED ZONE ON WOODLAKE DRIVE BETWEEN FM 2338 AND WILDWOOD DRIVE; PROVIDING A CONFLICT CLAUSE; PROVIDING A SEVERABILITY CLAUSE; AND ESTABLISHING AN EFFECTIVE DATE. WHEREAS, in 1996, the City Council of the City of Georgetown, Texas, adopted an ordinance approving the modification of speed on Northwest Blvd to include a school zone because two private schools were located on Northwest Blvd; WHEREAS, the two private schools located on Northwest Blvd, between Janis Drive and IH -35 Frontage Road, have re -located and there has been a decrease in traffic on Northwest Blvd.; WHEREAS, a new elementary school is located on Woodlake Drive between FM 2338 and Wildwood Drive and there has been a significant increase in traffic around the new elementary school; and WHEREAS, the City Council of the City of Georgetown, Texas, hereby finds that it is necessary to eliminate the 20 -mph school speed zone along the entire length of Northwest Blvd. between Janis Drive and the IH -35 Frontage Road and necessary to adopt a 20 -mph school speed zone on Woodlake Drive between FM 2338 and Wildwood Drive. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GEORGETOWN, TEXAS, THAT: SECTION 1. The facts and recitations contained in the preamble of this ordinance are hereby found and declared to be true and correct, and are incorporated by reference herein and expressly made a part hereof, as if copied verbatim. The City Council hereby finds that this ordinance implements Century Plan Policy - Goals and Strategies Statement 9.0 which states: "Citizens and commercial goods move safely and efficiently throughout all parts of the City.", and further finds that the enactment of this ordinance is not inconsistent or in conflict with any other Century Plan Policies, as Ordinance No. Georgetown Code of Ordinances Amendment to Chapter 10.12.090 All City Streets. Page 1 of 3 required by Section 2.03 of the Administrative Chapter of the Policy Plan. SECTION 2. Chapter 10.12.090 of the Code of Ordinances of the City of Georgetown, Texas is hereby amended to read as follows: Sec. 10.12.090 All City Streets. B. 20 Mile Per Hour Zones. 26. School Speed Zone. Woodlake Drive. Beginning at a point 260 feet southwest of the west edge of FM 2338 and continuing southwest 900 feet, a prima facie maximum speed limit of 20 miles per hour during the hours of 7:15 a.m. until 8:15 a.m., and 2:45 p.m. until 3:45 p.m., when school is in session. SECTION 3. This ordinance shall be and is hereby declared to be cumulative of all other ordinances of the City of Georgetown, and this ordinance shall not operate to repeal or affect any of such other ordinances, except insofar as the provisions thereof might be inconsistent or in conflict with the provisions of this ordinance, in which event such conflicting provisions, if any in such other ordinance or ordinances are hereby superseded. SECTION 4. If any provision of this ordinance or application thereof to any person or circumstance, shall be held invalid, such invalidity shall not affect the other provisions, or application thereof, of this ordinance which can be given effect without the invalid provision or application, and to this end the provisions of this ordinance are hereby declared to be severable. SECTION 5. The Mayor is hereby authorized to sign this ordinance and the City Secretary to attest. This ordinance shall become effective and be in full force and effect ten (10) days on and after publication in accordance with the provisions of the Charter of the City of Georgetown. Ordinance No. Georgetown Code of Ordinances Amendment to Chapter 10. 12.090 All City Streets. Page 2 of 3 •... 26. School Speed Zone. Woodlake Drive. Beginning at a point 260 feet southwest of the west edge of FM 2338 and continuing southwest 900 feet, a prima facie maximum speed limit of 20 miles per hour during the hours of 7:15 a.m. until 8:15 a.m., and 2:45 p.m. until 3:45 p.m., when school is in session. SECTION 3. This ordinance shall be and is hereby declared to be cumulative of all other ordinances of the City of Georgetown, and this ordinance shall not operate to repeal or affect any of such other ordinances, except insofar as the provisions thereof might be inconsistent or in conflict with the provisions of this ordinance, in which event such conflicting provisions, if any in such other ordinance or ordinances are hereby superseded. SECTION 4. If any provision of this ordinance or application thereof to any person or circumstance, shall be held invalid, such invalidity shall not affect the other provisions, or application thereof, of this ordinance which can be given effect without the invalid provision or application, and to this end the provisions of this ordinance are hereby declared to be severable. SECTION 5. The Mayor is hereby authorized to sign this ordinance and the City Secretary to attest. This ordinance shall become effective and be in full force and effect ten (10) days on and after publication in accordance with the provisions of the Charter of the City of Georgetown. Ordinance No. Georgetown Code of Ordinances Amendment to Chapter 10. 12.090 All City Streets. Page 2 of 3 PASSED AND APPROVED on First Reading on the day of November, 2005. PASSED AND APPROVED on Second Reading on the _ day of December, 2005. ATTEST: THE CITY OF GEORGETOWN 0 Sandra D. Lee City Secretary APPROVED AS TO FORM: Patricia E. Carls, Brown & Cads, LLP City Attorney Ordinance No. Georgetown Code of Ordinances Amendment to Chapter 10. 12.090 All City Streets. Page 3 of 3 Gary Nelon, Mayor t SCHOOL SPEED ZONE EXHIBIT NOVEMBER 22, 2005 R YE N W+E S N WE + 41. R S F 4tiooR � t° i pp0 o°p �9?' OQ� 3 O° p J V, Q �/ \ AQP ad SPEED LIMIT ZONES - School Speed Limit Zone (To Be Added) School Speed Limit Zone (To Be Eliminated)� GEORGET�� OWN TEXAS